Tear film images and breakup analyzed using fluorescent quenching.

P Ewen King-Smith1, Padmapriya Ramamoorthy, Richard J Braun, Jason J Nichols.   

Abstract

PURPOSE: Tear evaporation should increase fluorescein concentration, causing fluorescence dimming from self-quenching for high but not low fluorescein concentration. This prediction was tested and compared to the predicted effect of "tangential flow" that fluorescence dimming should be similar for high and low concentrations.
METHODS: A custom optical system was used for video recording of tear film fluorescence in 30 subjects. The subjects were asked to blink at the start of the recording and try to keep their eyes open for the rest of the 60-second recording. An initial recording was made after instillation of 1 μL 0.1% fluorescein followed by further recordings at 5-minute intervals using 0.5% and 5% fluorescein.
RESULTS: Decay of fluorescence was considerably greater for the high (5%) concentration condition than for the low (0.1%) concentration. This is shown by "ratio images" (ratio of the intensity of a fluorescence image at a later time divided by that of an earlier image), fluorescence decay curves, fluorescence decay rates, and histograms of estimated tear thickness decrease. For example, for the high concentration condition, decay rates were higher than for the low concentration for all 30 subjects (P < 0.0001, binomial test). Additionally, breakup time was significantly reduced for the high compared to the low concentration condition.
CONCLUSIONS: The greater fluorescence decay and more rapid breakup for the high concentration condition are the results expected if thinning and breakup are mainly due to evaporation, hence causing self-quenching. Fluorescence decay rate for the low concentration condition was not significantly greater than zero.

Entities:  

Keywords:  breakup; evaporation; fluorescence; quenching; tangential flow

Mesh:

Substances:

Year:  2013        PMID: 23920365      PMCID: PMC3771556          DOI: 10.1167/iovs.13-12628

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  30 in total

1.  Alternative reference values for tear film break up time in normal and dry eye populations.

Authors:  Mark B Abelson; George W Ousler; Lauren A Nally; Donna Welch; Kathleen Krenzer
Journal:  Adv Exp Med Biol       Date:  2002       Impact factor: 2.622

Review 2.  Grading of corneal and conjunctival staining in the context of other dry eye tests.

Authors:  Anthony J Bron; Victoria E Evans; Janine A Smith
Journal:  Cornea       Date:  2003-10       Impact factor: 2.651

3.  Meibomian keratoconjunctivitis.

Authors:  J P McCulley; G F Sciallis
Journal:  Am J Ophthalmol       Date:  1977-12       Impact factor: 5.258

4.  Tear film breakup and structure studied by simultaneous video recording of fluorescence and tear film lipid layer images.

Authors:  P Ewen King-Smith; Kathleen S Reuter; Richard J Braun; Jason J Nichols; Kelly K Nichols
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-07-22       Impact factor: 4.799

5.  Desiccation of the precorneal film. I. Corneal wetting-time.

Authors:  M S Norn
Journal:  Acta Ophthalmol (Copenh)       Date:  1969

6.  A surface tension gradient mechanism for driving the pre-corneal tear film after a blink.

Authors:  R E Berger; S Corrsin
Journal:  J Biomech       Date:  1974-05       Impact factor: 2.712

7.  Interpretation of tear film breakup.

Authors:  G T Vanley; I H Leopold; T H Gregg
Journal:  Arch Ophthalmol       Date:  1977-03

8.  Determination of tear volume and tear flow.

Authors:  S Mishima; A Gasset; S D Klyce; J L Baum
Journal:  Invest Ophthalmol       Date:  1966-06

9.  Fluorescein. Physiochemical factors affecting its fluorescence.

Authors:  K G Romanchuk
Journal:  Surv Ophthalmol       Date:  1982 Mar-Apr       Impact factor: 6.048

10.  The repeatability of clinical measurements of dry eye.

Authors:  Kelly K Nichols; G Lynn Mitchell; Karla Zadnik
Journal:  Cornea       Date:  2004-04       Impact factor: 2.651

View more
  18 in total

1.  Fluorescence lifetime imaging microscopy reveals quenching of fluorescein within corneal epithelium.

Authors:  Ben J Glasgow
Journal:  Exp Eye Res       Date:  2016-04-20       Impact factor: 3.467

Review 2.  Dynamics and function of the tear film in relation to the blink cycle.

Authors:  R J Braun; P E King-Smith; C G Begley; Longfei Li; N R Gewecke
Journal:  Prog Retin Eye Res       Date:  2014-12-03       Impact factor: 21.198

Review 3.  TFOS DEWS II Tear Film Report.

Authors:  Mark D P Willcox; Pablo Argüeso; Georgi A Georgiev; Juha M Holopainen; Gordon W Laurie; Tom J Millar; Eric B Papas; Jannick P Rolland; Tannin A Schmidt; Ulrike Stahl; Tatiana Suarez; Lakshman N Subbaraman; Omür Ö Uçakhan; Lyndon Jones
Journal:  Ocul Surf       Date:  2017-07-20       Impact factor: 5.033

4.  Tear film dynamics with evaporation, wetting, and time-dependent flux boundary condition on an eye-shaped domain.

Authors:  Longfei Li; R J Braun; K L Maki; W D Henshaw; P E King-Smith
Journal:  Phys Fluids (1994)       Date:  2014-05-06       Impact factor: 3.521

5.  Mathematical modelling of glob-driven tear film breakup.

Authors:  L Zhong; C F Ketelaar; R J Braun; C G Begley; P E King-Smith
Journal:  Math Med Biol       Date:  2019-03-14       Impact factor: 1.854

6.  On tear film breakup (TBU): dynamics and imaging.

Authors:  Richard J Braun; Tobin A Driscoll; Carolyn G Begley; P Ewen King-Smith; Javed I Siddique
Journal:  Math Med Biol       Date:  2018-06-13       Impact factor: 1.854

7.  Dynamics of Fluorescent Imaging for Rapid Tear Thinning.

Authors:  L Zhong; R J Braun; C G Begley; P E King-Smith
Journal:  Bull Math Biol       Date:  2018-10-15       Impact factor: 1.758

Review 8.  Mechanisms, imaging and structure of tear film breakup.

Authors:  P Ewen King-Smith; Carolyn G Begley; Richard J Braun
Journal:  Ocul Surf       Date:  2017-09-20       Impact factor: 5.033

9.  Computed tear film and osmolarity dynamics on an eye-shaped domain.

Authors:  Longfei Li; Richard J Braun; Tobin A Driscoll; William D Henshaw; Jeffrey W Banks; P Ewen King-Smith
Journal:  Math Med Biol       Date:  2015-04-15       Impact factor: 1.854

10.  Reliability and efficacy of maximum fluorescein tear break-up time in diagnosing dry eye disease.

Authors:  Yujie Mou; Huan Xiang; Lin Lin; Kelan Yuan; Xin Wang; Yaying Wu; Jinjin Min; Xiuming Jin
Journal:  Sci Rep       Date:  2021-06-01       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.