Literature DB >> 2382842

Determination of physiological levels of glucose in an aqueous matrix with digitally filtered Fourier transform near-infrared spectra.

M A Arnold1, G W Small.   

Abstract

A procedure is described for the measurement of clinically relevant concentrations of glucose in aqueous solutions with near-infrared (NIR) absorbance spectroscopy. A glucose band centered at 4400 cm-1 is used for this analysis. NIR spectra are collected over the frequency range 5000-4000 cm-1 with a Fourier transform spectrometer. A narrow-band-pass optical interference filter is placed in the optical path of the spectrometer to eliminate light outside this restricted range. This configuration provides a 2.9-fold reduction in spectral noise by utilizing the dynamic range of the detector solely for light transmitted through the filter. In addition, a novel spectral processing scheme is described for extracting glucose concentration information from the resulting absorbance spectra. The key component of this scheme is a digital Fourier filter that removes both high-frequency noise and low-frequency base-line variations from the spectra. Numerical optimization procedures are used to identify the best location and width of a Gaussian-shaped frequency response function for this Fourier filter. A dynamic area calculation, coupled with a simple linear base-line correction, provides an integrated area from the processed spectra that is linearly related to glucose concentrations over the range 1-20 mM. The linear calibration model accurately predicted glucose levels in a series of test solutions with an overall mean percent error of 2.5%. Based on the uncertainty in the parameters defining the calibration model and the variability of the magnitudes of the integrated areas, an overall uncertainty of 7.8% was estimated for predicted glucose concentrations.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2382842     DOI: 10.1021/ac00213a021

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

Review 1.  Nanozyme-based colorimetric biosensor with a systemic quantification algorithm for noninvasive glucose monitoring.

Authors:  Hee-Jae Jeon; Hyung Shik Kim; Euiheon Chung; Dong Yun Lee
Journal:  Theranostics       Date:  2022-09-07       Impact factor: 11.600

2.  Simultaneous measurement of glucose and glutamine in aqueous solutions by near infrared spectroscopy.

Authors:  H Chung; M A Arnold; M Rhiel; D W Murhammer
Journal:  Appl Biochem Biotechnol       Date:  1995-02       Impact factor: 2.926

3.  Responses and calibration of amperometric glucose sensors implanted in the subcutaneous tissue of man.

Authors:  J C Pickup; D J Claremont; G W Shaw
Journal:  Acta Diabetol       Date:  1993       Impact factor: 4.280

4.  Development of FT-NIR models for the simultaneous estimation of chlorophyll and nitrogen content in fresh apple (Malus domestica) leaves.

Authors:  Elena Tamburini; Giuseppe Ferrari; Maria Gabriella Marchetti; Paola Pedrini; Sergio Ferro
Journal:  Sensors (Basel)       Date:  2015-01-26       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.