Dual-energy CT based vascular iodine analysis improves sensitivity for peripheral pulmonary artery thrombus detection: an experimental study in canines.

Chun Xiang Tang1, Long Jiang Zhang, Zong Hong Han, Chang Sheng Zhou, Aleksander W Krazinski, Justin R Silverman, U Joseph Schoepf, Guang Ming Lu.   

Abstract

PURPOSE: To evaluate the performance of dual-energy CT (DECT) based vascular iodine analysis for the detection of acute peripheral pulmonary thrombus (PE) in a canine model with histopathological findings as the reference standard.
MATERIALS AND METHODS: The study protocol was approved by our institutional animal committee. Thrombi (n = 12) or saline (n = 4) were intravenously injected via right femoral vein in sixteen dogs, respectively. CT pulmonary angiography (CTPA) in DECT mode was performed and conventional CTPA images and DECT based vascular iodine studies using Lung Vessels application were reconstructed. Two radiologists visually evaluated the number and location of PEs using conventional CTPA and DECT series on a per-animal and a per-clot basis. Detailed histopathological examination of lung specimens and catheter angiography served as reference standard. Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of DECT and CTPA were calculated on a segmental and subsegmental or more distal pulmonary artery basis. Weighted κ values were computed to evaluate inter-modality and inter-reader agreement.
RESULTS: Thirteen dogs were enrolled for final image analysis (experimental group = 9, control group = 4). Histopathological results revealed 237 emboli in 45 lung lobes in 9 experimental dogs, 11 emboli in segmental pulmonary arteries, 49 in subsegmental pulmonary arteries, 177 in fifth-order or more distal pulmonary arteries. Overall sensitivity, specificity, accuracy, PPV, and NPV for CTPA plus DECT were 93.1%, 76.9%, 87.8%, 89.4%, and 84.2% for the detection of pulmonary emboli. With CTPA versus DECT, sensitivities, specificities, accuracies, PPVs, and NPVs are all 100% for the detection of pulmonary emboli on a segmental pulmonary artery basis, 88.9%, 100%, 96.0%, 100%, and 94.1% for CTPA and 90.4%, 93.0%, 92.0%, 88.7%, and 94.1% for DECT on a subsegmental pulmonary artery basis; 23.8%, 96.4%, 50.4%, 93.5%, and 36.7% for CTPA and 95.9%, 75.5%, 88.2%, 86.5%, and 91.9% on a sub-subsegmental and more distal pulmonary artery basis, respectively. Good inter-modality (κ = 0.65, P<0.001) and inter-reader (κ = 0.70, P<0.001) agreement were observed.
CONCLUSION: With histopathological findings as the reference standard, DECT based vascular iodine analysis improves the sensitivity for detecting peripheral PE compared with CTPA, albeit at the price of decreased specificity and PPV.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Accuracy; Dual energy; Experimental model; Inter-rater reliability; Iodine-selective imaging; Pulmonary embolism

Mesh:

Substances:

Year:  2013        PMID: 23891532     DOI: 10.1016/j.ejrad.2013.06.021

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  12 in total

Review 1.  Imaging techniques for tumour delineation and heterogeneity quantification of lung cancer: overview of current possibilities.

Authors:  Wouter van Elmpt; Catharina M L Zegers; Marco Das; Dirk De Ruysscher
Journal:  J Thorac Dis       Date:  2014-04       Impact factor: 2.895

Review 2.  Multidetector computed tomography pulmonary angiography in childhood acute pulmonary embolism.

Authors:  Chun Xiang Tang; U Joseph Schoepf; Shahryar M Chowdhury; Mary A Fox; Long Jiang Zhang; Guang Ming Lu
Journal:  Pediatr Radiol       Date:  2015-04-07

Review 3.  State of the art: utility of multi-energy CT in the evaluation of pulmonary vasculature.

Authors:  Prabhakar Rajiah; Yuki Tanabe; Sasan Partovi; Alastair Moore
Journal:  Int J Cardiovasc Imaging       Date:  2019-05-02       Impact factor: 2.357

4.  Pulmonary Embolism Detection with Three-dimensional Ultrashort Echo Time MR Imaging: Experimental Study in Canines.

Authors:  Peter Bannas; Laura C Bell; Kevin M Johnson; Mark L Schiebler; Christopher J François; Utaroh Motosugi; Daniel Consigny; Scott B Reeder; Scott K Nagle
Journal:  Radiology       Date:  2015-09-30       Impact factor: 11.105

Review 5.  Computed tomography of acute pulmonary embolism: state-of-the-art.

Authors:  Long Jiang Zhang; Guang Ming Lu; Felix G Meinel; Andrew D McQuiston; James G Ravenel; U Joseph Schoepf
Journal:  Eur Radiol       Date:  2015-03-13       Impact factor: 5.315

6.  Dual-Energy CT Angiography for Detection of Pulmonary Emboli: Incremental Benefit of Iodine Maps.

Authors:  Elizabeth K Weidman; Andrew J Plodkowski; Darragh F Halpenny; Sara A Hayes; Rocio Perez-Johnston; Junting Zheng; Chaya Moskowitz; Michelle S Ginsberg
Journal:  Radiology       Date:  2018-09-11       Impact factor: 11.105

7.  Determination of iodine detectability in different types of multiple-energy images for a photon-counting detector computed tomography system.

Authors:  Wei Zhou; Gregory Michalak; Jayse Weaver; Andrea Ferrero; Hao Gong; Kenneth A Fetterly; Cynthia H McCollough; Shuai Leng
Journal:  J Med Imaging (Bellingham)       Date:  2019-10-15

8.  Diagnostic Value of Dual-Source Computerized Tomography Combined with Perfusion Imaging for Peripheral Pulmonary Embolism.

Authors:  Xijin Mao; Shanshan Wang; Xingyue Jiang; Lin Zhang; Wenjian Xu
Journal:  Iran J Radiol       Date:  2016-03-14       Impact factor: 0.212

9.  Diagnostic yield of CT thorax angiography in patients suspected of pulmonary embolism: independent predictors and protocol adherence.

Authors:  Stefan Walen; Minke-Alie Leijstra; Steven M Uil; Martijn F Boomsma; Jan Willem K van den Berg
Journal:  Insights Imaging       Date:  2014-04-03

Review 10.  Advances in Multidetector CT Diagnosis of Pediatric Pulmonary Thromboembolism.

Authors:  Paul G Thacker; Edward Y Lee
Journal:  Korean J Radiol       Date:  2016-03-02       Impact factor: 3.500

View more