Literature DB >> 23852744

An Electronic Patch for wearable health monitoring by reflectance pulse oximetry.

Rasmus G Haahr1, Sune B Duun, Mette H Toft, Bo Belhage, Jan Larsen, Karen Birkelund, Erik V Thomsen.   

Abstract

We report the development of an Electronic Patch for wearable health monitoring. The Electronic Patch is a new health monitoring system incorporating biomedical sensors, microelectronics, radio frequency (RF) communication, and a battery embedded in a 3-dimensional hydrocolloid polymer. In this paper the Electronic Patch is demonstrated with a new optical biomedical sensor for reflectance pulse oximetry so that the Electronic Patch in this case can measure the pulse and the oxygen saturation. The reflectance pulse oximetry solution is based on a recently developed annular backside silicon photodiode to enable low power consumption by the light emitting components. The Electronic Patch has a disposable part of soft adhesive hydrocolloid polymer and a reusable part of hard polylaurinlactam. The disposable part contains the battery. The reusable part contains the reflectance pulse oximetry sensor and microelectronics. The reusable part is 'clicked' into the disposable part when the patch is prepared for use. The patch has a size of 88 mm by 60 mm and a thickness of 5 mm.

Entities:  

Mesh:

Year:  2012        PMID: 23852744     DOI: 10.1109/TBCAS.2011.2164247

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  10 in total

1.  Developing a Wireless, High Precision and Processing Speed Pulse Monitoring Headset Using Photoplethysmography.

Authors:  Yunhui Jiang; Jian Tang; Xiaoliang Wang; Chao Shen
Journal:  IEEE J Transl Eng Health Med       Date:  2017-10-20       Impact factor: 3.316

2.  A Single-Chip CMOS Pulse Oximeter with On-Chip Lock-In Detection.

Authors:  Diwei He; Stephen P Morgan; Dimitrios Trachanis; Jan van Hese; Dimitris Drogoudis; Franco Fummi; Francesco Stefanni; Valerio Guarnieri; Barrie R Hayes-Gill
Journal:  Sensors (Basel)       Date:  2015-07-14       Impact factor: 3.576

Review 3.  Wearable Sensors for Remote Health Monitoring.

Authors:  Sumit Majumder; Tapas Mondal; M Jamal Deen
Journal:  Sensors (Basel)       Date:  2017-01-12       Impact factor: 3.576

4.  A flexible organic reflectance oximeter array.

Authors:  Yasser Khan; Donggeon Han; Adrien Pierre; Jonathan Ting; Xingchun Wang; Claire M Lochner; Gianluca Bovo; Nir Yaacobi-Gross; Chris Newsome; Richard Wilson; Ana C Arias
Journal:  Proc Natl Acad Sci U S A       Date:  2018-11-07       Impact factor: 11.205

Review 5.  Recent Developments in Printing Flexible and Wearable Sensing Electronics for Healthcare Applications.

Authors:  Saleem Khan; Shawkat Ali; Amine Bermak
Journal:  Sensors (Basel)       Date:  2019-03-11       Impact factor: 3.576

Review 6.  Recent Progress in Wearable Biosensors: From Healthcare Monitoring to Sports Analytics.

Authors:  Shun Ye; Shilun Feng; Liang Huang; Shengtai Bian
Journal:  Biosensors (Basel)       Date:  2020-12-15

7.  Neonatal wearable device for colorimetry-based real-time detection of jaundice with simultaneous sensing of vitals.

Authors:  Go Inamori; Umihiro Kamoto; Fumika Nakamura; Yutaka Isoda; Azusa Uozumi; Ryosuke Matsuda; Masaki Shimamura; Yusuke Okubo; Shuichi Ito; Hiroki Ota
Journal:  Sci Adv       Date:  2021-03-03       Impact factor: 14.136

8.  Laser-Induced Graphene for Heartbeat Monitoring with HeartPy Analysis.

Authors:  Teodora Vićentić; Milena Rašljić Rafajilović; Stefan D Ilić; Bojana Koteska; Ana Madevska Bogdanova; Igor A Pašti; Fedor Lehocki; Marko Spasenović
Journal:  Sensors (Basel)       Date:  2022-08-23       Impact factor: 3.847

9.  Reflective oxygen saturation monitoring at hypothenar and its validation by human hypoxia experiment.

Authors:  Tao Guo; Zhengtao Cao; Zhengbo Zhang; Deyu Li; Mengsun Yu
Journal:  Biomed Eng Online       Date:  2015-08-05       Impact factor: 2.819

Review 10.  Advances in Photopletysmography Signal Analysis for Biomedical Applications.

Authors:  Jermana L Moraes; Matheus X Rocha; Glauber G Vasconcelos; José E Vasconcelos Filho; Victor Hugo C de Albuquerque; Auzuir R Alexandria
Journal:  Sensors (Basel)       Date:  2018-06-09       Impact factor: 3.576

  10 in total