Literature DB >> 23888425

Prolonged heterogeneous liver enhancement on contrast-enhanced ultrasound.

X W Cui1, A Ignee1, M Hocke2, K Seitz3, G Schrade4, C F Dietrich1.   

Abstract

INTRODUCTION: Prolonged heterogeneous liver enhancement (PHLE) is a rare phenomenon that is similar to the ultrasound findings of portal venous gas. The purpose of this report is to describe the phenomenon of PHLE after the injection of the ultrasound contrast agent SonoVue(®). PATIENTS AND METHODS: From 2000 to 2013, 13 patients with PHLE ("cloudy", "wool-like") after bolus injection of SonoVue(®) were observed. The height, weight, and body mass index (BMI) of the patients, and the number of injections were analyzed. In addition, the literature was reviewed.
RESULTS: The phenomenon occurred as early as 2 minutes after bolus contrast administration and lasted up to 5 hours on both B-mode and contrast-specific ultrasound. 8/13 (62 %) patients received two or more boluses. None of the patients experienced SonoVue(®)-related side effects or health problems. The phenomenon was not reproducible in 3 patients who received a second SonoVue(®) injection 24 hours after receiving the first.
CONCLUSION: This phenomenon is more likely to occur in patients who receive high-dose (or multiple) injections of UCA. It may occur as early as 2 minutes after contrast administration, and therefore, may affect the evaluation of focal liver lesions in the late phase. This phenomenon should not be misdiagnosed as a pathological finding of the liver. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23888425     DOI: 10.1055/s-0033-1350202

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  3 in total

Review 1.  [Postmortem sonography helpful in death of unknown origin].

Authors:  T Thomsen; C F Dietrich
Journal:  Med Klin Intensivmed Notfmed       Date:  2021-02-09       Impact factor: 0.840

Review 2.  Dynamic contrast-enhanced endoscopic ultrasound: A quantification method.

Authors:  Christoph F Dietrich; Yi Dong; Eckhart Froehlich; Michael Hocke
Journal:  Endosc Ultrasound       Date:  2017 Jan-Feb       Impact factor: 5.628

Review 3.  How to perform Contrast-Enhanced Ultrasound (CEUS).

Authors:  Christoph F Dietrich; Michalakis Averkiou; Michael Bachmann Nielsen; Richard G Barr; Peter N Burns; Fabrizio Calliada; Vito Cantisani; Byung Choi; Maria C Chammas; Dirk-André Clevert; Michel Claudon; Jean-Michel Correas; Xin-Wu Cui; David Cosgrove; Mirko D'Onofrio; Yi Dong; JohnR Eisenbrey; Teresa Fontanilla; Odd Helge Gilja; Andre Ignee; Christian Jenssen; Yuko Kono; Masatoshi Kudo; Nathalie Lassau; Andrej Lyshchik; Maria Franca Meloni; Fuminori Moriyasu; Christian Nolsøe; Fabio Piscaglia; Maija Radzina; Adrian Saftoiu; Paul S Sidhu; Ioan Sporea; Dagmar Schreiber-Dietrich; Claude B Sirlin; Maria Stanczak; Hans-Peter Weskott; Stephanie R Wilson; Juergen Karl Willmann; Tae Kyoung Kim; Hyun-Jung Jang; Alexandar Vezeridis; Sue Westerway
Journal:  Ultrasound Int Open       Date:  2018-02-07
  3 in total