Literature DB >> 23816114

Guidelines for sizing pericardium for aortic valve leaflet grafts.

Peter E Hammer1, Pedro J del Nido.   

Abstract

Surgical repair of the aortic valve with the use of leaflet grafts made from pericardium has been shown to be a viable option, particularly in children, in whom valve replacement has strong disadvantages. We present guidelines for sizing treated autologous pericardium to fabricate a leaflet graft for single-leaflet replacement. Both our clinical experience and experimental evidence indicate that effective repairs are best achieved by use of a semicircular graft with a diameter 10% to 15% greater than the sinotubular junction diameter in diastole. We also provide a simple formula to allow adjustment of these guidelines to account for variations in valve geometry and tissue properties.
Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23816114      PMCID: PMC3806098          DOI: 10.1016/j.athoracsur.2013.04.085

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  7 in total

1.  Geometric optimization of a tissue pattern for semilunar valve reconstruction.

Authors:  J G Hanlon; R W Suggit; E Gibbs; R M McMeeking; J W Love
Journal:  J Heart Valve Dis       Date:  1999-11

2.  Aortic valve replacement with autologous pericardium: surgical technique.

Authors:  C M Duran; R Gallo; N Kumar
Journal:  J Card Surg       Date:  1995-01       Impact factor: 1.620

3.  Reconstruction of the aortic valve with autologous pericardium: an experimental study.

Authors:  V C Gasparyan
Journal:  J Thorac Cardiovasc Surg       Date:  1999-01       Impact factor: 5.209

4.  Dimensions and geometric relationships of the human aortic valve as a function of pressure.

Authors:  M Swanson; R E Clark
Journal:  Circ Res       Date:  1974-12       Impact factor: 17.367

5.  Computational model of aortic valve surgical repair using grafted pericardium.

Authors:  Peter E Hammer; Peter C Chen; Pedro J del Nido; Robert D Howe
Journal:  J Biomech       Date:  2012-02-16       Impact factor: 2.712

6.  Aortic valve repair by cusp extension with the use of fresh autologous pericardium in children with rheumatic aortic insufficiency.

Authors:  A Kalangos; M Beghetti; A Baldovinos; D Vala; T Bichel; B Mermillod; N Murith; I Oberhansli; B Friedli; B Faidutti
Journal:  J Thorac Cardiovasc Surg       Date:  1999-08       Impact factor: 5.209

7.  Single cusp replacement for aortic regurgitation.

Authors:  Liang Tao; Xiang Jun Zeng; Yeong Phang Lim
Journal:  Ann Thorac Surg       Date:  2008-03       Impact factor: 4.330

  7 in total
  1 in total

Review 1.  Aortic valve repair update.

Authors:  Tatsuhiko Komiya
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-02-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.