Hand rub dose needed for a single disinfection varies according to product: a bias in benchmarking using indirect hand hygiene indicator.

Raphaële Girard1, Martine Aupee, Martine Erb, Anne Bettinger, Alice Jouve.   

Abstract

BACKGROUND: The 3ml volume currently used as the hand hygiene (HH) measure has been explored as the pertinent dose for an indirect indicator of HH compliance. A multicenter study was conducted in order to ascertain the required dose using different products.
METHOD: The average contact duration before drying was measured and compared with references. Effective hand coverage had to include the whole hand and the wrist. Two durations were chosen as points of reference: 30s, as given by guidelines, and the duration validated by the European standard EN 1500. Each product was to be tested, using standardized procedures, by three nosocomial infection prevention teams, for three different doses (3, 2 and 1.5ml).
RESULTS: Data from 27 products and 1706 tests were analyzed. Depending on the product, the dose needed to ensure a 30-s contact duration in 75% of tests ranging from 2ml to more than 3ml, and to ensure a contact duration exceeding the EN 1500 times in 75% of tests ranging from 1.5ml to more than 3ml. The aftermath interpretation is the following: if different products are used, the volume utilized does not give an unbiased estimation of the HH compliance. Other compliance evaluation methods remain necessary for efficient benchmarking.
Copyright © 2012 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Benchmarking; Compliance; Hand hygiene; Hand rub

Mesh:

Substances:

Year:  2012        PMID: 23856500     DOI: 10.1016/j.jegh.2012.10.001

Source DB:  PubMed          Journal:  J Epidemiol Glob Health        ISSN: 2210-6006


  4 in total

1.  How long is enough? Identification of product dry-time as a primary driver of alcohol-based hand rub efficacy.

Authors:  Miranda Suchomel; Rachel A Leslie; Albert E Parker; David R Macinga
Journal:  Antimicrob Resist Infect Control       Date:  2018-05-16       Impact factor: 4.887

2.  Systematic review on factors influencing the effectiveness of alcohol-based hand rubbing in healthcare.

Authors:  Lesley Price; Lucyna Gozdzielewska; Julius Cesar Alejandre; Annelysse Jorgenson; Emma Stewart; Didier Pittet; Jacqui Reilly
Journal:  Antimicrob Resist Infect Control       Date:  2022-01-24       Impact factor: 4.887

3.  Development of amoxicillin resistance in Escherichia coli after exposure to remnants of a non-related phagemid-containing E. coli: an exploratory study.

Authors:  Joep J J M Stohr; Marjolein F Q Kluytmans-van den Bergh; Carlo J M M Verhulst; John W A Rossen; Jan A J W Kluytmans
Journal:  Antimicrob Resist Infect Control       Date:  2020-03-16       Impact factor: 4.887

4.  Universal or targeted approach to prevent the transmission of extended-spectrum beta-lactamase-producing Enterobacteriaceae in intensive care units: a cost-effectiveness analysis.

Authors:  Lidia Kardaś-Słoma; Jean-Christophe Lucet; Anne Perozziello; Camille Pelat; Gabriel Birgand; Etienne Ruppé; Pierre-Yves Boëlle; Antoine Andremont; Yazdan Yazdanpanah
Journal:  BMJ Open       Date:  2017-11-03       Impact factor: 2.692

  4 in total