Comparison of PD BLADE with fat saturation (FS), PD FS and T2 3D DESS with water excitation (WE) in detecting articular knee cartilage defects.

Eleftherios Lavdas1, Theofilos Topalzikis, Panayiotis Mavroidis, Ioannis Kyriakis, Violeta Roka, Spiros Kostopoulos, Dimitrios Glotsos, Christos Zilidis, Sotiris Stathakis, Antonios Tsagkalis, Nikos Papanikolaou, Georgios Batsikas, Dimitrios L Arvanitis, Katerina Vassiou.   

Abstract

The purpose of this study, is to compare the sequences: 1) proton density (PD) BLADE (BLADE is a PROPELLER-equivalent implementation of the Siemens Medical System) with fat saturation (FS) coronal (COR), 2) PD FS COR, 3) multi-planar reconstruction (MPR) with 3mm slice thickness and 4) multi-planar reconstruction (MPR) with 1.5mm slice thickness, both from the T2 3D-double-echo steady state (DESS) with water excitation (WE) sagittal (SAG), regarding their abilities to identify changes in the femorotibial condyle cartilage in knee MRI examinations. Thirty three consecutive patients with osteoarthritis (18 females, 15 males; mean age 56years, range 37-71years), who had been routinely scanned for knee examination using the previously mentioned image acquisition techniques, participated in the study. A quantitative analysis was performed based on the relative contrast (ReCON) measurements, which were taken both on normal tissues as well as on pathologies. Additionally, a qualitative analysis was performed by two radiologists. Motion and pulsatile flow artifacts were evaluated. The PD BLADE FS COR sequence produced images of higher contrast between Menisci and Cartilage, Fluid and Cartilage, Pathologies and Cartilage as well as of the Conspicuousness Superficial Cartilage and it was found to be superior to the other sequences (p<0.001). The sequences T2 3D DESS 1.5mm and T2 3D DESS 3mm were significantly superior to the PD BLADE FS COR and the PD FS COR sequences in the visualization of Bone and Cartilage and the Conspicuousness Deep Surface Cartilage. This pattern of results is also confirmed by the quantitative analysis. PD FS BLADE sequences are ideal for the depiction of the cartilage pathologies compared to the conventional PD FS and T2 3D DESS sequences.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  1.5T MRI; BLADE proton density with fat saturation sequences; Cartilage defects; Knee MRI; T2 3D DESS

Mesh:

Year:  2013        PMID: 23876261     DOI: 10.1016/j.mri.2013.06.007

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  3 in total

1.  Comparative study of image quality between axial T2-weighted BLADE and turbo spin-echo MRI of the upper abdomen on 3.0 T.

Authors:  Lin Zhang; ChunMei Tian; PeiYuan Wang; Liang Chen; XiJin Mao; ShanShan Wang; Xu Wang; JingMin Dong; Bin Wang
Journal:  Jpn J Radiol       Date:  2015-08-02       Impact factor: 2.374

2.  Routine clinical knee MR reports: comparison of diagnostic performance at 1.5 T and 3.0 T for assessment of the articular cartilage.

Authors:  Jacob C Mandell; Jeffrey A Rhodes; Nehal Shah; Glenn C Gaviola; Andreas H Gomoll; Stacy E Smith
Journal:  Skeletal Radiol       Date:  2017-07-17       Impact factor: 2.199

3.  Efficient imaging of midbrain nuclei using inverse double-echo steady-state acquisition.

Authors:  Ming-Long Wu; Hing-Chiu Chang; Tzu-Cheng Chao; Nan-Kuei Chen
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.