Literature DB >> 30663032

Deployment of stent graft in an excessively higher position above the renal artery induces a flow channel to the aneurysm in chimney endovascular aortic aneurysm repair: an in vitro study.

Kota Shukuzawa1,2, Taku Akaoka3, Mitsuo Umezu1,3,4, Takao Ohki2, Kiyotaka Iwasaki5,6,7.   

Abstract

We aimed to investigate the influences of the sealing length above the renal artery (RA) on gutter formation, non-apposed regions between the aortic wall, stent graft (SG), and chimney graft and incidence of flow channel to the aneurysm in chimney endovascular aortic aneurysm repair (Ch-EVAR) using a juxtarenal abdominal aortic aneurysm model. Neck diameter and length of the silicone model were 24 and 4 mm, respectively. In double Ch-EVAR configuration using Advanta V12, 12 combinations were tested three times with two sizes [28.5 (20%-oversize) and 31 (30%-oversize) mm] of Excluder SG, three sealing lengths above the RA (10, 20, and 30 mm), and two deployment positions (anatomical and cross-leg). Gutter area, non-apposed region, and flow channels to the aneurysm were analyzed using micro-computed tomography. Average gutter area and non-apposed region of 30%-oversize SG were significantly smaller than those of 20%-oversize SG (p = 0.05). Furthermore, the non-apposed region of 30%-oversize SG with a 30-mm sealing length was significantly larger than that of the other sealing lengths. For 20%-oversize SGs, flow channel to the aneurysm was observed, except for the anatomical deployment with the sealing length of 10 mm. For 30%-oversize SGs, flow channel was absent, except for the SG with a 30-mm sealing length in both deployment positions. These flow channels were frequently formed through a valley space, existing in the lower unibody above the two limbs. Our data indicated that the optimal sealing length should be chosen in consideration of the device design difference due to the device diameter in Ch-EVAR.

Entities:  

Keywords:  Chimney technique; Endovascular aortic repair; Gutter; In vitro; Juxtarenal aortic aneurysm

Mesh:

Year:  2019        PMID: 30663032     DOI: 10.1007/s10047-019-01090-x

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  15 in total

1.  Diameter and compliance in the male human abdominal aorta: influence of age and aortic aneurysm.

Authors:  T Länne; B Sonesson; D Bergqvist; H Bengtsson; D Gustafsson
Journal:  Eur J Vasc Surg       Date:  1992-03

2.  Comparison of fenestrated endovascular aneurysm repair and chimney graft techniques for pararenal aortic aneurysm.

Authors:  Hiroshi Banno; Frédéric Cochennec; Jean Marzelle; Jean-Pierre Becquemin
Journal:  J Vasc Surg       Date:  2014-02-20       Impact factor: 4.268

3.  The best in vitro conditions for two and three parallel stenting during endovascular aneurysm repair.

Authors:  Gaspar Mestres; Xavier Yugueros; Ana Apodaka; Rodrigo Urrea; Savino Pasquadibisceglie; Xavier Alomar; Vincent Riambau
Journal:  J Vasc Surg       Date:  2017-06-26       Impact factor: 4.268

Review 4.  Chimney Grafts in Aortic Stent Grafting: Hazardous or Useful Technique? Systematic Review of Current Data.

Authors:  B Lindblad; A Bin Jabr; J Holst; M Malina
Journal:  Eur J Vasc Endovasc Surg       Date:  2015-09-11       Impact factor: 7.069

5.  The role of open and endovascular treatment with fenestrated and chimney endografts for patients with juxtarenal aortic aneurysms.

Authors:  Konstantinos P Donas; Markus Eisenack; Giuseppe Panuccio; Martin Austermann; Nani Osada; Giovanni Torsello
Journal:  J Vasc Surg       Date:  2012-05-02       Impact factor: 4.268

Review 6.  The chimney graft technique for preserving visceral vessels during endovascular treatment of aortic pathologies.

Authors:  Konstantinos G Moulakakis; Spyridon N Mylonas; Efthimios Avgerinos; Anastasios Papapetrou; John D Kakisis; Elias N Brountzos; Christos D Liapis
Journal:  J Vasc Surg       Date:  2012-01-10       Impact factor: 4.268

7.  Comparison between Open and Endovascular Repair for the Treatment of Juxtarenal Abdominal Aortic Aneurysms: A Single-Center Experience with Midterm Results.

Authors:  Koji Maeda; Takao Ohki; Yuji Kanaoka; Takeshi Baba; Kenjirou Kaneko; Kota Shukuzawa
Journal:  Ann Vasc Surg       Date:  2017-02-24       Impact factor: 1.466

8.  Geometric study of various chimney graft configurations in an in vitro juxtarenal aneurysm model.

Authors:  Jorg L de Bruin; Kak K Yeung; Wouter W Niepoth; Rutger J Lely; Qingfeng Cheung; Anesh de Vries; Jan D Blankensteijn
Journal:  J Endovasc Ther       Date:  2013-04       Impact factor: 3.487

9.  Should patients with challenging anatomy be offered endovascular aneurysm repair?

Authors:  Roy K Greenberg; Daniel Clair; Sunita Srivastava; Guru Bhandari; Adrian Turc; Jennifer Hampton; Matt Popa; Richard Green; Kenneth Ouriel
Journal:  J Vasc Surg       Date:  2003-11       Impact factor: 4.268

10.  Long-term follow-up of fenestrated endovascular repair for juxtarenal aortic aneurysm.

Authors:  I N Roy; A M Millen; S M Jones; S R Vallabhaneni; J R H Scurr; R G McWilliams; J A Brennan; R K Fisher
Journal:  Br J Surg       Date:  2017-04-12       Impact factor: 6.939

View more
  1 in total

Review 1.  Journal of Artificial Organs 2019: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; G Matsumiya; S Miyagawa; E Tatsumi; T Abe; K Fukunaga; S Ichiba; T Taguchi; K Kokubo; T Masuzawa; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; T Tsukiya; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2020-02-19       Impact factor: 1.731

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.