Literature DB >> 23875135

Arthroscopic hybrid fixation of a tibial eminence fracture in children.

Jong In Kim1, Jae Ho Kwon, Dong Hyun Seo, Shaishav M Soni, Michael Muñoz, Kyung Wook Nha.   

Abstract

The treatment of an anterior cruciate ligament (ACL) avulsion fracture is controversial, especially in skeletally immature patients, because of concerns about physeal damage. To reduce the risk of physeal injury, an arthroscopic technique was performed. A bioabsorbable suture anchor was inserted through anteromedial portals and fixed to a bioabsorbable suture anchor at the center of the fracture bed; it was then passed through the threads at the ACL avulsion fragment and tied with the ACL substance. After this, the avulsion fragment was repaired by an all-inside technique between the distal portion of the ACL and the transverse ligament and periosteum by a suture hook. The arthroscopic hybrid technique using a suture anchor with an all-inside repair is more rigid and safe. In addition, this physeal-sparing fixation is possible in immature patients.

Entities:  

Year:  2013        PMID: 23875135      PMCID: PMC3716210          DOI: 10.1016/j.eats.2012.12.005

Source DB:  PubMed          Journal:  Arthrosc Tech        ISSN: 2212-6287


  7 in total

1.  Biomechanical comparison of three techniques for fixation of tibial avulsion fractures of the anterior cruciate ligament.

Authors:  Yong In; Dai-Soon Kwak; Chan-Woong Moon; Seung-Ho Han; Nam-Yong Choi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-11       Impact factor: 4.342

2.  Arthroscopic fixation of anterior cruciate ligament tibial avulsion fractures using bioabsorbable suture anchors.

Authors:  Yong In; Jung-Man Kim; Young-Kyun Woo; Nam-Yong Choi; Chan-Woong Moon; Min-Woo Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-12-22       Impact factor: 4.342

3.  Physeal sparing arthroscopic fixation of displaced tibial eminence fractures: a new surgical technique.

Authors:  Michael T Hirschmann; Ralph R Mayer; Axel Kentsch; Niklaus F Friederich
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-02-19       Impact factor: 4.342

4.  Arthroscopic transpatellar cannulated screw fixation of tibia eminence fractures in the adult.

Authors:  Kook Hyun Wang; Hyoung Keun Oh; Si Hoon Yoo; Dong Ju Chae; Hyok Woo Nam; Kyung Wook Nha
Journal:  Orthopedics       Date:  2011-03       Impact factor: 1.390

5.  Arthroscopic physeal sparing all inside repair of the tibial avulsion fracture in the anterior cruciate ligament: technical note.

Authors:  Jin Hwan Ahn; Yong Seuk Lee; Dong Hoon Lee; Hae Chan Ha
Journal:  Arch Orthop Trauma Surg       Date:  2007-11-15       Impact factor: 3.067

6.  Arthroscopic fixation of displaced tibial eminence fractures: a new growth plate-sparing method.

Authors:  Jorge R Vega; Luis A Irribarra; Alejandro K Baar; Magaly Iñiguez; Martin Salgado; Natalia Gana
Journal:  Arthroscopy       Date:  2008-08-30       Impact factor: 4.772

7.  Arthroscopic suture fixation of tibial eminence avulsion fractures.

Authors:  Tsan-Wen Huang; Kuo-Yao Hsu; Chun-Ying Cheng; Lih-Huei Chen; Ching-Jen Wang; Yi-Sheng Chan; Wen-Jer Chen
Journal:  Arthroscopy       Date:  2008-08-30       Impact factor: 4.772

  7 in total
  2 in total

1.  Pediatric ACL Injuries: A Review of Current Concepts.

Authors:  Vikas Trivedi; Panna Mishra; Deepankar Verma
Journal:  Open Orthop J       Date:  2017-04-28

2.  Arthroscopic tri-pulley Technology reduction and internal fixation of pediatric Tibial Eminence fracture: a retrospective analysis.

Authors:  Liang Zhang; Li Zhang; Jiang Zheng; Bo Ren; Xin Kang; Xian Zhang; Xiaoqian Dang
Journal:  BMC Musculoskelet Disord       Date:  2020-06-29       Impact factor: 2.362

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.