Literature DB >> 23857135

Intravascular enhancement with identical iodine delivery rate using different iodine contrast media in a circulation phantom.

Casper Mihl1, Joachim E Wildberger, Tomas Jurencak, Michael J Yanniello, Estelle C Nijssen, John F Kalafut, Georgi Nalbantov, Georg Mühlenbruch, Florian F Behrendt, Marco Das.   

Abstract

PURPOSE: Both iodine delivery rate (IDR) and iodine concentration are decisive factors for vascular enhancement in computed tomographic angiography. It is unclear, however, whether the use of high-iodine concentration contrast media is beneficial to lower iodine concentrations when IDR is kept identical. This study evaluates the effect of using different iodine concentrations on intravascular attenuation in a circulation phantom while maintaining a constant IDR.
MATERIALS AND METHODS: A circulation phantom with a low-pressure venous compartment and a high-pressure arterial compartment simulating physiological circulation parameters was used (heart rate, 60 beats per minute; stroke volume, 60 mL; blood pressure, 120/80 mm Hg). Maintaining a constant IDR (2.0 g/s) and a constant total iodine load (20 g), prewarmed (37°C) contrast media with differing iodine concentrations (240-400 mg/mL) were injected into the phantom using a double-headed power injector. Serial computed tomographic scans at the level of the ascending aorta (AA), the descending aorta (DA), and the left main coronary artery (LM) were obtained. Total amount of contrast volume (milliliters), iodine delivery (grams of iodine), peak flow rate (milliliter per second), and intravascular pressure (pounds per square inch) were monitored using a dedicated data acquisition program. Attenuation values in the AA, the DA, and the LM were constantly measured (Hounsfield unit [HU]). In addition, time-enhancement curves, aortic peak enhancement, and time to peak were determined.
RESULTS: All contrast injection protocols resulted in similar attenuation values: the AA (516 [11] to 531 [37] HU), the DA (514 [17] to 531 [32] HU), and the LM (490 [10] to 507 [17] HU). No significant differences were found between the AA, the DA, and the LM for either peak enhancement (all P > 0.05) or mean time to peak (AA, 19.4 [0.58] to 20.1 [1.05] seconds; DA, 21.1 [1.0] to 21.4 [1.15] seconds; LM, 19.8 [0.58] to 20.1 [1.05] seconds).
CONCLUSIONS: This phantom study demonstrates that constant injection parameters (IDR, overall iodine load) lead to robust enhancement patterns, regardless of the contrast material used. Higher iodine concentration itself does not lead to higher attenuation levels. These results may stimulate a shift in paradigm toward clinical usage of contrast media with lower iodine concentrations (eg, 240 mg iodine/mL) in individual tailored contrast protocols. The use of low-iodine concentration contrast media is desirable because of the lower viscosity and the resulting lower injection pressure.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23857135     DOI: 10.1097/RLI.0b013e31829979e8

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  13 in total

1.  Individually tailored contrast enhancement in CT pulmonary angiography.

Authors:  Babs M F Hendriks; Madeleine Kok; Casper Mihl; Sebastiaan C A M Bekkers; Joachim E Wildberger; Marco Das
Journal:  Br J Radiol       Date:  2016-01-22       Impact factor: 3.039

2.  Contrast agent concentration optimization in CTA using low tube voltage and dual-energy CT in multiple vendors: a phantom study.

Authors:  Robbert W van Hamersvelt; Nienke G Eijsvoogel; Casper Mihl; Pim A de Jong; Arnold M R Schilham; Nico Buls; Marco Das; Tim Leiner; Martin J Willemink
Journal:  Int J Cardiovasc Imaging       Date:  2018-03-08       Impact factor: 2.357

3.  Contrast media injection protocol optimization for dual-energy coronary CT angiography: results from a circulation phantom.

Authors:  Domenico De Santis; Damiano Caruso; U Joseph Schoepf; Marwen Eid; Moritz H Albrecht; Taylor M Duguay; Akos Varga-Szemes; Andrea Laghi; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2018-02-27       Impact factor: 5.315

4.  Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography.

Authors:  Yan Xing; Gulina Azati; Cun-xue Pan; Jun Dang; Sailendra Jha; Wen-ya Liu
Journal:  PLoS One       Date:  2015-07-13       Impact factor: 3.240

5.  The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography.

Authors:  Toon Van Cauteren; Gert Van Gompel; Kaoru Tanaka; Douwe E Verdries; Dries Belsack; Koenraad H Nieboer; Inneke Willekens; Paul Evans; Sven Macholl; Guy Verfaillie; Steven Droogmans; Johan de Mey; Nico Buls
Journal:  Biomed Res Int       Date:  2017-05-23       Impact factor: 3.411

6.  Impact of CT Injector Technology and Contrast Media Viscosity on Vascular Enhancement: Evaluation in a Circulation Phantom.

Authors:  Michael McDermott; Corey Kemper; William Barone; Gregor Jost; Jan Endrikat
Journal:  Br J Radiol       Date:  2020-02-20       Impact factor: 3.039

7.  Development and evaluation of a CEACAM6-targeting theranostic nanomedicine for photoacoustic-based diagnosis and chemotherapy of metastatic cancer.

Authors:  Hohyeon Lee; Yongho Jang; Suhyun Park; Hyejin Jang; Eun-Joo Park; Hyun Jung Kim; Hyuncheol Kim
Journal:  Theranostics       Date:  2018-07-30       Impact factor: 11.556

Review 8.  Vascular CT and MRI: a practical guide to imaging protocols.

Authors:  D J Murphy; A Aghayev; M L Steigner
Journal:  Insights Imaging       Date:  2018-03-14

9.  Impact of iodine concentration and scan parameters on image quality, contrast enhancement and radiation dose in thoracic CT.

Authors:  Marian S Solbak; Mette K Henning; Andrew England; Anne C Martinsen; Trond M Aaløkken; Safora Johansen
Journal:  Eur Radiol Exp       Date:  2020-09-11

10.  Personalization of CM Injection Protocols in Coronary Computed Tomographic Angiography (People CT Trial).

Authors:  N G Eijsvoogel; B M F Hendriks; P Nelemans; C Mihl; J Willigers; B Martens; J E Wildberger; M Das
Journal:  Contrast Media Mol Imaging       Date:  2020-01-17       Impact factor: 3.161

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.