Literature DB >> 23891300

Effect of microfiltration concentration factor on serum protein removal from skim milk using spiral-wound polymeric membranes.

S L Beckman1, D M Barbano.   

Abstract

Our objective was to determine the effect of concentration factor (CF) on the removal of serum protein (SP) from skim milk during microfiltration (MF) at 50 °C using a 0.3-μm-pore-size spiral-wound (SW) polymeric polyvinylidene fluoride (PVDF) membrane. Pasteurized (72°C for 16 s) skim milk was MF (50 °C) at 3 CF (1.50, 2.25, and 3.00×), each on a separate day of processing starting with skim milk. Two phases of MF were used at each CF, with an initial startup-stabilization phase (40 min in full recycle mode) to achieve the desired CF, followed by a steady-state phase (90-min feed-and-bleed with recycle) where data was collected. The experiment was replicated 3 times, and SP removal from skim milk was quantified at each CF. System pressures, flow rates, CF, and fluxes were monitored during the 90-min run. Permeate flux increased (12.8, 15.3, and 19.0 kg/m(2) per hour) with decreasing CF from 3.00 to 1.50×, whereas fouled water flux did not differ among CF, indicating that the effect of membrane fouling on hydraulic resistance of the membrane was similar at all CF. However, the CF used when microfiltering skim milk (50°C) with a 0.3-μm polymeric SW PVDF membrane did affect the percentage of SP removed. As CF increased from 1.50 to 3.00×, the percentage of SP removed from skim milk increased from 10.56 to 35.57%, in a single stage bleed-and-feed MF system. Percentage SP removal from skim milk was lower than the theoretical value. Rejection of SP during MF of skim milk with SW PVDF membranes was caused by fouling of the membrane, not by the membrane itself and differences in the foulant characteristic among CF influenced SP rejection more than it influenced hydraulic resistance. We hypothesize that differences in the conditions near the surface of the membrane and within the pores during the first few minutes of processing, when casein micelles pass through the membrane, influenced the rejection of SP because more pore size narrowing and plugging occurred at low CF than at high CF due to a slower rate of gel layer formation at low CF. It is possible that percentage removal of SP from skim milk at 50 °C could be improved by optimization of the membrane pore size, feed solution composition and concentration, and controlling the rate of formation of the concentration polarization-derived gel layer at the surface of the membrane during the first few minutes of processing.
Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  concentration factor; microfiltration; serum protein; spiral-wound membrane

Mesh:

Substances:

Year:  2013        PMID: 23891300     DOI: 10.3168/jds.2013-6655

Source DB:  PubMed          Journal:  J Dairy Sci        ISSN: 0022-0302            Impact factor:   4.034


  3 in total

1.  On the Use of Ultrafiltration or Microfiltration Polymeric Spiral-Wound Membranes for Cheesemilk Standardization: Impact on Process Efficiency.

Authors:  Julien Chamberland; Dany Mercier-Bouchard; Iris Dussault-Chouinard; Scott Benoit; Alain Doyen; Michel Britten; Yves Pouliot
Journal:  Foods       Date:  2019-06-08

2.  Influence of Spacer Design and Module Geometry on the Filtration Performance during Skim Milk Microfiltration with Flat Sheet and Spiral-Wound Membranes.

Authors:  Martin Hartinger; Jonas Napiwotzki; Eva-Maria Schmid; Dominik Hoffmann; Franziska Kurz; Ulrich Kulozik
Journal:  Membranes (Basel)       Date:  2020-03-26

3.  Comparative Assessment of Tubular Ceramic, Spiral Wound, and Hollow Fiber Membrane Microfiltration Module Systems for Milk Protein Fractionation.

Authors:  Roland Schopf; Florian Schmidt; Johanna Linner; Ulrich Kulozik
Journal:  Foods       Date:  2021-03-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.