Literature DB >> 23934665

On Artifact-Free Projection Overlaps in Multi-Pinhole Tomographic Imaging.

.   

Abstract

In multi-pinhole SPECT, overlapping the projections from different pinholes has been used to increase sensitivity. However, the prevailing view is that the overall quality of the reconstructed image is not improved by the overlaps in the projections. It is often stated in literatures that overlaps introduce ambiguous information, which can lead to nonuniqueness of solution for the inverse problem, and thus artifacts are introduced in the reconstructed image. On the other hand, contrary to the prevailing view, a recent study on slit-slat collimators shows that artifacts can be removed with the "help" of an extra complete nonoverlapped projection data set. In this paper, two types of artifact-free projection overlaps are defined in general, and the criteria for designing artifact-free multi-pinhole systems with overlaps are proposed. It is shown that once the criteria are satisfied, the solution of the inverse problem is unique, and thus no artifact is expected in the reconstructed image. Via extensive simulation study, various artifact-free overlapping multi-pinhole systems are designed and validated. It is shown that overlaps in the artifact-free systems can improve contrast-to-noise ratio (CNR). With a proper design, the CNR for an artifact-free overlapping system can be significantly higher than that for the corresponding nonoverlapping system. The improved image quality is also confirmed with noisy reconstructions.

Year:  2013        PMID: 23934665     DOI: 10.1109/TMI.2013.2277588

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  4 in total

Review 1.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

2.  Design of a Multi-Pinhole Collimator for I-123 DaTscan Imaging on Dual-Headed SPECT Systems in Combination with a Fan-Beam Collimator.

Authors:  Michael A King; Joyeeta M Mukherjee; Arda Könik; I George Zubal; Joyoni Dey; Robert Licho
Journal:  IEEE Trans Nucl Sci       Date:  2016-02-03       Impact factor: 1.679

3.  Reducing multiplexing artifacts in multi-pinhole SPECT with a stacked silicon-germanium system: a simulation study.

Authors:  Lindsay C Johnson; Sepideh Shokouhi; Todd E Peterson
Journal:  IEEE Trans Med Imaging       Date:  2014-07-17       Impact factor: 10.048

4.  Longitudinal in vivo evaluation of bone regeneration by combined measurement of multi-pinhole SPECT and micro-CT for tissue engineering.

Authors:  Philipp S Lienemann; Stéphanie Metzger; Anna-Sofia Kiveliö; Alain Blanc; Panagiota Papageorgiou; Alberto Astolfo; Bernd R Pinzer; Paolo Cinelli; Franz E Weber; Roger Schibli; Martin Béhé; Martin Ehrbar
Journal:  Sci Rep       Date:  2015-05-19       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.