Literature DB >> 23853148

A wireless reflectance pulse oximeter with digital baseline control for unfiltered photoplethysmograms.

Kejia Li1, Steve Warren.   

Abstract

Pulse oximeters are central to the move toward wearable health monitoring devices and medical electronics either hosted by, e.g., smart phones or physically embedded in their design. This paper presents a small, low-cost pulse oximeter design appropriate for wearable and surface-based applications that also produces quality, unfiltered photo-plethysmograms (PPGs) ideal for emerging diagnostic algorithms. The design's "filter-free" embodiment, which employs only digital baseline subtraction as a signal compensation mechanism, distinguishes it from conventional pulse oximeters that incorporate filters for signal extraction and noise reduction. This results in high-fidelity PPGs with thousands of peak-to-peak digitization levels that are sampled at 240 Hz to avoid noise aliasing. Electronic feedback controls make these PPGs more resilient in the face of environmental changes (e.g., the device can operate in full room light), and data stream in real time across either a ZigBee wireless link or a wired USB connection to a host. On-board flash memory is available for store-and-forward applications. This sensor has demonstrated an ability to gather high-integrity data at fingertip, wrist, earlobe, palm, and temple locations from a group of 48 subjects (20 to 64 years old).

Mesh:

Substances:

Year:  2012        PMID: 23853148     DOI: 10.1109/TBCAS.2011.2167717

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  11 in total

1.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

2.  Motion and Noise Artifact-Resilient Atrial Fibrillation Detection using a Smartphone.

Authors:  Jo Woon Chong; Chae Ho Cho; Fatemehsadat Tabei; Duy Le-Anh; Nada Esa; David D McManus; Ki H Chon
Journal:  IEEE J Emerg Sel Top Circuits Syst       Date:  2018-03-22       Impact factor: 3.916

3.  A Single-Chip CMOS Pulse Oximeter with On-Chip Lock-In Detection.

Authors:  Diwei He; Stephen P Morgan; Dimitrios Trachanis; Jan van Hese; Dimitris Drogoudis; Franco Fummi; Francesco Stefanni; Valerio Guarnieri; Barrie R Hayes-Gill
Journal:  Sensors (Basel)       Date:  2015-07-14       Impact factor: 3.576

Review 4.  Wearable Sensors for Remote Health Monitoring.

Authors:  Sumit Majumder; Tapas Mondal; M Jamal Deen
Journal:  Sensors (Basel)       Date:  2017-01-12       Impact factor: 3.576

5.  A novel diversity method for smartphone camera-based heart rhythm signals in the presence of motion and noise artifacts.

Authors:  Fatemehsadat Tabei; Rifat Zaman; Kamrul H Foysal; Rajnish Kumar; Yeesock Kim; Jo Woon Chong
Journal:  PLoS One       Date:  2019-06-19       Impact factor: 3.240

6.  Reflectance-Based Organic Pulse Meter Sensor for Wireless Monitoring of Photoplethysmogram Signal.

Authors:  Fahed Elsamnah; Anubha Bilgaiyan; Muhamad Affiq; Chang-Hoon Shim; Hiroshi Ishidai; Reiji Hattori
Journal:  Biosensors (Basel)       Date:  2019-07-10

Review 7.  Wearable Sensors Incorporating Compensatory Reserve Measurement for Advancing Physiological Monitoring in Critically Injured Trauma Patients.

Authors:  Victor A Convertino; Steven G Schauer; Erik K Weitzel; Sylvain Cardin; Mark E Stackle; Michael J Talley; Michael N Sawka; Omer T Inan
Journal:  Sensors (Basel)       Date:  2020-11-10       Impact factor: 3.576

8.  Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph.

Authors:  Kristen M Warren; Joshua R Harvey; Ki H Chon; Yitzhak Mendelson
Journal:  Sensors (Basel)       Date:  2016-03-07       Impact factor: 3.576

9.  A Smart Pillow for Health Sensing System Based on Temperature and Humidity Sensors.

Authors:  Songsheng Li; Christopher Chiu
Journal:  Sensors (Basel)       Date:  2018-10-29       Impact factor: 3.576

10.  Non-invasive evaluation of coronary heart disease in patients with chronic kidney disease using photoplethysmography.

Authors:  Turgay Saritas; Ruth Greber; Boudewijn Venema; Victor G Puelles; Sabine Ernst; Vladimir Blazek; Jürgen Floege; Steffen Leonhardt; Georg Schlieper
Journal:  Clin Kidney J       Date:  2019-01-25
View more