| Literature DB >> 23940058 |
Justin J Konkle, Patrick W Goodwill, Emine Ulku Saritas, Bo Zheng, Kuan Lu, Steven M Conolly.
Abstract
We experimentally demonstrate a 20-fold improvement in acquisition time in projection reconstruction (PR) magnetic particle imaging (MPI) relative to the state-of-the-art PR MPI imaging results. We achieve this acceleration in our imaging system by introducing an additional Helmholtz electromagnet pair, which creates a slow shift (focus) field. Because of magnetostimulation limits in humans, we show that scan time with three-dimensional (3D) PR MPI is theoretically within the same order of magnitude as 3D MPI with a field free point; however, PR MPI has an order of magnitude signal-to-noise ratio gain.Entities:
Mesh:
Substances:
Year: 2013 PMID: 23940058 PMCID: PMC4096315 DOI: 10.1515/bmt-2012-0062
Source DB: PubMed Journal: Biomed Tech (Berl) ISSN: 0013-5585 Impact factor: 1.411