Literature DB >> 23841891

Influence of test technique on sensitization status of patients on the kidney transplant waiting list.

P Gombos1, G Opelz, S Scherer, C Morath, M Zeier, P Schemmer, C Süsal.   

Abstract

The exquisitely sensitive single antigen bead (SAB) technique was shown to detect human leukocyte antigen (HLA) antibodies in sera of healthy male blood donors. Such false reactions can have an impact on critical decisions, especially with respect to the determination of unacceptable HLA-antigen mismatches in patients awaiting a kidney transplant. We tested pretransplant sera of 534 patients on the kidney waiting list using complement-dependent cytotoxicity (CDC), enzyme-linked immunosorbent assay (ELISA) and SAB in parallel. Evidence of HLA antibodies was obtained in 5% of patients using CDC, 14% using ELISA, and 81% using SAB. Among patients without history of an immunizing event, 77% showed evidence of HLA antibodies in SAB. In contrast 98% of these patients were negative in ELISA and CDC. In patients without an immunizing event, SAB-detected antibodies reacted not always weakly but with mean fluorescence intensity (MFI) values as high as 14 440. High-MFI-value antibodies were found in some of these patients with HLA specificities that are rather common in general population, consideration of which would lead to unjustified exclusion of potential kidney donors. False SAB reactions can be unveiled by testing with additional antibody assays. Denial of donor kidneys to recipients based on HLA-antibody specificities detected exclusively in the SAB assay is not advisable. © Copyright 2013 The American Society of Transplantation and the American Society of Transplant Surgeons.

Entities:  

Keywords:  Antibody screening; HLA antibodies; kidney transplantation; single antigen beads; unacceptable HLA antigen mismatches

Mesh:

Substances:

Year:  2013        PMID: 23841891     DOI: 10.1111/ajt.12332

Source DB:  PubMed          Journal:  Am J Transplant        ISSN: 1600-6135            Impact factor:   8.086


  24 in total

1.  Conformational Variants of the Individual HLA-I Antigens on Luminex Single Antigen Beads Used in Monitoring HLA Antibodies: Problems and Solutions.

Authors:  Vadim Jucaud; Mepur H Ravindranath; Paul I Terasaki
Journal:  Transplantation       Date:  2017-04       Impact factor: 4.939

Review 2.  Acute and chronic antibody-mediated rejection in pediatric kidney transplantation.

Authors:  Lars Pape; Jan U Becker; Stephan Immenschuh; Thurid Ahlenstiel
Journal:  Pediatr Nephrol       Date:  2014-05-28       Impact factor: 3.714

3.  Pretransplantation monitoring of HLA antibodies by complement dependent cytotoxicity and Luminex-based assays.

Authors:  Nataša Katalinić; Marina Fućak; Tajana Crnić; Milena Ćurković; Alma Starčević; Sanja Balen
Journal:  Wien Klin Wochenschr       Date:  2016-10-14       Impact factor: 1.704

4.  The impact of screening method on HLA antibody detection before and after lung transplantation: A prospective pilot study.

Authors:  Severine Cao; Andrew M Courtwright; Anthony M Lamattina; Indira Guleria; Patrick Burkett; Souheil El-Chemaly; Hilary J Goldberg
Journal:  J Heart Lung Transplant       Date:  2017-11-22       Impact factor: 10.247

5.  Whether or not to accept a deceased donor kidney offer for a pediatric patient.

Authors:  Abanti Chaudhuri; Gerri James; Paul Grimm
Journal:  Pediatr Nephrol       Date:  2015-07-01       Impact factor: 3.714

Review 6.  Utility of HLA Antibody Testing in Kidney Transplantation.

Authors:  Ana Konvalinka; Kathryn Tinckam
Journal:  J Am Soc Nephrol       Date:  2015-03-24       Impact factor: 10.121

7.  Washing red cells after leucodepletion does not decrease human leukocyte antigen sensitization risk in patients with chronic kidney disease.

Authors:  Antony Aston; Rebecca Cardigan; Saber Bashir; Susan Proffitt; Helen New; Colin Brown; Ri Liesner; Sylvia Hennem; Helen Nulty; Olivia Shaw; Robert Vaughan; Jon Jin Kim; Lesley Rees
Journal:  Pediatr Nephrol       Date:  2014-04-29       Impact factor: 3.714

8.  Evidence to Support a Contribution of Polyreactive Antibodies to HLA Serum Reactivity.

Authors:  Baoshan Gao; Chunshu Rong; Fabrice Porcheray; Carolina Moore; Timothy C Girouard; Susan L Saidman; Waichi Wong; Yaowen Fu; Emmanuel Zorn
Journal:  Transplantation       Date:  2016-01       Impact factor: 4.939

Review 9.  Molecular assessment of disease states in kidney transplant biopsy samples.

Authors:  Philip F Halloran; Konrad S Famulski; Jeff Reeve
Journal:  Nat Rev Nephrol       Date:  2016-06-27       Impact factor: 28.314

10.  Exploring the cardiac response to injury in heart transplant biopsies.

Authors:  Philip F Halloran; Jeff Reeve; Arezu Z Aliabadi; Martin Cadeiras; Marisa G Crespo-Leiro; Mario Deng; Eugene C Depasquale; Johannes Goekler; Xavier Jouven; Daniel H Kim; Jon Kobashigawa; Alexandre Loupy; Peter Macdonald; Luciano Potena; Andreas Zuckermann; Michael D Parkes
Journal:  JCI Insight       Date:  2018-10-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.