Literature DB >> 23914859

A proof-of-concept in vitro study to determine if EndoAnchors can reduce gutter size in chimney graft configurations.

Wouter W Niepoth1, Jorg L de Bruin, Kak K Yeung, Rutger J Lely, Andrea N Devrome, Willem Wisselink, Jan D Blankensteijn.   

Abstract

PURPOSE: To investigate the feasibility of using endoanchor technology to reduce chimney graft-related gutter size in a juxtarenal aneurysm model.
METHODS: In silicone juxtarenal aortic aneurysm models with two sizes of branch arteries and two sizes of aorta, single chimney graft (CG) configurations were constructed using 6-mm Atrium balloon-expandable stent-grafts in association with two sizes of Gore Excluder main grafts (23 and 28.5 mm). Configurations without Aptus EndoAnchors, with suprarenal placement of EndoAnchors, and with additional infrarenal placement of EndoAnchors were investigated. A total of 12 CG configurations were scanned using 64-slice computed tomography. Gutter volume and gutter areas at the top and bottom of the sealing zone were measured with image processing software.
RESULTS: The combination of supra- and infrarenal placement of endoanchors led to a reduction in gutter volume compared to unanchored configurations. The same configurations also led to a decrease in gutter area at the bottom of the sealing zone.
CONCLUSION: It is feasible to reduce gutters in CG configurations with the use of endoanchors in an in vitro juxtarenal aneurysm model.

Entities:  

Mesh:

Year:  2013        PMID: 23914859     DOI: 10.1583/13-4228.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  6 in total

1.  Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.

Authors:  Edgar Luis Galiñanes; Eduardo A Hernandez-Vila; Zvonimir Krajcer
Journal:  Tex Heart Inst J       Date:  2015-02-01

2.  New Chimney after Chimney EVAR for the Treatment of Type Ia Endoleak.

Authors:  Spyridon N Mylonas; Konstantinos G Moulakakis; John D Kakisis; Elias N Brountzos; Christos D Liapis
Journal:  Int J Angiol       Date:  2015-07-10

3.  Deployment of stent graft in an excessively higher position above the renal artery induces a flow channel to the aneurysm in chimney endovascular aortic aneurysm repair: an in vitro study.

Authors:  Kota Shukuzawa; Taku Akaoka; Mitsuo Umezu; Takao Ohki; Kiyotaka Iwasaki
Journal:  J Artif Organs       Date:  2019-01-20       Impact factor: 1.731

4.  EndoAnchors Minimize Endoleaks in Chimney-Graft Endovascular Repair of Juxtarenal Abdominal Aortic Aneurysms.

Authors:  Edgar Luis Galiñanes; Eduardo A Hernandez-Vila; Zvonimir Krajcer
Journal:  Tex Heart Inst J       Date:  2019-06-01

5.  Secondary Fill Minimizes Gutter Size in Chimney EVAS Configurations In Vitro.

Authors:  Theodorus G van Schaik; Jorn P Meekel; Vincent Jongkind; Rutger J Lely; Maarten Truijers; Arjan W J Hoksbergen; Willem Wisselink; Jan D Blankensteijn; Kak Khee Yeung
Journal:  J Endovasc Ther       Date:  2018-12-21       Impact factor: 3.487

6.  Gutter Characteristics and Stent Compression of Self-Expanding vs Balloon-Expandable Chimney Grafts in Juxtarenal Aneurysm Models.

Authors:  Jorn P Meekel; Theodorus G van Schaik; Rutger J Lely; Gerie Groot; Bram B van der Meijs; Willem Wisselink; Jan D Blankensteijn; Kak K Yeung
Journal:  J Endovasc Ther       Date:  2020-04-21       Impact factor: 3.487

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.