Literature DB >> 23853280

Biocompatible, high precision, wideband, improved Howland current source with lead-lag compensation.

A S Tucker1, R M Fox, R J Sadleir.   

Abstract

The Howland current pump is a popular bioelectrical circuit, useful for delivering precise electrical currents. In applications requiring high precision delivery of alternating current to biological loads, the output impedance of the Howland is a critical figure of merit that limits the precision of the delivered current when the load changes. We explain the minimum operational amplifier requirements to meet a target precision over a wide bandwidth. We also discuss effective compensation strategies for achieving stability without sacrificing high frequency output impedance. A current source suitable for Electrical Impedance Tomography (EIT) was simulated using a SPICE model, and built to verify stable operation. This current source design had stable output impedance of 3.3 MΩ up to 200 kHz, which provides 80 dB precision for our EIT application. We conclude by noting the difficulty in measuring the output impedance, and advise verifying the plausibility of measurements against theoretical limitations.

Mesh:

Year:  2013        PMID: 23853280     DOI: 10.1109/TBCAS.2012.2199114

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  7 in total

1.  DSP-based current source for electrical impedance tomography.

Authors:  Gary J Saulnier; Ahmed Abdelwahab; Omid Rajabi Shishvan
Journal:  Physiol Meas       Date:  2020-06-30       Impact factor: 2.833

2.  Florida research open-source synchronization tool (FROST) for electrophysiology experiments.

Authors:  Jose D Alcantara; Robert S Eisinger; Enrico Opri; Madison Kelberman; Jackson N Cagle; Julieth Gomez; Kelly D Foote; Michael S Okun; Aysegul Gunduz
Journal:  J Neurosci Methods       Date:  2020-06-01       Impact factor: 2.390

3.  Design and Implementation of a Portable Impedance Cardiography System for Noninvasive Stroke Volume Monitoring.

Authors:  Hassan Yazdanian; Amin Mahnam; Mehdi Edrisi; Morteza Abdar Esfahani
Journal:  J Med Signals Sens       Date:  2016 Jan-Mar

4.  Smart Bioimpedance Spectroscopy Device for Body Composition Estimation.

Authors:  David Naranjo-Hernández; Javier Reina-Tosina; Laura M Roa; Gerardo Barbarov-Rostán; Nuria Aresté-Fosalba; Alfonso Lara-Ruiz; Pilar Cejudo-Ramos; Francisco Ortega-Ruiz
Journal:  Sensors (Basel)       Date:  2019-12-21       Impact factor: 3.576

5.  A Low-Power Stable Wideband Current Source for Acupuncture Point Skin Impedance Measurements.

Authors:  Changpei Qiu; Tianxia Zhao; Qiuping Li; Xin'an Wang; Kanglin Xiao; Bo Wang
Journal:  J Healthc Eng       Date:  2021-01-06       Impact factor: 2.682

6.  Design of Howland Current Sources Using Differential Evolution Optimization.

Authors:  Kaue Felipe Morcelles; Lucas Hermann Negri; Pedro Bertemes-Filho
Journal:  J Electr Bioimpedance       Date:  2020-12-31

7.  Design of Current Sources for Load Common Mode Optimization.

Authors:  Vinicius G Sirtoli; Kaue F Morcelles; Volney C Vincence
Journal:  J Electr Bioimpedance       Date:  2018-12-19
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.