Literature DB >> 23900941

Intraindividual evaluation of the influence of iterative reconstruction and filter kernel on subjective and objective image quality in computed tomography of the brain.

J H Buhk1, A Laqmani, H C von Schultzendorff, D Hammerle, S Sehner, G Adam, J Fiehler, H D Nagel, M Regier.   

Abstract

OBJECTIVES: To intraindividually evaluate the potential of 4th generation iterative reconstruction (IR) on brain CT with regard to subjective and objective image quality.
METHODS: 31 consecutive raw data sets of clinical routine native sequential brain CT scans were reconstructed with IR level 0 (= filtered back projection), 1, 3 and 4; 3 different brain filter kernels (smooth/standard/sharp) were applied respectively. Five independent radiologists with different levels of experience performed subjective image rating. Detailed ROI analysis of image contrast and noise was performed. Statistical analysis was carried out by applying a random intercept model.
RESULTS: Subjective scores for the smooth and the standard kernels were best at low IR levels, but both, in particular the smooth kernel, scored inferior with an increasing IR level. The sharp kernel scored lowest at IR 0, while the scores substantially increased at high IR levels, reaching significantly best scores at IR 4. Objective measurements revealed an overall increase in contrast-to-noise ratio at higher IR levels, which was highest when applying the soft filter kernel. The absolute grey-white contrast decreased with an increasing IR level and was highest when applying the sharp filter kernel. All subjective effects were independent of the raters' experience and the patients' age and sex.
CONCLUSION: Different combinations of IR level and filter kernel substantially influence subjective and objective image quality of brain CT. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2013        PMID: 23900941     DOI: 10.1055/s-0033-1335937

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  5 in total

1.  Dose reduction in standard head CT: first results from a new scanner using iterative reconstruction and a new detector type in comparison with two previous generations of multi-slice CT.

Authors:  C Ozdoba; J Slotboom; G Schroth; S Ulzheimer; R Kottke; H Watzal; C Weisstanner
Journal:  Clin Neuroradiol       Date:  2014-01-31       Impact factor: 3.649

2.  Image Quality of 3rd Generation Spiral Cranial Dual-Source CT in Combination with an Advanced Model Iterative Reconstruction Technique: A Prospective Intra-Individual Comparison Study to Standard Sequential Cranial CT Using Identical Radiation Dose.

Authors:  Holger Wenz; Máté E Maros; Mathias Meyer; Alex Förster; Holger Haubenreisser; Stefan Kurth; Stefan O Schoenberg; Thomas Flohr; Christianne Leidecker; Christoph Groden; Johann Scharf; Thomas Henzler
Journal:  PLoS One       Date:  2015-08-19       Impact factor: 3.240

Review 3.  Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT.

Authors:  Holger Wenz; Máté E Maros; Mathias Meyer; Joshua Gawlitza; Alex Förster; Holger Haubenreisser; Stefan Kurth; Stefan O Schoenberg; Christoph Groden; Thomas Henzler
Journal:  Eur J Radiol Open       Date:  2016-07-26

4.  Iterative Reconstruction Improves Both Objective and Subjective Image Quality in Acute Stroke CTP.

Authors:  Fabian Flottmann; Jan Kabath; Till Illies; Tanja Schneider; Jan-Hendrik Buhk; Jens Fiehler; André Kemmling
Journal:  PLoS One       Date:  2016-03-01       Impact factor: 3.240

5.  CT Pulmonary Angiography at Reduced Radiation Exposure and Contrast Material Volume Using Iterative Model Reconstruction and iDose4 Technique in Comparison to FBP.

Authors:  Azien Laqmani; Maximillian Kurfürst; Sebastian Butscheidt; Susanne Sehner; Jakob Schmidt-Holtz; Cyrus Behzadi; Hans Dieter Nagel; Gerhard Adam; Marc Regier
Journal:  PLoS One       Date:  2016-09-09       Impact factor: 3.240

  5 in total