Literature DB >> 23927051

Optical performance of two new trifocal intraocular lenses: through-focus modulation transfer function and influence of pupil size.

Javier Ruiz-Alcocer1, David Madrid-Costa, Santiago García-Lázaro, Teresa Ferrer-Blasco, Robert Montés-Micó.   

Abstract

BACKGROUND: To compare the in vitro optical quality of two new trifocal intraocular lenses at different focal points as a function of pupil size.
METHODS: Two intraocular lenses having different design approaches were evaluated: the AT LISA tri 839MP with a trifocal diffractive design, and the FineVision, which combines two distinct apodized bifocal diffractive profiles resulting in three foci. A PMTF optical bench was used to assess the intraocular lenses' performance, and as optical quality metrics, the through-focus modulation transfer function was selected; that is, it was measured at 10 focal points and for four different apertures (2.0, 3.0, 3.75 and 4.5 mm).
RESULTS: For both lenses, the through-focus curve showed three peaks, corresponding to far, intermediate and near focal point. At the 0.0 D focal point, the FineVision yielded better results for larger pupils. At the -1.5 D focal point, both lenses performed worse for larger pupils. At the -3.0 D, the FineVision provided better results for all apertures. However, at the -3.5 D focal point, it was the AT LISA tri 839MP that outperformed the FineVision for larger pupils.
CONCLUSIONS: The two trifocal intraocular lenses under analysis have modulation transfer function peaks that correspond to the far, intermediate and near focal points. For larger pupil sizes, the FineVision seems to provide better results at far focal points, while the AT LISA tri 839MP not only provides better results at the intermediate and near focal points, but is also less pupil size-dependent.
© 2013 Royal Australian and New Zealand College of Ophthalmologists.

Keywords:  optical bench; pupillary size; trifocal intraocular lens

Mesh:

Year:  2013        PMID: 23927051     DOI: 10.1111/ceo.12181

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  10 in total

1.  [Optical quality of three trifocal intraocular lens models : An optical bench comparison].

Authors:  R Khoramnia; T M Yildirim; T Tandogan; S Liebing; G Łabuz; C Y Choi; G Auffarth
Journal:  Ophthalmologe       Date:  2018-01       Impact factor: 1.059

2.  Model of the light sword intraocular lens: in-vitro comparative studies.

Authors:  Krzysztof Petelczyc; Andrzej Kolodziejczyk; Narcyz Błocki; Anna Byszewska; Zbigniew Jaroszewicz; Karol Kakarenko; Katarzyna Kołacz; Michał Miler; Alejandro Mira-Agudelo; Walter Torres-Sepúlveda; Marek Rękas
Journal:  Biomed Opt Express       Date:  2019-12-04       Impact factor: 3.732

3.  Method for the generation and visualization of cross-sectional images of three-dimensional point spread functions for rotationally symmetric intraocular lenses.

Authors:  Jan Sievers; Ricardo Elsner; Sebastian Bohn; Melanie Schünemann; Heinrich Stolz; Rudolf F Guthoff; Oliver Stachs; Karsten Sperlich
Journal:  Biomed Opt Express       Date:  2022-02-01       Impact factor: 3.732

Review 4.  Opto-Mechanical Eye Models, a Review on Human Vision Applications and Perspectives for Use in Industry.

Authors:  André Rino Amorim; Boris Bret; José M González-Méijome
Journal:  Sensors (Basel)       Date:  2022-10-10       Impact factor: 3.847

5.  Optical bench performance of AcrySof(®) IQ ReSTOR(®), AT LISA(®) tri, and FineVision(®) intraocular lenses.

Authors:  Daniel Carson; Warren E Hill; Xin Hong; Mutlu Karakelle
Journal:  Clin Ophthalmol       Date:  2014-10-14

6.  In vitro optical quality measurements of three intraocular lens models having identical platform.

Authors:  Hyeck Soo Son; Tamer Tandogan; Stephanie Liebing; Patrick Merz; Chul Young Choi; Ramin Khoramnia; Gerd U Auffarth
Journal:  BMC Ophthalmol       Date:  2017-06-29       Impact factor: 2.209

7.  Visual and refractive outcomes following implantation of a new trifocal intraocular lens.

Authors:  Michael Lawless; Chris Hodge; Joe Reich; Lewis Levitz; Uday K Bhatt; Colm McAlinden; Kate Roberts; Timothy V Roberts
Journal:  Eye Vis (Lond)       Date:  2017-04-04

8.  Presbyopia-correcting performance and subjective outcomes of a trifocal intraocular lens in eyes with different axial lengths: A prospective cohort study.

Authors:  Tong Sun; Yiyun Liu; Xiaorui Zhao; Yufei Gao; Tingting Yang; Qianqian Lan; Chuhao Tang; Hong Qi
Journal:  Front Med (Lausanne)       Date:  2022-09-02

9.  Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens.

Authors:  Shinwook Lee; Myoung Choi; Zaiwei Xu; Zeyu Zhao; Elsinore Alexander; Yueai Liu
Journal:  Clin Ophthalmol       Date:  2016-06-02

10.  Comparison of clinical performance between trifocal and bifocal intraocular lenses: A meta-analysis.

Authors:  Zequan Xu; Danmin Cao; Xu Chen; Song Wu; Xin Wang; Qiang Wu
Journal:  PLoS One       Date:  2017-10-26       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.