Literature DB >> 23912759

Three-dimensional anterior segment imaging in patients with type 1 Boston Keratoprosthesis with switchable full depth range swept source optical coherence tomography.

Raju Poddar1, Poddar Raju, Dennis E Cortés, John S Werner, Mark J Mannis, Robert J Zawadzki.   

Abstract

A high-speed (100 kHz A-scans/s) complex conjugate resolved 1 μm swept source optical coherence tomography (SS-OCT) system using coherence revival of the light source is suitable for dense three-dimensional (3-D) imaging of the anterior segment. The short acquisition time helps to minimize the influence of motion artifacts. The extended depth range of the SS-OCT system allows topographic analysis of clinically relevant images of the entire depth of the anterior segment of the eye. Patients with the type 1 Boston Keratoprosthesis (KPro) require evaluation of the full anterior segment depth. Current commercially available OCT systems are not suitable for this application due to limited acquisition speed, resolution, and axial imaging range. Moreover, most commonly used research grade and some clinical OCT systems implement a commercially available SS (Axsun) that offers only 3.7 mm imaging range (in air) in its standard configuration. We describe implementation of a common swept laser with built-in k-clock to allow phase stable imaging in both low range and high range, 3.7 and 11.5 mm in air, respectively, without the need to build an external MZI k-clock. As a result, 3-D morphology of the KPro position with respect to the surrounding tissue could be investigated in vivo both at high resolution and with large depth range to achieve noninvasive and precise evaluation of success of the surgical procedure.

Entities:  

Mesh:

Year:  2013        PMID: 23912759      PMCID: PMC3731227          DOI: 10.1117/1.JBO.18.8.086002

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  41 in total

1.  In vivo human retinal imaging by Fourier domain optical coherence tomography.

Authors:  Maciej Wojtkowski; Rainer Leitgeb; Andrzej Kowalczyk; Tomasz Bajraszewski; Adolf F Fercher
Journal:  J Biomed Opt       Date:  2002-07       Impact factor: 3.170

2.  Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second.

Authors:  Wolfgang Wieser; Benjamin R Biedermann; Thomas Klein; Christoph M Eigenwillig; Robert Huber
Journal:  Opt Express       Date:  2010-07-05       Impact factor: 3.894

3.  Evaluation of the stability of Boston type I keratoprosthesis-donor cornea interface using anterior segment optical coherence tomography.

Authors:  Julian P S Garcia; David C Ritterband; Douglas F Buxton; Jose De la Cruz
Journal:  Cornea       Date:  2010-09       Impact factor: 2.651

4.  Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source.

Authors:  Michael A Choma; Kevin Hsu; Joseph A Izatt
Journal:  J Biomed Opt       Date:  2005 Jul-Aug       Impact factor: 3.170

5.  Buffered Fourier domain mode locking: Unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s.

Authors:  Robert Huber; Desmond C Adler; James G Fujimoto
Journal:  Opt Lett       Date:  2006-10-15       Impact factor: 3.776

6.  Three-dimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments.

Authors:  Yoshiaki Yasuno; Violeta Dimitrova Madjarova; Shuichi Makita; Masahiro Akiba; Atsushi Morosawa; Changho Chong; Toru Sakai; Kin-Pui Chan; Masahide Itoh; Toyohiko Yatagai
Journal:  Opt Express       Date:  2005-12-26       Impact factor: 3.894

7.  Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principles.

Authors:  R Huber; M Wojtkowski; K Taira; J Fujimoto; K Hsu
Journal:  Opt Express       Date:  2005-05-02       Impact factor: 3.894

8.  Imaging the ocular anterior segment with real-time, full-range Fourier-domain optical coherence tomography.

Authors:  Marinko V Sarunic; Sanjay Asrani; Joseph A Izatt
Journal:  Arch Ophthalmol       Date:  2008-04

9.  Megahertz OCT for ultrawide-field retinal imaging with a 1050 nm Fourier domain mode-locked laser.

Authors:  Thomas Klein; Wolfgang Wieser; Christoph M Eigenwillig; Benjamin R Biedermann; Robert Huber
Journal:  Opt Express       Date:  2011-02-14       Impact factor: 3.894

10.  Boston type I keratoprosthesis-donor cornea interface evaluated by high-definition spectral-domain anterior segment optical coherence tomography.

Authors:  Ana G Alzaga Fernandez; Nathan M Radcliffe; Kimberly C Sippel; Mark I Rosenblatt; Priyanka Sood; Christopher E Starr; Jessica B Ciralsky; Donald J D'Amico; Szilárd Kiss
Journal:  Clin Ophthalmol       Date:  2012-08-27
View more
  5 in total

1.  In vivo imaging of human vasculature in the chorioretinal complex using phase-variance contrast method with phase-stabilized 1-μm swept-source optical coherence tomography.

Authors:  Raju Poddar; Dae Yu Kim; John S Werner; Robert J Zawadzki
Journal:  J Biomed Opt       Date:  2014-12       Impact factor: 3.170

2.  Spectrally encoded coherence tomography and reflectometry: Simultaneous en face and cross-sectional imaging at 2 gigapixels per second.

Authors:  Mohamed T El-Haddad; Ivan Bozic; Yuankai K Tao
Journal:  J Biophotonics       Date:  2017-12-27       Impact factor: 3.207

3.  Comparison of amplitude-decorrelation, speckle-variance and phase-variance OCT angiography methods for imaging the human retina and choroid.

Authors:  Iwona Gorczynska; Justin V Migacz; Robert J Zawadzki; Arlie G Capps; John S Werner
Journal:  Biomed Opt Express       Date:  2016-02-19       Impact factor: 3.732

4.  In vivo volumetric depth-resolved vasculature imaging of human limbus and sclera with 1μm swept source phase-variance optical coherence angiography.

Authors:  Raju Poddar; Robert J Zawadzki; Dennis E Cortés; Mark J Mannis; John S Werner
Journal:  J Opt       Date:  2015-06       Impact factor: 2.516

5.  Conical scan pattern for enhanced visualization of the human cornea using polarization-sensitive OCT.

Authors:  Florian Beer; Andreas Wartak; Richard Haindl; Martin Gröschl; Bernhard Baumann; Michael Pircher; Christoph K Hitzenberger
Journal:  Biomed Opt Express       Date:  2017-05-08       Impact factor: 3.732

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.