Literature DB >> 23868147

Accuracy of vessel-encoded pseudocontinuous arterial spin-labeling in identification of feeding arteries in patients with intracranial arteriovenous malformations.

S L Yu1, R Wang, R Wang, S Wang, Y Q Yao, D Zhang, Y L Zhao, Z T Zuo, R Xue, D J J Wang, J Z Zhao.   

Abstract

BACKGROUND AND
PURPOSE: Identifying feeding arteries of intracranial AVMs is very important for preoperative evaluation. DSA remains the reference standard for diagnosis but is invasive. Our aim was to evaluate the diagnostic accuracy of vessel-encoded pseudocontinuous arterial spin-labeling in identifying feeding arteries of intracranial AVMs by using DSA as the criterion standard.
MATERIALS AND METHODS: Eighteen patients with AVMs were examined with vessel-encoded pseudocontinuous arterial spin-labeling and DSA. Three postlabeling delays (postlabeling delay = 1, 1.3, and 1.6 seconds) were applied in 6 patients, and a single postlabeling delay (1 second) was applied in the remainder. Perfusion-weighted images were decoded into individual vascular territories with standard and relative tagging efficiencies, respectively. The supply fraction of each feeding artery to the AVM was calculated. The within-subject ANOVA was applied to compare supply fractions acquired across 3 postlabeling delays. Receiver operating characteristic analysis curves were calculated to evaluate the diagnostic accuracy of vessel-encoded pseudocontinuous arterial spin-labeling for identifying the feeding arteries of AVMs.
RESULTS: There were no significant differences in supply fractions of the 3 major arteries to AVMs acquired with 3 postlabeling delays (P > .05). For vessel-encoded pseudocontinuous arterial spin-labeling with standard labeling efficiencies, the area under the receiver operating characteristic analysis curve was 0.942. The optimal cutoff of the supply fraction for identifying feeding arteries was 15.17%, and the resulting sensitivity and specificity were 84.62% and 93.33%, respectively. For vessel-encoded pseudocontinuous arterial spin-labeling with relative labeling efficiencies, the area under the receiver operating characteristic analysis curve was 0.957. The optimal cutoff of the supply fraction was 11.73%, which yielded an 89.74% sensitivity and 93.33% specificity.
CONCLUSIONS: The contribution fraction of each feeding artery of the AVM can be reliably estimated by using vessel-encoded pseudocontinuous arterial spin-labeling. Vessel-encoded pseudocontinuous arterial spin-labeling with either standard or relative labeling efficiencies offers a high level of diagnostic accuracy compared with DSA for identifying feeding arteries.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23868147      PMCID: PMC4113209          DOI: 10.3174/ajnr.A3638

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  21 in total

1.  Microsurgery for small arteriovenous malformations of the brain: results in 110 consecutive patients.

Authors:  J H Pik; M K Morgan
Journal:  Neurosurgery       Date:  2000-09       Impact factor: 4.654

2.  Quantifying CBF with pulsed ASL: technical and pulse sequence factors.

Authors:  Eric C Wong
Journal:  J Magn Reson Imaging       Date:  2005-12       Impact factor: 4.813

3.  A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling.

Authors:  Wen-Chau Wu; María Fernández-Seara; John A Detre; Felix W Wehrli; Jiongjiong Wang
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

4.  Surgical management of large AVM's by staged embolization and operative excision.

Authors:  R F Spetzler; N A Martin; L P Carter; R A Flom; P A Raudzens; E Wilkinson
Journal:  J Neurosurg       Date:  1987-07       Impact factor: 5.115

5.  Quantitative assessment of external carotid artery territory supply with modified vessel-encoded arterial spin-labeling.

Authors:  Y Dang; B Wu; Y Sun; D Mo; X Wang; J Zhang; J Fang
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-16       Impact factor: 3.825

Review 6.  Cerebral angiographic risk in mild cerebrovascular disease.

Authors:  G J Hankey; C P Warlow; R J Sellar
Journal:  Stroke       Date:  1990-02       Impact factor: 7.914

7.  Pediatric arteriovenous malformations: a 15-year experience with an emphasis on residual and recurrent lesions.

Authors:  Paul Klimo; Ganesh Rao; Douglas Brockmeyer
Journal:  Childs Nerv Syst       Date:  2006-10-13       Impact factor: 1.475

8.  The measurement of observer agreement for categorical data.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-03       Impact factor: 2.571

9.  Perfusion imaging.

Authors:  J A Detre; J S Leigh; D S Williams; A P Koretsky
Journal:  Magn Reson Med       Date:  1992-01       Impact factor: 4.668

Review 10.  Neurologic complications of cerebral angiography: prospective analysis of 2,899 procedures and review of the literature.

Authors:  Robert A Willinsky; Steve M Taylor; Karel TerBrugge; Richard I Farb; George Tomlinson; Walter Montanera
Journal:  Radiology       Date:  2003-03-13       Impact factor: 11.105

View more
  5 in total

Review 1.  Arterial spin labeling for the measurement of cerebral perfusion and angiography.

Authors:  Peter Jezzard; Michael A Chappell; Thomas W Okell
Journal:  J Cereb Blood Flow Metab       Date:  2017-11-23       Impact factor: 6.200

2.  Planning-free cerebral blood flow territory mapping in patients with intracranial arterial stenosis.

Authors:  Daniel F Arteaga; Megan K Strother; L Taylor Davis; Matthew R Fusco; Carlos C Faraco; Brent A Roach; Allison O Scott; Manus J Donahue
Journal:  J Cereb Blood Flow Metab       Date:  2016-01-01       Impact factor: 6.200

Review 3.  A neuroradiologist's guide to arterial spin labeling MRI in clinical practice.

Authors:  M Grade; J A Hernandez Tamames; F B Pizzini; E Achten; X Golay; M Smits
Journal:  Neuroradiology       Date:  2015-09-09       Impact factor: 2.804

4.  Non-invasive qualitative and semiquantitative presurgical investigation of the feeding vasculature to intracranial meningiomas using superselective arterial spin labeling.

Authors:  Ulf Jensen-Kondering; Michael Helle; Thomas Lindner; Olav Jansen; Arya Nabavi
Journal:  PLoS One       Date:  2019-04-09       Impact factor: 3.240

5.  Effect of head-down tilt on clinical outcome and cerebral perfusion in ischemic stroke patients: A case series.

Authors:  Zi-Ai Zhao; Nan-Nan Zhang; Lin Tao; Yu Cui; Meng Li; Shou-Liang Qi; Hui-Sheng Chen
Journal:  Front Neurol       Date:  2022-09-26       Impact factor: 4.086

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.