Mammographic resolution: influence of focal spot intensity distribution and geometry.

E L Nickoloff1, E Donnelly, L Eve, J V Atherton, T Asch.   

Abstract

The influence of focal spot intensity distribution and geometry upon mammographic image quality were evaluated. The modulation transfer functions (MTF's) for eight different intensity distributions were determined and plotted in a manner to eliminate the effects of magnification and focal spot dimension. The results indicated that the total cross-sectional area is important for focal spots with uniform intensity distributions and equivalent diameters. For equivalent focal spot dimensions, intensity distributions with edge bands were shown to have less spatial resolution than uniform intensity distributions. Focal spots with greater intensities towards their centers provided better resolution than either uniform intensity distributions or distributions with edge bands for equivalent sizes. The type of intensity distribution was also shown to affect the accuracy of star pattern measurements of focal spot size; this method of measurement is only precise for a uniform square intensity distribution. Errors obtained with several other intensity distributions were tabulated. The variations of the effective focal spot size with position along the anode-cathode axis were shown to be of a factor of approximately two to three. The combined effects of geometric blur and film/screen blur were present for various heights above the cassette tray on several different mammographic systems.

Mesh:

Year:  1990        PMID: 2385201     DOI: 10.1118/1.596482

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Can electronic zoom replace magnification in mammography? A comparative Monte Carlo study.

Authors:  M Koutalonis; H Delis; A Pascoal; G Spyrou; L Costaridou; G Panayiotakis
Journal:  Br J Radiol       Date:  2010-07       Impact factor: 3.039

2.  Mammographic image denoising and enhancement using the Anscombe transformation, adaptive wiener filtering, and the modulation transfer function.

Authors:  Larissa C S Romualdo; Marcelo A C Vieira; Homero Schiabel; Nelson D A Mascarenhas; Lucas R Borges
Journal:  J Digit Imaging       Date:  2013-04       Impact factor: 4.056

3.  New automated fluoroscopic systems for pediatric applications.

Authors:  Zheng Feng Lu; Edward L Nickoloff; Carrie B Ruzal-Shapiro; James C So; Ajoy K Dutta
Journal:  J Appl Clin Med Phys       Date:  2005-11-21       Impact factor: 2.102

4.  Selective morphological analysis of cerium metal in electrodeposit recovered from molten LiCl-KCl eutectic by radiography and computed tomography.

Authors:  Young Taek Jee; Miran Park; Seungryong Cho; Jong-Il Yun
Journal:  Sci Rep       Date:  2019-02-04       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.