| Literature DB >> 23938145 |
Anders M Karlsen1, Oyvind Thomassen, Bjarne H Vikenes, Guttorm Brattebø.
Abstract
INTRODUCTION: Hypothermia is associated with increased morbidity and mortality in trauma patients and poses a challenge in pre-hospital treatment. The aim of this study was to identify equipment to prevent, diagnose, and treat hypothermia in Norwegian pre-hospital services.Entities:
Mesh:
Year: 2013 PMID: 23938145 PMCID: PMC3751018 DOI: 10.1186/1757-7241-21-63
Source DB: PubMed Journal: Scand J Trauma Resusc Emerg Med ISSN: 1757-7241 Impact factor: 2.953
Respondents
| Ambulance services | 18 | 512 |
| Fixed wing air ambulance | 7 | 9 |
| Helicopter air ambulance | 11 | 12 |
| Rescue service | 6 | 10 |
Equipment to prevent, diagnose and treat hypothermia in Norway
| | ||||
|---|---|---|---|---|
| | ||||
| Space blankets | 151 (29) | 5 (56) | 8 (67) | 0 |
| Hospital duvets | 468 (91) | 9 (100) | 11 (92) | 10 (100) |
| Cotton blankets | 436 (85) | 7 (78) | 7 (58) | 2 (20) |
| Plastic “bubble wrap” | 428 (84) | 0 | 12 (100) | 10 (100) |
| Wool blankets | 154 (30) | 9 (100) | 2 (17) | 9 (90) |
| Sleeping bags | 0 | 0 | 0 | 0 |
| Shelter bags (not insulated) | 0 | 0 | 0 | 0 |
| Insulated shelter bags | 0 | 0 | 2 (17) | 10 (100) |
| Separate head cover | 220 (43) | 0 | 7 (58) | 10 (100) |
| Body bags | 512 (100) | 0 | 0 | 10 (100) |
| Plastic covers | 0 | 1 (11) | 0 | 0 |
| Othera | 148 (29) | 0 | 0 | 0 |
| 72 (14) | 4 (44) | 7 (58) | 7 (70) | |
| Chemical heat pads | 57 (11) | 4 (44) | 7 (58) | 5 (50) |
| Water bottles | 0 | 0 | 0 | 5 (50) |
| Electrical heating blankets | 0 | 0 | 4 (33) | 0 |
| Forced air warmer | 0 | 0 | 2 (17) | 0 |
| Warm i.v. fluid protocol | 15 (3) | 0 | 0 | 0 |
| Other | 0 | 0 | 0 | 0 |
| 373 (73) | 2 (22) | 5 (42) | 7 (70) | |
| Yes | 61 (12) | 7 (100) | 12 (100) | 10 (100) |
| Not sure | 123 (24) | 0 | 0 | 0 |
| For rectal use | 61 (100)b | 7 (100) | 12 (100) | 8 (80) |
| For oesophageal use | 0 | 7 (100) | 12 (100) | 8 (80) |
| For tympanic use | 46 (75)b | 0 | 0 | 2 (20) |
| For oral use | 0 (0)b | 1 (11) | 0 | 0 |
| For axillary use | 0 (0)b | 3 (33) | 0 | 0 |
| Otherd | 0 | 4 (44) | 0 | 3 (30) |
| 468 (91) | 1 (11) | 11 (92)c | 10 (100) | |
| 15 (3) | 0 | 2 (17) | 2 (20) | |
aBlizzard® rescue blanket, vacuum mattresses.
bNumber and percentage of units represented in “Yes” category (n = 61).
cHEMS fluids are kept warm in storage lockers at the base, not in the helicopter unit.
dBladder, skin.