Literature DB >> 23936735

Clinical outcomes of distal femoral fractures in the geriatric population using locking plates with a minimally invasive approach.

Hitendra K Doshi1, Png Wenxian, Maitra Vaarun Burgula, Diarmuid Paul Murphy.   

Abstract

BACKGROUND: Fractures of the distal femur comprise 4% to 6% of all femoral fractures. Elderly patients are predisposed to low-energy fractures due to osteoporosis. Treatment of these fractures in the elderly group remains a challenge. Our hypothesis is that locking plates inserted with minimally invasive plate osteosynthesis (MIPO) techniques will produce better results compared to those inserted by open technique. The objective of this study is to evaluate the clinical outcomes of MIPO technique using locking plates in the elderly patients.
MATERIALS AND METHODS: A total of 24 elderly patients (mean age 73 years) with distal femur fractures treated using the MIPO technique (2007-2010) were reviewed retrospectively. Parameters analyzed included classification of fracture, time to fracture union, knee range of motion, functional knee score (Knee Society Score-Functional) at 6 months, and other significant complications. One patient was lost to follow-up.
RESULTS: In all, 88% of the fractures were extraarticular. The mean time to union was 13.48 (range: 8-28) weeks. Mean range of motion achieved at 6 months and beyond was 100° ranging from 0 to 30 (extension) to 90 to 140 (flexion). Functional knee scores at 6 months from fixation were satisfactory (mean score 88.8). There were no cases of implant failure, nonunion, and infection. In all, 6 (25%) patients developed deep vein thrombosis (DVT) in the early postoperative period, all of which were below the level of the knee joint.
CONCLUSION: Locking plates inserted using MIPO techniques in elderly patients with distal femur fractures appear to be promising based on clinical outcome measurements. However, there was a high incidence of DVT noted.

Entities:  

Keywords:  distal femur fracture; geriatric population; locking plates; minimally invasive

Year:  2013        PMID: 23936735      PMCID: PMC3739411          DOI: 10.1177/2151458513496254

Source DB:  PubMed          Journal:  Geriatr Orthop Surg Rehabil        ISSN: 2151-4585


  25 in total

Review 1.  The development of the distal femur Less Invasive Stabilization System (LISS).

Authors:  R Frigg; A Appenzeller; R Christensen; A Frenk; S Gilbert; R Schavan
Journal:  Injury       Date:  2001-12       Impact factor: 2.586

Review 2.  Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology.

Authors:  Stephan M Perren
Journal:  J Bone Joint Surg Br       Date:  2002-11

3.  Functional outcome and mortality in geriatric distal femoral fractures.

Authors:  C Kammerlander; P Riedmüller; M Gosch; M Zegg; U Kammerlander-Knauer; R Schmid; T Roth
Journal:  Injury       Date:  2012-03-08       Impact factor: 2.586

4.  Choosing a proper working length can improve the lifespan of locked plates. A biomechanical study.

Authors:  Konrad L Hoffmeier; Gunther O Hofmann; Thomas Mückley
Journal:  Clin Biomech (Bristol, Avon)       Date:  2010-12-24       Impact factor: 2.063

Review 5.  Systematic review and meta-analysis on the rate of postoperative venous thromboembolism in orthopaedic surgery in Asian patients without thromboprophylaxis.

Authors:  B Kanchanabat; W Stapanavatr; S Meknavin; C Soorapanth; C Sumanasrethakul; P Kanchanasuttirak
Journal:  Br J Surg       Date:  2011-06-14       Impact factor: 6.939

6.  Biomechanical principles and mechanobiologic aspects of flexible and locked plating.

Authors:  Lutz Claes
Journal:  J Orthop Trauma       Date:  2011-02       Impact factor: 2.512

7.  Early results of the less invasive stabilization system for mechanically unstable fractures of the distal femur (AO/OTA types A2, A3, C2, and C3).

Authors:  Mark Weight; Cory Collinge
Journal:  J Orthop Trauma       Date:  2004-09       Impact factor: 2.512

Review 8.  Biomechanics of locked plates and screws.

