Literature DB >> 23900630

Rigid variety occiput/C1-C2-C3 internal fixation in pediatric population.

Sanjiv Sinha1, Anita Jagetia, Aher Rajendra Bhausaheb, Manojkumar V Butte, Rahul Jain.   

Abstract

PURPOSE: The purpose of this study was to review our experience of rigid internal fixation of craniovertebral junction in pediatric population. A new technique of reduction of basilar invagination with atlantoaxial dislocation is described. To the best of our knowledge and available scientific literature, this technique has not yet been described in younger patients.
METHODS: We have managed 27 children by rigid variety of occiput/C1-C2-C3 internal fixation of various craniovertebral junction pathologies. All patients were subjected to thin cuts of computed tomography with 3D reconstruction for selecting appropriate rigid construct. Eight children had occiput-C2, 3 had occiput-C2-C3, and 16 had C1-C2 hardware constuct. One patient of C1-C2-plate fixation had section of C2 nerve root ganglia. Basilar invagination with atlantoaxial dislocation was reduced by new distraction/compression techniques.
RESULTS: Improvement in clinical features and correction of deformity with solid hardware construct were seen in all patients. Follow-up period ranged from 5-72 months. One patient was lost to follow-up, and one case died of compression of vertebral artery at C1 lateral mass. Patients of myelopathy had recovery rate of 90.9%. Hardware failure was seen in one patient, and wound infection was observed in two cases.
CONCLUSIONS: Rigid variety of occiput/C1-C2 internal fixation is a safe and effective method in the management of variety of craniovertebral pathologies in pediatric population. This new technique of reduction of basilar invagination with atlantoaxilal dislocation from posterior approach may alleviate the need of high morbity associated with surgical procedure like transoral odontoidectomy in younger patients.

Entities:  

Mesh:

Year:  2013        PMID: 23900630     DOI: 10.1007/s00381-013-2232-3

Source DB:  PubMed          Journal:  Childs Nerv Syst        ISSN: 0256-7040            Impact factor:   1.475


  33 in total

1.  Anatomic considerations for the placement of C2 laminar screws.

Authors:  Ezequiel H Cassinelli; Michael Lee; Anthony Skalak; Nicholas U Ahn; Neill M Wright
Journal:  Spine (Phila Pa 1976)       Date:  2006-11-15       Impact factor: 3.468

2.  Incorporation of C-1 lateral mass screws in occipitocervical and atlantoaxial fusions for children 8 years of age or younger. Technical note.

Authors:  Andrew Jea; Michael D Taylor; Peter B Dirks; Abhaya V Kulkarni; James T Rutka; James M Drake
Journal:  J Neurosurg       Date:  2007-08       Impact factor: 5.115

3.  Anatomical suitability of C1-2 transarticular screw placement in pediatric patients.

Authors:  D L Brockmeyer; J E York; R I Apfelbaum
Journal:  J Neurosurg       Date:  2000-01       Impact factor: 5.115

4.  Occipitocervical arthrodesis in children.

Authors:  M Letts; D Slutsky
Journal:  J Bone Joint Surg Am       Date:  1990-09       Impact factor: 5.284

5.  Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 67 pediatric patients.

Authors:  Wayne M Gluf; Douglas L Brockmeyer
Journal:  J Neurosurg Spine       Date:  2005-02

6.  Surgical management and outcome of tuberculous atlantoaxial dislocation: a 15-year experience.

Authors:  Sanjiv Sinha; Anil Kumar Singh; Vikas Gupta; Daljit Singh; Masakazu Takayasu; Jun Yoshida
Journal:  Neurosurgery       Date:  2003-02       Impact factor: 4.654

7.  C1-C2 posterior cervical fusion: long-term evaluation of results and efficacy.

Authors:  T J Coyne; M G Fehlings; M C Wallace; M Bernstein; C H Tator
Journal:  Neurosurgery       Date:  1995-10       Impact factor: 4.654

8.  Use of axial and subaxial translaminar screw fixation in the management of upper cervical spinal instability in a series of 7 children.

Authors:  Roukoz B Chamoun; Katherine M Relyea; Keyne K Johnson; William E Whitehead; Daniel J Curry; Thomas G Luerssen; James M Drake; Andrew Jea
Journal:  Neurosurgery       Date:  2009-04       Impact factor: 4.654

9.  Selection of a rigid internal fixation construct for stabilization at the craniovertebral junction in pediatric patients.

Authors:  Richard C E Anderson; Brian T Ragel; J Mocco; Leif-Erik Bohman; Douglas L Brockmeyer
Journal:  J Neurosurg       Date:  2007-07       Impact factor: 5.115

10.  Pediatric cervical spine instrumentation using screw fixation.

Authors:  D Brockmeyer; R Apfelbaum; R Tippets; M Walker; L Carey
Journal:  Pediatr Neurosurg       Date:  1995       Impact factor: 1.162

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.