Literature DB >> 23906549

Gradient echo based fiber orientation mapping using R2* and frequency difference measurements.

Samuel Wharton1, Richard Bowtell.   

Abstract

Fiber orientation mapping through diffusion tensor imaging (DTI) is a powerful MRI-based technique for visualising white matter (WM) microstructure in the brain. Although DTI provides a robust way to measure fiber orientation, it has some limitations linked to the use of EPI read-outs and long diffusion encoding periods, including relatively low spatial resolution. Development of alternative MRI-based methods for fiber orientation mapping is therefore valuable, in part to allow validation of DTI results. In this study, we used the orientation dependence of R2* (1/T2*) and frequency difference measurements to generate three dimensional maps of the fiber orientation in WM from multi-echo gradient-echo (GE) images acquired from post mortem brain tissue samples oriented at multiple angles to B0. Through analytical derivation and numerical simulation, the relationships connecting variations in R2* and frequency difference values to the angle between the underlying WM fiber orientation and the direction of B0 were characterised. High resolution 3D fiber orientation maps (FOM) were then formed by comparing R2* and frequency difference data, acquired with the sample at multiple orientations to the field, to generalised models based on the derived expressions for the angular dependence of each parameter. By comparing the resulting GE-based FOM with DTI-based FOM from the same tissue sample, we demonstrate that fiber orientation mapping based on gradient echo MRI has the potential to become an important tool for investigating microstructure in brain tissue.
© 2013.

Keywords:  Fiber direction; Gradient-echo MRI; Magnetic susceptibility; Microstructure; Myelin-water; Phase contrast

Mesh:

Year:  2013        PMID: 23906549     DOI: 10.1016/j.neuroimage.2013.07.054

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  25 in total

1.  Characterizing white matter fiber orientation effects on multi-parametric quantitative BOLD assessment of oxygen extraction fraction.

Authors:  Stephan Kaczmarz; Jens Göttler; Claus Zimmer; Fahmeed Hyder; Christine Preibisch
Journal:  J Cereb Blood Flow Metab       Date:  2019-04-05       Impact factor: 6.200

Review 2.  Studying brain microstructure with magnetic susceptibility contrast at high-field.

Authors:  Jeff H Duyn
Journal:  Neuroimage       Date:  2017-02-24       Impact factor: 6.556

Review 3.  Contributions to magnetic susceptibility of brain tissue.

Authors:  Jeff H Duyn; John Schenck
Journal:  NMR Biomed       Date:  2016-05-30       Impact factor: 4.044

4.  Phase imaging in brain using SWIFT.

Authors:  Lauri Juhani Lehto; Michael Garwood; Olli Gröhn; Curtis Andrew Corum
Journal:  J Magn Reson       Date:  2015-01-03       Impact factor: 2.229

5.  B0 -orientation dependent magnetic susceptibility-induced white matter contrast in the human brainstem at 11.7T.

Authors:  Manisha Aggarwal; Yusuke Kageyama; Xu Li; Peter C van Zijl
Journal:  Magn Reson Med       Date:  2016-03-28       Impact factor: 4.668

6.  The influence of molecular order and microstructure on the R2* and the magnetic susceptibility tensor.

Authors:  Cynthia Wisnieff; Tian Liu; Yi Wang; Pascal Spincemaille
Journal:  Magn Reson Imaging       Date:  2015-12-10       Impact factor: 2.546

7.  Exploring the origins of echo-time-dependent quantitative susceptibility mapping (QSM) measurements in healthy tissue and cerebral microbleeds.

Authors:  Matthew J Cronin; Nian Wang; Kyle S Decker; Hongjiang Wei; Wen-Zhen Zhu; Chunlei Liu
Journal:  Neuroimage       Date:  2017-01-23       Impact factor: 6.556

8.  The effects of variations in tissue microstructure from postmortem rat brain on the asymmetry of the water proton resonance.

Authors:  Sean Foxley; Gregory S Karczmar; Kazutaka Takahashi
Journal:  Magn Reson Med       Date:  2018-07-16       Impact factor: 4.668

9.  Mean magnetic susceptibility regularized susceptibility tensor imaging (MMSR-STI) for estimating orientations of white matter fibers in human brain.

Authors:  Xu Li; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2014-06-27       Impact factor: 4.668

10.  Joint eigenvector estimation from mutually anisotropic tensors improves susceptibility tensor imaging of the brain, kidney, and heart.

Authors:  Russell Dibb; Chunlei Liu
Journal:  Magn Reson Med       Date:  2016-07-06       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.