OBJECTIVES: To investigate the use of the GuideLiner "mother-and-child" guide catheter extension system as a simple solution to facilitate initial device delivery in balloon uncrossable chronic total occlusions (CTOs) undergoing percutaneous coronary intervention (PCI). BACKGROUND: During PCIs for CTO lesions, an important reason for procedural failure is the inability to deliver a balloon or microcatheter across the lesion. METHODS: We retrospectively accessed our interventional registry for 07/01/2010 to 03/21/2012 and extracted data on all CTO lesions involving GuideLiner catheter use. Cine review was performed to identify cases where a guidewire had crossed the CTO and the use of a GuideLiner catheter facilitated initial device delivery. RESULTS: We identified 28 patients that underwent PCI for CTO with a GuideLiner catheter used to assist initial balloon or microcatheter advancement across the culprit lesion. Mean overall CTO length was 26.3 ± 18.1 mm. The GuideLiner catheter was successful in delivering a small balloon to the CTO lesion in 85.7% of cases (24/28). A single CTO PCI resulted in a distal guidewire perforation, but there was no hemodynamic compromise or pericardial effusion and the patient was discharged the next day. Overall procedural success in these selected cases (where a guidewire had already crossed the CTO) was 89.3% (25/28). CONCLUSIONS: The GuideLiner mother-and-child catheter is a simple, safe and efficacious adjunctive device for difficult CTO PCIs where despite standard measures it is not possible to deliver an initial balloon or microcatheter across the occluded segment.
OBJECTIVES: To investigate the use of the GuideLiner "mother-and-child" guide catheter extension system as a simple solution to facilitate initial device delivery in balloon uncrossable chronic total occlusions (CTOs) undergoing percutaneous coronary intervention (PCI). BACKGROUND: During PCIs for CTO lesions, an important reason for procedural failure is the inability to deliver a balloon or microcatheter across the lesion. METHODS: We retrospectively accessed our interventional registry for 07/01/2010 to 03/21/2012 and extracted data on all CTO lesions involving GuideLiner catheter use. Cine review was performed to identify cases where a guidewire had crossed the CTO and the use of a GuideLiner catheter facilitated initial device delivery. RESULTS: We identified 28 patients that underwent PCI for CTO with a GuideLiner catheter used to assist initial balloon or microcatheter advancement across the culprit lesion. Mean overall CTO length was 26.3 ± 18.1 mm. The GuideLiner catheter was successful in delivering a small balloon to the CTO lesion in 85.7% of cases (24/28). A single CTO PCI resulted in a distal guidewire perforation, but there was no hemodynamic compromise or pericardial effusion and the patient was discharged the next day. Overall procedural success in these selected cases (where a guidewire had already crossed the CTO) was 89.3% (25/28). CONCLUSIONS: The GuideLiner mother-and-child catheter is a simple, safe and efficacious adjunctive device for difficult CTO PCIs where despite standard measures it is not possible to deliver an initial balloon or microcatheter across the occluded segment.
Authors: Peter Tajti; Iosif Xenogiannis; Dimitris Karmpaliotis; Khaldoon Alaswad; Farouc A Jaffer; M Nicholas Burke; Imre Ungi; Emmanouil S Brilakis Journal: Curr Cardiol Rep Date: 2018-10-22 Impact factor: 2.931
Authors: Jan-Erik Guelker; Christian Blockhaus; Knut Kroeger; Rosemarie Wehner; Heinrich Klues; Alexander Bufe Journal: J Saudi Heart Assoc Date: 2017-09-11