Literature DB >> 23853336

A sub-mW fully-integrated pulse oximeter front-end.

Konstantinos N Glaros1, Emmanuel M Drakakis.   

Abstract

This paper presents the implementation of the first fully integrated pulse oximeter front-end with a power consumption lower than 1 mW. This is enabled by system- and block-level noise optimisation, also detailed in the manuscript. The proposed design features an analogue feedback loop that enables fast and accurate regulation of the detected photocurrent level and a serial-to-parallel interface allowing for extensive programmability of several operation parameters. The front-end was fabricated in the AMS 0.35 μm technology and occupies an area of 1.35 mm(2). Extensive measured results, both electrical and physiological from human subjects are reported, demonstrating an estimated SNR of 39 dB and ability to detect 2% changes in SpO2, similar to commercial pulse oximeters. This is despite the constrained power consumption which amounts to 0.31 mW for the LEDs and 0.53 mW for the rest of the front-end from a 3.3 V supply. Statistical results from 20 chips verify good matching across the Red and Infrared channels of the front-end and the accurate operation of the proposed analogue feedback loop.

Entities:  

Mesh:

Year:  2013        PMID: 23853336     DOI: 10.1109/TBCAS.2012.2200677

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  6 in total

1.  Wearables for the Next Pandemic.

Authors:  Ava Hedayatipour; Nicole Mcfarlane
Journal:  IEEE Access       Date:  2020-10-06       Impact factor: 3.367

Review 2.  Emerging point-of-care technologies for anemia detection.

Authors:  Ran An; Yuning Huang; Yuncheng Man; Russell W Valentine; Erdem Kucukal; Utku Goreke; Zoe Sekyonda; Connie Piccone; Amma Owusu-Ansah; Sanjay Ahuja; Jane A Little; Umut A Gurkan
Journal:  Lab Chip       Date:  2021-05-18       Impact factor: 6.799

3.  A Single-Chip CMOS Pulse Oximeter with On-Chip Lock-In Detection.

Authors:  Diwei He; Stephen P Morgan; Dimitrios Trachanis; Jan van Hese; Dimitris Drogoudis; Franco Fummi; Francesco Stefanni; Valerio Guarnieri; Barrie R Hayes-Gill
Journal:  Sensors (Basel)       Date:  2015-07-14       Impact factor: 3.576

4.  High-Performance Bioinstrumentation for Real-Time Neuroelectrochemical Traumatic Brain Injury Monitoring.

Authors:  Konstantinos I Papadimitriou; Chu Wang; Michelle L Rogers; Sally A N Gowers; Chi L Leong; Martyn G Boutelle; Emmanuel M Drakakis
Journal:  Front Hum Neurosci       Date:  2016-05-19       Impact factor: 3.169

5.  Traumatic brain injury neuroelectrochemical monitoring: behind-the-ear micro-instrument and cloud application.

Authors:  Momen K Tageldeen; Sally A N Gowers; Chi L Leong; Martyn G Boutelle; Emmanuel M Drakakis
Journal:  J Neuroeng Rehabil       Date:  2020-08-21       Impact factor: 4.262

6.  In Vivo Evaluation of a Subcutaneously Injectable Implant with a Low-Power Photoplethysmography ASIC for Animal Monitoring.

Authors:  Jose Manuel Valero-Sarmiento; Parvez Ahmmed; Alper Bozkurt
Journal:  Sensors (Basel)       Date:  2020-12-21       Impact factor: 3.576

  6 in total