Literature DB >> 23860134

Osteosynthesis of unstable intracapsular femoral neck fracture by dynamic locking plate or screw fixation: early results.

Ran Thein1, Amir Herman, Paz Kedem, Aharon Chechik, Nachshon Shazar.   

Abstract

OBJECTIVES: The purpose of this study was to compare the postoperative radiologic and clinical outcomes of telescopic femur neck screws and small locking plate device (Targon FN) (group 1) with multiple cancellous screws (group 2) for displaced intracapsular femoral neck fractures.
DESIGN: Comparison of a prospective collected data to a historical control group (retrospective).
SETTING: One community teaching hospital. PATIENTS: Seventy-eight patients (group 1, 31; group 2, 47) underwent reduction and internal fixation of displaced intracapsular femoral neck fractures with either Targon FN device or multiple cancellous screws from March 2000 to July 2010. Their mean age was 53.7 years (SD: 16.4), and the mean follow-up period was 28.6 months. MAIN OUTCOME MEASURES: Treatment failure was considered to be either a nonunion, osteonecrosis, or revision surgery of any type. Treatment was regarded as successful in patients who did not show failure and had at least 1-year follow-up.
RESULTS: One patient in group 1 (3.2%) and 22 (46.8%) in group 2 had a nonunion (P = 0.0001). Four (12.9%) group 1 patients and 16 (34.0%) group 2 patients underwent revision surgery (P = 0.036). Four (12.9%) patients in group 1 and 4 (8.5%) group 2 patients had osteonecrosis of the femoral head (P = 0.531). Multivariate logistic regression showed that internal fixation by the fixed-angle fixation device decreased the odds ratio for overall complication by a factor of 0.23, for example, by 77% (P = 0.018).
CONCLUSIONS: Performing internal fixation by a fixed-angle fixation device decreased nonunion rates and revision rates. It did not affect the rate of osteonecrosis. LEVEL OF EVIDENCE: Therapeutic level III. See instructions for authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2014        PMID: 23860134     DOI: 10.1097/BOT.0b013e3182a225fa

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  12 in total

Review 1.  [Complications after osteosynthesis of the proximal femur].

Authors:  M J Raschke; N Alt
Journal:  Orthopade       Date:  2014-01       Impact factor: 1.087

2.  [Joint-preserving treatment of medial femoral neck fractures with an angular stable implant].

Authors:  M Saß; T Mittlmeier
Journal:  Oper Orthop Traumatol       Date:  2016-05-03       Impact factor: 1.154

3.  The Telescoping Hip Plate for Treatment of Femoral Neck Fracture: Design Rationale, Surgical Technique and Early Results.

Authors:  Michael Willey; Matthew L Welsh; Travis S Roth; Kenneth J Koval; James V Nepola
Journal:  Iowa Orthop J       Date:  2018

4.  Incidence of and Factors Influencing Femoral Neck Shortening in Elderly Patients After Fracture Fixation with Multiple Cancellous Screws.

Authors:  Xiaobing Chen; Jianzheng Zhang; Xiinling Wang; Jixin Ren; Zhi Liu
Journal:  Med Sci Monit       Date:  2017-03-26

5.  Suboptimal outcomes after closed reduction and internal fixation of displaced femoral neck fractures in middle-aged patients: is internal fixation adequate in this age group?

Authors:  Cheng-Tzu Wang; Jia-Wan Chen; Karl Wu; Chiang-Sang Chen; Wen-Chih Chen; Jwo-Luen Pao; Chih-Hung Chang; Tsung-Yu Lan
Journal:  BMC Musculoskelet Disord       Date:  2018-06-09       Impact factor: 2.362

6.  Technology of percutaneous cannulated screw implantation using screw view model of navigation in Garden type I of femoral neck fracture: A case report.

Authors:  Tong Yu; Bao-Ming Yuan; Xi-Wen Zhang; Dong-Sheng Wang; Yi-Kun Jiang; Rong-Peng Dong; Ming-Yang Kang; Xin Zhao; Jian-Wu Zhao
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

Review 7.  Is dynamic locking plate superior than other implants for intracapsular hip fracture: A meta-analysis.

Authors:  Tao Li; Qing-Song Zhang
Journal:  Medicine (Baltimore)       Date:  2018-11       Impact factor: 1.889

8.  Comparison of early complications between the use of a cannulated screw locking plate and multiple cancellous screws in the treatment of displaced intracapsular hip fractures in young adults: a randomized controlled clinical trial.

Authors:  Zhiqiang Wang; Yi Yin; Qingshan Li; Guanjun Sun; Xu Peng; Hua Yin; Yongjie Ye
Journal:  J Orthop Surg Res       Date:  2018-08-13       Impact factor: 2.359

9.  Femur neck fracture in young adults, is it really an urgent surgery indication: retrospective clinical study.

Authors:  Seyitali Gumustas; Haci Bayram Tosun; Mehmet Isyar; Sancar Serbest; Kadir Oznam; Güven Bulut
Journal:  Pan Afr Med J       Date:  2018-06-12

10.  The effect of bone morphogenetic protein 2 composite materials combined with cannulated screws in treatment of acute displaced femoral neck fractures.

Authors:  Hongwei Gao; Deguo Xing; Zhonghao Liu; Jiachun Zheng; Zhenggang Xiong; Mingzhi Gong; Lan Liu
Journal:  Medicine (Baltimore)       Date:  2020-02       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.