Literature DB >> 2388748

The multi-purpose camera: a new anterior eye segment analysis system.

K Sasaki1, Y Sakamoto, T Shibata, Y Emori.   

Abstract

A new device for the analysis of the anterior eye segment was developed. With this device, a Scheimpflug slit image and a retroillumination image can be taken separately using a CCD camera. The quality of the images obtained was satisfactory enough for analysis. The data obtained were stored and analyzed on an almost real-time level using an on-line computer. The menu for the data analysis provided for this device includes multilinear densitometry, with planimetry, area densitometry, measurement of anterior chamber depth and thickness of lens layers, determination of chamber angle and positioning of implanted intraocular lenses, and measurement of opaque areas in the retroillumination image.

Entities:  

Mesh:

Year:  1990        PMID: 2388748     DOI: 10.1159/000267056

Source DB:  PubMed          Journal:  Ophthalmic Res        ISSN: 0030-3747            Impact factor:   2.892


  6 in total

1.  A newly developed peripheral anterior chamber depth analysis system: principle, accuracy, and reproducibility.

Authors:  K Kashiwagi; F Kashiwagi; Y Toda; K Osada; T Tsumura; S Tsukahara
Journal:  Br J Ophthalmol       Date:  2004-08       Impact factor: 4.638

2.  Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration.

Authors:  T Oshika; G Sugita; K Miyata; T Tokunaga; T Samejima; C Okamoto; Y Ishii
Journal:  Br J Ophthalmol       Date:  2006-08-16       Impact factor: 4.638

3.  Anterior capsular contraction after cataract surgery in eyes of diabetic patients.

Authors:  S Kato; T Oshika; J Numaga; Y Hayashi; M Oshiro; T Yuguchi; T Kaiya
Journal:  Br J Ophthalmol       Date:  2001-01       Impact factor: 4.638

4.  Quantitative evaluation of changes in anterior segment biometry by peripheral laser iridotomy using newly developed scanning peripheral anterior chamber depth analyser.

Authors:  K Kashiwagi; K Abe; S Tsukahara
Journal:  Br J Ophthalmol       Date:  2004-08       Impact factor: 4.638

5.  Longitudinal study of posterior subcapsular opacities using the National Eye Institute computer planimetry system.

Authors:  M L Lopez; V Freidlin; M B Datiles
Journal:  Br J Ophthalmol       Date:  1995-06       Impact factor: 4.638

Review 6.  Biometric Measurement of Anterior Segment: A Review.

Authors:  Bin Liu; Chengwei Kang; Fengzhou Fang
Journal:  Sensors (Basel)       Date:  2020-07-31       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.