Authors:  Kenneth A Egol; Erik N Kubiak; Eric Fulkerson; Frederick J Kummer; Kenneth J Koval
Journal:  J Orthop Trauma       Date:  2004-09       Impact factor: 2.512

9.  Epidemiology of diaphyseal and distal femoral fractures in Rochester, Minnesota, 1965-1984.

Authors:  T J Arneson; L J Melton; D G Lewallen; W M O'Fallon
Journal:  Clin Orthop Relat Res       Date:  1988-09       Impact factor: 4.176

10.  Is routine thromboprophylaxis justified among Indian patients sustaining major orthopedic trauma? A systematic review.

Authors:  Ramesh K Sen; Sujit K Tripathy; Amit K Singh
Journal:  Indian J Orthop       Date:  2011-05       Impact factor: 1.251

View more
  13 in total

1.  Incidence of nonunion after surgery of distal femoral fractures using contemporary fixation device: a meta-analysis.

Authors:  Byung-Ho Yoon; In Keun Park; Youngwoo Kim; Hyoung-Keun Oh; Suk Kyu Choo; Yerl-Bo Sung
Journal:  Arch Orthop Trauma Surg       Date:  2020-05-09       Impact factor: 3.067

2.  Results of treatment of distal extra: articular femur fractures with locking plates using minimally invasive approach--experience with 25 consecutive geriatric patients.

Authors:  O Khursheed; M M Wani; S Rashid; A H Lone; Q Manaan; A Sultan; R A Bhat; B A Mir; M A Halwai; N Akhter
Journal:  Musculoskelet Surg       Date:  2014-12-14

Review 3.  Outcomes of Primary Total Knee Arthroplasty in Fractures Around the Knee in the Elderly: A Systematic Review and Pooled Analysis of 212 Patients Across 11 Studies.

Authors:  Parth Bansal; Prasoon Kumar; Karan Jindal; Vishal Kumar; Sameer Aggarwal; Mandeep S Dhillon
Journal:  Indian J Orthop       Date:  2021-12-01       Impact factor: 1.251

Review 4.  Locking plate fixation of distal femoral fractures is a challenging technique: a retrospective review.

Authors:  Giuseppe Toro; Giampiero Calabrò; Antonio Toro; Alessandro de Sire; Giovanni Iolascon
Journal:  Clin Cases Miner Bone Metab       Date:  2016-04-07

5.  Perioperative adverse events in distal femur fractures treated with intramedullary nail versus plate and screw fixation.

Authors:  Christian A Pean; Sanjit R Konda; Adam C Fields; Anthony Christiano; Kenneth A Egol
Journal:  J Orthop       Date:  2015-11-01

6.  Comparing Intramedullary Nailing Versus Locked Plating in the Treatment of Native Distal Femur Fractures: Is One Superior to the Other?

Authors:  Jaclyn M Jankowski; Patrick F Szukics; Jay K Shah; David M Keller; Robinson E Pires; Frank A Liporace; Richard S Yoon
Journal:  Indian J Orthop       Date:  2021-01-13       Impact factor: 1.251

7.  Effects of a Pasty Bone Cement Containing Brain-Derived Neurotrophic Factor-Functionalized Mesoporous Bioactive Glass Particles on Metaphyseal Healing in a New Murine Osteoporotic Fracture Model.

Authors:  Vivien Kauschke; Maike Schneider; Annika Jauch; Matthias Schumacher; Marian Kampschulte; Marcus Rohnke; Anja Henss; Coralie Bamberg; Katja Trinkaus; Michael Gelinsky; Christian Heiss; Katrin Susanne Lips
Journal:  Int J Mol Sci       Date:  2018-11-09       Impact factor: 5.923

8.  Single-Incision Double-Plating Approach in the Management of Isolated, Closed Osteoporotic Distal Femoral Fractures.

Authors:  Radwan G Metwaly; Zeiad M Zakaria
Journal:  Geriatr Orthop Surg Rehabil       Date:  2018-11-11

9.  Analysis of the occurrence of deep venous thrombosis in lower extremity fractures: A clinical study.

Authors:  Qiang Li; Xiao Chen; Yuanyuan Wang; Lin Li
Journal:  Pak J Med Sci       Date:  2018 Jul-Aug       Impact factor: 1.088

10.  Management of AO type 12C humerus proximal metadiaphyseal fractures with minimally invasive plate osteosynthesis in geriatric patients.

Authors:  Firat Seyfettinoğlu; Hasan Ulaş Oğur; Ümit Tuhanioğlu; Hakan Çiçek; Ahmet Kapukaya
Journal:  Clin Interv Aging       Date:  2018-05-22       Impact factor: 4.458

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.