Literature DB >> 23853374

Mechanically flexible wireless multisensor platform for human physical activity and vitals monitoring.

Y Chuo, M Marzencki, B Hung, C Jaggernauth, K Tavakolian, P Lin, B Kaminska.   

Abstract

Practical usability of the majority of current wearable body sensor systems for multiple parameter physiological signal acquisition is limited by the multiple physical connections between sensors and the data-acquisition modules. In order to improve the user comfort and enable the use of these types of systems on active mobile subjects, we propose a wireless body sensor system that incorporates multiple sensors on a single node. This multisensor node includes signal acquisition, processing, and wireless data transmission fitted on multiple layers of a thin flexible substrate with a very small footprint. Considerations for design include size, form factor, reliable body attachment, good signal coupling, low power consumption, and user convenience. The prototype device measures 55 15 mm and is 3 mm thick. The unit is attached to the patient's chest, and is capable of performing simultaneous measurements of parameters, such as body motion, activity intensity, tilt, respiration, cardiac vibration, cardiac potential (ECG), heart rate, and body surface temperature. In this paper, we discuss the architecture of this system, including the multisensor hardware, the firmware, a mobile-phone receiver unit, and assembly of the first proof-of-concept prototype. Preliminary performance results on key elements of the system, such as power consumption, wireless range, algorithm efficiency, ECG signal quality for heart-rate calculations, as well as synchronous ECG and body activity signals are also presented.

Entities:  

Year:  2010        PMID: 23853374     DOI: 10.1109/TBCAS.2010.2052616

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  11 in total

1.  Automatic Detection of Seismocardiogram Sensor Misplacement for Robust Pre-Ejection Period Estimation in Unsupervised Settings.

Authors:  Hazar Ashouri; Omer T Inan
Journal:  IEEE Sens J       Date:  2017-05-04       Impact factor: 3.301

Review 2.  Unobtrusive sensing and wearable devices for health informatics.

Authors:  Ya-Li Zheng; Xiao-Rong Ding; Carmen Chung Yan Poon; Benny Ping Lai Lo; Heye Zhang; Xiao-Lin Zhou; Guang-Zhong Yang; Ni Zhao; Yuan-Ting Zhang
Journal:  IEEE Trans Biomed Eng       Date:  2014-05       Impact factor: 4.538

3.  Classifying sitting, standing, and walking using plantar force data.

Authors:  Kohle J Merry; Evan Macdonald; Megan MacPherson; Omar Aziz; Edward Park; Michael Ryan; Carolyn J Sparrey
Journal:  Med Biol Eng Comput       Date:  2021-01-08       Impact factor: 2.602

4.  A Wearable Patch to Enable Long-Term Monitoring of Environmental, Activity and Hemodynamics Variables.

Authors:  Mozziyar Etemadi; Omer T Inan; J Alex Heller; Sinan Hersek; Liviu Klein; Shuvo Roy
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2015-05-12       Impact factor: 3.833

5.  Stretchable printed device for the simultaneous sensing of temperature and strain validated in a mouse wound healing model.

Authors:  Manoj Jose; Annelies Bronckaers; Rachith Shanivarasanthe Nithyananda Kumar; Dieter Reenaers; Thijs Vandenryt; Ronald Thoelen; Wim Deferme
Journal:  Sci Rep       Date:  2022-06-16       Impact factor: 4.996

6.  Automatic Identification of Systolic Time Intervals in Seismocardiogram.

Authors:  Ghufran Shafiq; Sivanagaraja Tatinati; Wei Tech Ang; Kalyana C Veluvolu
Journal:  Sci Rep       Date:  2016-11-22       Impact factor: 4.379

7.  Epidermal mechano-acoustic sensing electronics for cardiovascular diagnostics and human-machine interfaces.

Authors:  Yuhao Liu; James J S Norton; Raza Qazi; Zhanan Zou; Kaitlyn R Ammann; Hank Liu; Lingqing Yan; Phat L Tran; Kyung-In Jang; Jung Woo Lee; Douglas Zhang; Kristopher A Kilian; Sung Hee Jung; Timothy Bretl; Jianliang Xiao; Marvin J Slepian; Yonggang Huang; Jae-Woong Jeong; John A Rogers
Journal:  Sci Adv       Date:  2016-11-16       Impact factor: 14.136

8.  A Flexible and Wearable Human Stress Monitoring Patch.

Authors:  Sunghyun Yoon; Jai Kyoung Sim; Young-Ho Cho
Journal:  Sci Rep       Date:  2016-03-23       Impact factor: 4.379

9.  An Enhanced Method to Estimate Heart Rate from Seismocardiography via Ensemble Averaging of Body Movements at Six Degrees of Freedom.

Authors:  Hyunwoo Lee; Hana Lee; Mincheol Whang
Journal:  Sensors (Basel)       Date:  2018-01-15       Impact factor: 3.576

10.  Electrical extraction of piezoelectric constants.

Authors:  Mahmoud Al Ahmad; Areen Allataifeh
Journal:  Heliyon       Date:  2018-11-07
View more