Literature DB >> 23878103

Three-dimensional heart locator for whole-heart coronary magnetic resonance angiography.

Mehdi H Moghari1, Sébastien Roujol, Markus Henningsson, Kraig V Kissinger, David Annese, Reza Nezafat, Warren J Manning, Tal Geva, Andrew J Powell.   

Abstract

PURPOSE: Coronary magnetic resonance angiography (MRA) is commonly performed with diaphragmatic navigator (NAV) gating to compensate for respiratory motion, but this approach is inefficient as data must be reacquired when it is outside the acceptance window. We therefore developed and validated a motion compensation technique based on three-dimensional (3D) spatial registration in which data are accepted throughout the respiratory cycle.
METHODS: A novel respiratory motion compensation method was implemented that acquires a low-resolution 3D-image of the heart (3D-LOC) just prior to coronary MRA data acquisition. 3D-LOC volumes were registered to the first 3D-LOC to estimate the respiratory-induced heart motion and to modify the coronary MRA data and reconstruct motion-corrected images. Whole-heart coronary MRA datasets were acquired from nine healthy subjects using a diaphragmatic NAV and using 3D-LOC.
RESULTS: There was no significant difference between the subjective image score of NAV and 3D-LOC in three main coronary branches. The vessel sharpness of 3D-LOC was higher than NAV in the right (0.44 ± 0.08 vs. 0.49 ± 0.08; P = 0.055) and left circumflex arteries (0.49 ± 0.05 vs. 0.52 ± 0.04; P = 0.039). Scan time for 3D-LOC was significantly shorter than NAV (4.3 ± 0.6 vs. 8.3 ± 2.3 min; P = 0.004).
CONCLUSION: Compared to NAV gating, 3D-LOC for coronary MRA reduces scan time by nearly 50% without compromising image quality.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  coronary magnetic resonance angiography; diaphragmatic navigator; motion compensation; respiratory motion

Mesh:

Year:  2013        PMID: 23878103     DOI: 10.1002/mrm.24881

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  3D image-based navigators for coronary MR angiography.

Authors:  Nii Okai Addy; R Reeve Ingle; Jieying Luo; Corey A Baron; Phillip C Yang; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2016-05-13       Impact factor: 4.668

2.  Nonrigid Motion Correction With 3D Image-Based Navigators for Coronary MR Angiography.

Authors:  Jieying Luo; Nii Okai Addy; R Reeve Ingle; Corey A Baron; Joseph Y Cheng; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2016-05-13       Impact factor: 4.668

3.  Three-dimensional heart locator and compressed sensing for whole-heart MR angiography.

Authors:  Mehdi H Moghari; David Annese; Tal Geva; Andrew J Powell
Journal:  Magn Reson Med       Date:  2015-06-10       Impact factor: 4.668

4.  The role of latency period in quality management for free-breathing coronary wall MRI.

Authors:  Kai Lin; Donald M Lloyd-Jones; Ying Liu; Xiaoming Bi; Biao Lu; Debiao Li; James C Carr
Journal:  Int J Cardiovasc Imaging       Date:  2015-01-09       Impact factor: 2.357

5.  ECG and navigator-free four-dimensional whole-heart coronary MRA for simultaneous visualization of cardiac anatomy and function.

Authors:  Jianing Pang; Behzad Sharif; Zhaoyang Fan; Xiaoming Bi; Reza Arsanjani; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-09-12       Impact factor: 4.668

6.  Motion-corrected 3D whole-heart water-fat high-resolution late gadolinium enhancement cardiovascular magnetic resonance imaging.

Authors:  Camila Munoz; Aurelien Bustin; Radhouene Neji; Karl P Kunze; Christoph Forman; Michaela Schmidt; Reza Hajhosseiny; Pier-Giorgio Masci; Martin Zeilinger; Wolfgang Wuest; René M Botnar; Claudia Prieto
Journal:  J Cardiovasc Magn Reson       Date:  2020-07-20       Impact factor: 5.364

7.  Optimized respiratory-resolved motion-compensated 3D Cartesian coronary MR angiography.

Authors:  Teresa Correia; Giulia Ginami; Gastão Cruz; Radhouene Neji; Imran Rashid; René M Botnar; Claudia Prieto
Journal:  Magn Reson Med       Date:  2018-04-22       Impact factor: 4.668

8.  Visualization of coronary arteries in paediatric patients using whole-heart coronary magnetic resonance angiography: comparison of image-navigation and the standard approach for respiratory motion compensation.

Authors:  Mari Nieves Velasco Forte; Israel Valverde; Nanda Prabhu; Teresa Correia; Srinivas Ananth Narayan; Aaron Bell; Sujeev Mathur; Reza Razavi; Tarique Hussain; Kuberan Pushparajah; Markus Henningsson
Journal:  J Cardiovasc Magn Reson       Date:  2019-02-25       Impact factor: 5.364

9.  Diagnostic performance of image navigated coronary CMR angiography in patients with coronary artery disease.

Authors:  Markus Henningsson; Joy Shome; Konstantinos Bratis; Miguel Silva Vieira; Eike Nagel; Rene M Botnar
Journal:  J Cardiovasc Magn Reson       Date:  2017-09-11       Impact factor: 5.364

10.  3D whole-heart isotropic sub-millimeter resolution coronary magnetic resonance angiography with non-rigid motion-compensated PROST.

Authors:  Aurélien Bustin; Imran Rashid; Gastao Cruz; Reza Hajhosseiny; Teresa Correia; Radhouene Neji; Ronak Rajani; Tevfik F Ismail; René M Botnar; Claudia Prieto
Journal:  J Cardiovasc Magn Reson       Date:  2020-04-16       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.