A DANTE tagging sequence for the evaluation of translational sample motion.

T J Mosher1, M B Smith.   

Abstract

A magnetic resonance imaging sequence that is sensitive to translational motion such as that seen with cardiac contraction is presented. The sequence employs DANTE radio-frequency excitation with a continuous magnetic field gradient to generate a grid pattern of lines. There is improved line resolution and reduced eddy-current formation over current techniques.

Entities:  

Mesh:

Year:  1990        PMID: 2392056     DOI: 10.1002/mrm.1910150215

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  31 in total

Review 1.  Quantitative tagged magnetic resonance imaging of the normal human left ventricle.

Authors:  C C Moore; E R McVeigh; E A Zerhouni
Journal:  Top Magn Reson Imaging       Date:  2000-12

2.  Multi-echo segmented k-space imaging: an optimized hybrid sequence for ultrafast cardiac imaging.

Authors:  S B Reeder; E Atalar; A Z Faranesh; E R McVeigh
Journal:  Magn Reson Med       Date:  1999-02       Impact factor: 4.668

3.  Left ventricular motion reconstruction from planar tagged MR images: a comparison.

Authors:  J Declerck; T S Denney; C Oztürk; W O'Dell; E R McVeigh
Journal:  Phys Med Biol       Date:  2000-06       Impact factor: 3.609

4.  Four-dimensional B-spline based motion analysis of tagged MR images: introduction and in vivo validation.

Authors:  C Ozturk; E R McVeigh
Journal:  Phys Med Biol       Date:  2000-06       Impact factor: 3.609

Review 5.  Cardiovascular nuclear magnetic resonance: basic and clinical applications.

Authors:  John R Forder; Gerald M Pohost
Journal:  J Clin Invest       Date:  2003-06       Impact factor: 14.808

6.  Cardiac tagging with breath-hold cine MRI.

Authors:  E R McVeigh; E Atalar
Journal:  Magn Reson Med       Date:  1992-12       Impact factor: 4.668

7.  Calculation of three-dimensional left ventricular strains from biplanar tagged MR images.

Authors:  C C Moore; W G O'Dell; E R McVeigh; E A Zerhouni
Journal:  J Magn Reson Imaging       Date:  1992 Mar-Apr       Impact factor: 4.813

8.  Myocardial tagging with steady state free precession techniques and semi-automatic postprocessing--impact on diagnostic value.

Authors:  Thorsten R C Johnson; Nicole Bayrhof; Armin Huber; Joost P A Kuijer; Roger Luechinger; Olaf Dietrich; Dietrich Stoevesandt; Dorthe Pedersen; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2007-04-19       Impact factor: 5.315

9.  Noninvasive measurement of transmural gradients in myocardial strain with MR imaging.

Authors:  E R McVeigh; E A Zerhouni
Journal:  Radiology       Date:  1991-09       Impact factor: 11.105

10.  Estimating Motion From MRI Data.

Authors:  Cengizhan Ozturk; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2003-10       Impact factor: 10.961

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.