Literature DB >> 18004575

Arthroscopic physeal sparing all inside repair of the tibial avulsion fracture in the anterior cruciate ligament: technical note.

Jin Hwan Ahn1, Yong Seuk Lee, Dong Hoon Lee, Hae Chan Ha.   

Abstract

We describe a new and effective arthroscopic physeal sparing repair of the tibial eminence avulsion fracture using all an inside repair technique. The treatment of ACL avulsion is controversial, especially in skeletally immature patients, with concerns about physeal damage, and a more reliable way of fixation is still being pursued for small or comminuted fragments. Screw fixation and suture cerclage has some limitations, especially in the small fragment or skeletally immature patients. We fixed avulsion fragment using all inside repair between the distal portion of the ACL and transverse ligament and periosteum. A crescent suture hook loaded with NO. 0 PDS is introduced and the suture hook pierces the transverse intermeniscal ligament and periosteum. The half length of the PDS is now advanced out through the hook and the end is brought out to the anterolateral portal. With the suture hook located intra-articularly and loaded with half the length of the original PDS, the suture hook repierces the transverse intermeniscal ligament at 5 mm on the side and the remaining half length of PDS is now advanced out through the hook and the end is brought out to the anterolateral portal. After that procedure, the suture hook loaded with NO. 0 absorbable Maxon is introduced through the anteromedial portal for the role of shuttle relay. The suture hook pierces the ACL just above the superior border of the avulsion fragment, the Maxon is now advanced out through the hook and the end is brought out to the anterolateral portal. Subsequently, the suture hook is removed and a suture retriever is introduced through the anterolateral portal. PDS and Maxon are held together and retrieved out of the anterolateral portal by the suture retriever at the same time. Our technique has advantages in small comminuted fractures and skeletally immature patients.

Entities:  

Mesh:

Year:  2007        PMID: 18004575     DOI: 10.1007/s00402-007-0506-5

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  11 in total

1.  A comparative study of two methods for treating type III tibial eminence avulsion fracture in adults.

Authors:  Weilin Sang; Libo Zhu; Jinzhong Ma; Haiming Lu; Yinxian Yu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-10       Impact factor: 4.342

2.  Proximal anterior cruciate ligament avulsion treated with TightRope® fixation device.

Authors:  N S Wardle; F S Haddad
Journal:  Ann R Coll Surg Engl       Date:  2012-03       Impact factor: 1.891

3.  Biomechanical comparison of three techniques for fixation of tibial avulsion fractures of the anterior cruciate ligament.

Authors:  Yong In; Dai-Soon Kwak; Chan-Woong Moon; Seung-Ho Han; Nam-Yong Choi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-11       Impact factor: 4.342

4.  Surgical Reduction and Fixation of Tibial Spine Fractures in Children: Multiple Fixation Strategies.

Authors:  Theodore J Ganley; Christopher M Brusalis
Journal:  JBJS Essent Surg Tech       Date:  2016-05-11

5.  Tension band wire fixation for anterior cruciate ligament avulsion fracture: biomechanical comparison of four fixation techniques.

Authors:  Yudong Gan; Dachuan Xu; Jing Ding; Yongqing Xu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-08-24       Impact factor: 4.342

6.  Reliable ligamentous stability and high return-to-sport rates after arthroscopic reduction and internal fixation of tibial eminence fractures.

Authors:  Patricia M Lutz; Stephanie Geyer; Philipp W Winkler; Markus Irger; Daniel P Berthold; Matthias J Feucht; Andreas B Imhoff; Philipp Forkel
Journal:  Arch Orthop Trauma Surg       Date:  2021-05-19       Impact factor: 3.067

7.  Biomechanical comparison of different fixation techniques for reconstruction of tibial avulsion fractures of the anterior cruciate ligament.

Authors:  Marco Ezechieli; Madeline Schäfer; Christoph Becher; Antonios Dratzidis; Richard Glaab; Christian Ryf; Christof Hurschler; Max Ettinger
Journal:  Int Orthop       Date:  2013-03-02       Impact factor: 3.075

8.  Arthroscopic hybrid fixation of a tibial eminence fracture in children.

Authors:  Jong In Kim; Jae Ho Kwon; Dong Hyun Seo; Shaishav M Soni; Michael Muñoz; Kyung Wook Nha
Journal:  Arthrosc Tech       Date:  2013-04-06

9.  Arthroscopic Fixation of Tibial Spine Avulsion Fracture in Open Physis.

Authors:  Varun Chouhan
Journal:  J Orthop Case Rep       Date:  2016 Apr-Jun

10.  Coexistence of Extraskeletal Mesenchymal Chondrosarcoma and Isolated Hemihyperplasia: A Case Report.

Authors:  Nihat Demirhan Demirkiran; Olcay Akdeniz; Onur Hapa; Hasan Havıtçıoğlu
Journal:  J Orthop Case Rep       Date:  2016 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.