Literature DB >> 23822411

Critical assessment of intramodality 3D ultrasound imaging for prostate IGRT compared to fiducial markers.

Skadi van der Meer1, Esther Bloemen-van Gurp, Jolanda Hermans, Robert Voncken, Denys Heuvelmans, Carol Gubbels, Davide Fontanarosa, Peter Visser, Ludy Lutgens, Francis van Gils, Frank Verhaegen.   

Abstract

PURPOSE: A quantitative 3D intramodality ultrasound (US) imaging system was verified for daily in-room prostate localization, and compared to prostate localization based on implanted fiducial markers (FMs).
METHODS: Thirteen prostate patients underwent multiple US scans during treatment. A total of 376 US-scans and 817 matches were used to determine the intra- and interoperator variability. Additionally, eight other patients underwent daily prostate localization using both US and electronic portal imaging (EPI) with FMs resulting in 244 combined US-EPI scans. Scanning was performed with minimal probe pressure and a correction for the speed of sound aberration was performed. Uncertainties of both US and FM methods were assessed. User variability of the US method was assessed.
RESULTS: The overall US user variability is 2.6 mm. The mean differences between US and FM are: 2.5 ± 4.0 mm (LR), 0.6 ± 4.9 mm (SI), and -2.3 ± 3.6 mm (AP). The intramodality character of this US system mitigates potential errors due to transducer pressure and speed of sound aberrations.
CONCLUSIONS: The overall accuracy of US (3.0 mm) is comparable to our FM workflow (2.2 mm). Since neither US nor FM can be considered a gold standard no conclusions can be drawn on the superiority of either method. Because US imaging captures the prostate itself instead of surrogates no invasive procedure is required. It requires more effort to standardize US imaging than FM detection. Since US imaging does not involve a radiation burden, US prostate imaging offers an alternative for FM EPI positioning.

Entities:  

Mesh:

Year:  2013        PMID: 23822411     DOI: 10.1118/1.4808359

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  In vivo reproducibility of robotic probe placement for a novel ultrasound-guided radiation therapy system.

Authors:  Muyinatu A Lediju Bell; H Tutkun Sen; Iulian Iordachita; Peter Kazanzides; John Wong
Journal:  J Med Imaging (Bellingham)       Date:  2014-07-23

2.  Linearity of patient positioning detection : a phantom study of skin markers, cone beam computed tomography, and 3D ultrasound.

Authors:  Hendrik Ballhausen; Sheila Hieber; Minglun Li; Katia Parodi; Claus Belka; Michael Reiner
Journal:  Strahlenther Onkol       Date:  2015-01-30       Impact factor: 3.621

3.  Comparison of prostate positioning guided by three-dimensional transperineal ultrasound and cone beam CT.

Authors:  Minglun Li; Hendrik Ballhausen; Nina-Sophie Hegemann; Michael Reiner; Stefan Tritschler; Christian Gratzke; Farkhad Manapov; Stefanie Corradini; Ute Ganswindt; Claus Belka
Journal:  Strahlenther Onkol       Date:  2016-12-07       Impact factor: 3.621

4.  Evaluation of uterine ultrasound imaging in cervical radiotherapy; a comparison of autoscan and conventional probe.

Authors:  Mariwan Baker; David T Cooper; Claus F Behrens
Journal:  Br J Radiol       Date:  2016-07-25       Impact factor: 3.039

5.  3D dosimetric validation of ultrasound-guided radiotherapy with a dynamically deformable abdominal phantom.

Authors:  Charles K Matrosic; Wesley Culberson; Andrew Shepard; Sydney Jupitz; Bryan Bednarz
Journal:  Phys Med       Date:  2021-04-23       Impact factor: 2.685

6.  A comparative assessment of prostate positioning guided by three-dimensional ultrasound and cone beam CT.

Authors:  Minglun Li; Hendrik Ballhausen; Nina-Sophie Hegemann; Ute Ganswindt; Farkhad Manapov; Stefan Tritschler; Alexander Roosen; Christian Gratzke; Michael Reiner; Claus Belka
Journal:  Radiat Oncol       Date:  2015-04-09       Impact factor: 3.481

7.  Infections after fiducial marker implantation for prostate radiotherapy: are we underestimating the risks?

Authors:  Jasmin Loh; Katie Baker; Swetha Sridharan; Peter Greer; Chris Wratten; Anne Capp; Sarah Gallagher; Jarad Martin
Journal:  Radiat Oncol       Date:  2015-02-13       Impact factor: 3.481

8.  Determining intrafractional prostate motion using four dimensional ultrasound system.

Authors:  Mariwan Baker; Claus F Behrens
Journal:  BMC Cancer       Date:  2016-07-15       Impact factor: 4.430

9.  Three-dimensional surface and ultrasound imaging for daily IGRT of prostate cancer.

Authors:  Marco Krengli; Gianfranco Loi; Carla Pisani; Debora Beldì; Giuseppina Apicella; Valentina Amisano; Marco Brambilla
Journal:  Radiat Oncol       Date:  2016-12-13       Impact factor: 3.481

10.  Initial results for patient setup verification using transperineal ultrasound and cone beam CT in external beam radiation therapy of prostate cancer.

Authors:  Anne Richter; Bülent Polat; Ingulf Lawrenz; Stefan Weick; Otto Sauer; Michael Flentje; Frederick Mantel
Journal:  Radiat Oncol       Date:  2016-11-08       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.