Three-dimensional kinematics of the human back.

R J Hindle1, M J Pearcy, A T Cross, D H Miller.   

Abstract

This study examined the use of a new device, the 3space isotrak, to measure the kinematic behaviour of the backs of normal subjects and of patients from two orthopaedic practices. The device was shown to measure angles with a root mean square error of less than 0.2° and individuals showed a maximum standard deviation from the mean of movements repeated five times of less than 4°. Eighty normal subjects both male and female in four age ranges 20-29, 30-39, 40-49 and 50 years and over were measured. The three-dimensional kinematic patterns were similar for all groups, showing normals to have clearly identified patterns of movement. A general trend for decreasing mobility with age and some sex differences were also demonstrated. The clinical series showed widespread disruption to the primary and coupled movements of all the patients. When grouped together by clinical diagnosis the patient groups showed evidence of discrete and identifiable alterations from the normal kinematic patterns. However, further studies of homogeneous patient groups are required in order to demonstrate whether the measurements are of actual clinical use. The clinical studies also demonstrated that clinical subjective assessment of back mobility bore little relation to the true movements and therefore the clinical measurement of back movements should be reassessed. This study has shown the 3space isotrak to be an effective tool in the clinic for the three-dimensional kinematic measurement of low back mobility.
Copyright © 1990. Published by Elsevier Ltd.

Entities:  

Year:  1990        PMID: 23916282     DOI: 10.1016/0268-0033(90)90005-Q

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  5 in total

1.  Three-dimensional relation of skin markers to lumbar vertebrae of healthy subjects in different postures measured by open MRI.

Authors:  Falk Mörl; Reinhard Blickhan
Journal:  Eur Spine J       Date:  2005-07-27       Impact factor: 3.134

2.  Individual characteristics of reliable lumbar coupling motions.

Authors:  Woo-Suck Yun; Hyunho Kim; Ji Hoon Ahn; Young-Bae Park; Young-Jae Park
Journal:  Eur Spine J       Date:  2015-06-24       Impact factor: 3.134

3.  Preliminary opto-electronic study on vertebral movement.

Authors:  G Vanneuville; T Kyndt; M Massaux; Y Harmand; J M Garcier; J P Monnet; M Guillot; P Cluzel; G Escande; G Poumarat
Journal:  Surg Radiol Anat       Date:  1994       Impact factor: 1.246

4.  Pose estimation with a Kinect for ergonomic studies: evaluation of the accuracy using a virtual mannequin.

Authors:  Pierre Plantard; Edouard Auvinet; Anne-Sophie Le Pierres; Franck Multon
Journal:  Sensors (Basel)       Date:  2015-01-15       Impact factor: 3.576

5.  Influence of Spine Curvature on the Efficacy of Transcutaneous Lumbar Spinal Cord Stimulation.

Authors:  Veronika E Binder; Ursula S Hofstoetter; Anna Rienmüller; Zoltán Száva; Matthias J Krenn; Karen Minassian; Simon M Danner
Journal:  J Clin Med       Date:  2021-11-26       Impact factor: 4.241

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.