Literature DB >> 23849161

Do long leg supine CT scanograms correlate with weight-bearing full-length radiographs to measure lower limb coronal alignment?

H O Gbejuade1, P White2, M Hassaballa3, A J Porteous3, J R Robinson3, J R Murray3.   

Abstract

INTRODUCTION: The gold standard for measuring knee alignment is the lower limb mechanical axis (MA) using weight-bearing lower limb full-length x-ray (FLX). However, CT scanograms (CTS) are becoming increasingly popular in view of lower radiation exposure, speed of data acquisition and supine positioning. We compared the correlation and degree of agreement of knee joint coronal alignment using these two imaging modalities.
METHOD: From our series of complex primary and revision knee arthroplasty patients, we selected those with both FLX and CTS recorded onto digital PACS. The coronal alignments were assessed in 24 knees and the valgus/varus angles relative to the MA were measured. Results were analysed statistically using the paired samples t-test, Pearson's correlation coefficient, intra-class correlation coefficient, Cohen's kappa and Passing and Bablok regression to assess potential equality of methods.
RESULTS: The mean MA was 180.5° (165°-200°) for the CTS and 181° (164°-202°) for the FLX. The CTS MA angle data between the assessors were highly correlated (r=0.971, p <0.001) as were FLX MA angle measurements (r=0.988, p <0.001). 41.7% of the CTS and 37.5% of the FLX were in varus alignment, while 50% of the CTS and 43.8% of the FLX were in valgus alignment. Malalignment >5° was revealed by 18.8% of the CTS and 35.4% of the FLX.
CONCLUSION: Overall, good agreement was observed in MA angle data between the two imaging modalities, but reproducibility may be problematic. In the malaligned limb, weight-bearing FLX still remains a vital imaging modality. CTS should be used with caution in view of the under-detection of malalignment.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Alignment; CT scanogram; Knee; X-ray

Mesh:

Year:  2013        PMID: 23849161     DOI: 10.1016/j.knee.2013.05.009

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  11 in total

1.  Presence of rotational errors in long leg radiographs after total knee arthroplasty and impact on measured lower limb and component alignment.

Authors:  Günther Maderbacher; Clemens Baier; Achim Benditz; Ferdinand Wagner; Felix Greimel; Joachim Grifka; Armin Keshmiri
Journal:  Int Orthop       Date:  2017-01-31       Impact factor: 3.075

2.  A cadaver study comparing intraoperative methods to analyze lower limb alignment.

Authors:  Nael Hawi; Emmanouil Liodakis; Eduardo M Suero; Rupert Meller; Musa Citak; Christian Krettek
Journal:  Skeletal Radiol       Date:  2014-08-12       Impact factor: 2.199

Review 3.  [Partial replacement of the knee joint with patient-specific instruments and implants (ConforMIS iUni, iDuo)].

Authors:  J Beckmann; A Steinert; C Zilkens; A Zeh; C Schnurr; M Schmitt-Sody; M Gebauer
Journal:  Orthopade       Date:  2016-04       Impact factor: 1.087

4.  Clinical and radiographic outcomes of computer-navigated total knee arthroplasty are not adversely affected by body mass index.

Authors:  Ken Lee Puah; William Yeo; Mann Hong Tan
Journal:  J Orthop       Date:  2019-11-12

5.  Computed tomography scanogram compared to long leg radiograph for determining axial knee alignment.

Authors:  Thomas J Holme; Johann Henckel; Kai Hartshorn; Justin P Cobb; Alister J Hart
Journal:  Acta Orthop       Date:  2015-01-13       Impact factor: 3.717

6.  Reliability of an Integrated Ultrasound and Stereophotogrammetric System for Lower Limb Anatomical Characterisation.

Authors:  Frederick Greatrex; Erica Montefiori; Thomas Grupp; Josef Kozak; Claudia Mazzà
Journal:  Appl Bionics Biomech       Date:  2017-06-19       Impact factor: 1.781

7.  Accuracy of tibial positioning in the frontal plane: a prospective study comparing conventional and innovative techniques in total knee arthroplasty.

Authors:  R K Zahn; F Graef; J L Conrad; L Renner; C Perka; H Hommel
Journal:  Arch Orthop Trauma Surg       Date:  2020-03-02       Impact factor: 3.067

8.  WEIGHT-BEARING CONE BEAM CT SCANS AND ITS USES IN ANKLE, FOOT, AND KNEE: AN UPDATE ARTICLE.

Authors:  Carlos Felipe Teixeira Lôbo; Marcelo Bordalo-Rodrigues
Journal:  Acta Ortop Bras       Date:  2021 Mar-Apr       Impact factor: 0.513

9.  Primary osteoarthritic knees have more varus coronal alignment of the femur compared to young non-arthritic knees in a large cohort study.

Authors:  Elliot Sappey-Marinier; Cécile Batailler; John Swan; Matthieu Malatray; Laurence Cheze; Elvire Servien; Sébastien Lustig
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-06-01       Impact factor: 4.114

10.  Measurement of lower limb alignment: there are within-person differences between weight-bearing and non-weight-bearing measurement modalities.

Authors:  Daphne A L Schoenmakers; Peter Z Feczko; Bert Boonen; Martijn G M Schotanus; Nanne P Kort; Pieter J Emans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-07-18       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.