Literature DB >> 23911179

Penny wise and pound foolish: will shortsighted cost reduction measures compromise patient access to promising self-monitoring of blood glucose technology?

Christopher G Parkin1.   

Abstract

In this issue of Journal of Diabetes Science and Technology, Grady and coauthors enrolled 101 patients with type 1 and type 2 diabetes to evaluate new technology incorporated into the LifeScan VerioPro and VerioIQ blood glucose meters. The "pattern detection" software provides real-time, onscreen messages that alert users to patterns of high glucose (fasting and premeal) and low glucose as they are detected. The study showed that most participants possess a good understanding of the factors that can cause hyperglycemia; however, their understanding of the causes of hypoglycemia events was not as strong. Nevertheless, more than 70% of participants indicated they preferred to use a blood glucose meter that provides pattern detection capability. Although not designed to assess the impact of the pattern detection tool on clinical outcomes, the study highlights the value of continuous innovation in self-monitoring of blood glucose (SMBG) technology among manufacturers. Unfortunately, many patients may never have access to these systems due to reductions in Medicare reimbursement. Instead, they may be forced to use SMBG systems that are inaccurate and provide inadequate patient support. Stronger regulatory requirements are needed to ensure that all SMBG systems marketed to patients are accurate, reliable, and supported by adequate patient training, and current health care reimbursement policies should be restructured to encourage manufacturers to continue their efforts to develop innovative technology to further improve the utility and usability of their SMBG systems.
© 2013 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23911179      PMCID: PMC3879762          DOI: 10.1177/193229681300700420

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  24 in total

1.  Risky delay of hypoglycemia detection by glucose monitoring at the arm.

Authors:  K Jungheim; T Koschinsky
Journal:  Diabetes Care       Date:  2001-07       Impact factor: 19.112

2.  Implementation of capillary blood glucose monitoring in a teaching hospital and determination of program requirements to maintain quality testing.

Authors:  K Lewandrowski; R Cheek; D M Nathan; J E Godine; K Hurxthal; K Eschenbach; M Laposata
Journal:  Am J Med       Date:  1992-10       Impact factor: 4.965

3.  Self-monitoring of blood glucose with finger tip versus alternative site sampling: effect on glycemic control in insulin-using patients with type 2 diabetes.

Authors:  Philip E Knapp; Kara M Showers; Jenna C Phipps; Jeanne L Speckman; Elliot Sternthal; Karen M Freund; Arlene S Ash; Caroline M Apovian
Journal:  Diabetes Technol Ther       Date:  2009-04       Impact factor: 6.118

4.  Rapid changes in postprandial blood glucose produce concentration differences at finger, forearm, and thigh sampling sites.

Authors:  John M Ellison; Janet M Stegmann; Sandra L Colner; Ragui H Michael; Manoj K Sharma; Kenneth R Ervin; David L Horwitz
Journal:  Diabetes Care       Date:  2002-06       Impact factor: 19.112

5.  Glucose monitoring at the arm: risky delays of hypoglycemia and hyperglycemia detection.

Authors:  Karsten Jungheim; Theodor Koschinsky
Journal:  Diabetes Care       Date:  2002-06       Impact factor: 19.112

6.  System accuracy evaluation of 27 blood glucose monitoring systems according to DIN EN ISO 15197.

Authors:  Guido Freckmann; Annette Baumstark; Nina Jendrike; Eva Zschornack; Serge Kocher; Jacques Tshiananga; Frank Heister; Cornelia Haug
Journal:  Diabetes Technol Ther       Date:  2010-03       Impact factor: 6.118

7.  Evaluation of a simple policy for pre- and post-prandial blood glucose self-monitoring in people with type 2 diabetes not on insulin.

Authors:  Katia Bonomo; Alessandro De Salve; Elisa Fiora; Elena Mularoni; Paola Massucco; Paolo Poy; Alice Pomero; Franco Cavalot; Giovanni Anfossi; Mariella Trovati
Journal:  Diabetes Res Clin Pract       Date:  2009-12-01       Impact factor: 5.602

8.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus.

Authors:  D M Nathan; S Genuth; J Lachin; P Cleary; O Crofford; M Davis; L Rand; C Siebert
Journal:  N Engl J Med       Date:  1993-09-30       Impact factor: 91.245

Review 9.  Diabetes in the elderly.

Authors:  G S Meneilly; D Tessier
Journal:  Diabet Med       Date:  1995-11       Impact factor: 4.359

10.  Counterregulatory hormone responses to hypoglycemia in the elderly patient with diabetes.

Authors:  G S Meneilly; E Cheung; H Tuokko
Journal:  Diabetes       Date:  1994-03       Impact factor: 9.461

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.