Literature DB >> 23808568

Changes in functional visual acuity and ocular wavefront aberration after administration of eye ointment.

Takahiro Hiraoka1, Toshiya Yamamoto, Fumiki Okamoto, Tetsuro Oshika.   

Abstract

PURPOSE: To investigate the influence of an eye ointment on functional visual acuity (FVA) and ocular wavefront aberration.
METHODS: In 11 healthy volunteers (6 men and 5 women), visual function parameters, such as FVA, visual maintenance ratios (VMR), and minimal visual acuity (minVA), were assessed by the FVA measurement system before and 2, 5, 10, 20, 30, 40, 50, 60, 90, 120, 180, and 240 min after administration of ofloxacin eye ointment. Ocular aberration was also measured, and the root mean square (RMS) of second-, third-, fourth-, and total higher-order aberrations was determined. The time course of changes in each parameter was statistically analyzed by using repeated-measures analysis of variance and the Dunnett post hoc test, and relationships between visual function and ocular aberration parameters were also analyzed by the Pearson correlation test.
RESULTS: FVA, VMR, and minVA showed significant deteriorations at 2-, 5-, 10-, and 20 min after administration of eye ointment compared with the baseline values (P<0.05). All components of ocular wavefront aberration such as second-, third-, fourth-, and total higher-order RMS significantly increased at 2- and 5 min after the administration of eye ointment compared with the baseline values (P<0.05). In addition, deteriorations of these visual function parameters were significantly correlated with reduced blink numbers (Pearson's correlation coefficient; r=- 0.76, P=0.017 for FVA, r=0.79, P=0.013 for VMR, and r=-0.62, P=0.040 for minVA), and VMR was significantly related with changes in second-order RMS (r=-0.60, P=0.049).
CONCLUSIONS: Eye ointment significantly reduced visual function for at least 20 min. Especially, minVA was worse than 0.155 logMAR, which is legally required for driving, for 3 h after the administration. In addition, increases in lower-order aberration and low blink rates were associated with the degradation of visual function.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23808568     DOI: 10.1089/jop.2013.0024

Source DB:  PubMed          Journal:  J Ocul Pharmacol Ther        ISSN: 1080-7683            Impact factor:   2.671


  6 in total

1.  Comparison of two types of visual quality analyzer for the measurement of high order aberrations.

Authors:  Jing Hao; Lin Li; Fang Tian; Hong Zhang
Journal:  Int J Ophthalmol       Date:  2016-02-18       Impact factor: 1.779

2.  Influence of intraocular lens subsurface nanoglistenings on functional visual acuity.

Authors:  Takahiro Hiraoka; Kazunori Miyata; Takeshi Hayashidera; Masaharu Iida; Keita Takada; Keiichiro Minami; Tetsuro Oshika
Journal:  PLoS One       Date:  2017-03-22       Impact factor: 3.240

3.  Functional visual acuity after implantation of diffractive extended depth-of-focus intraocular lenses using an echelett optics.

Authors:  Toshihiro Sakisaka; Keiichiro Minami; Keita Takada; Yosai Mori; Kazunori Miyata
Journal:  BMC Ophthalmol       Date:  2021-12-05       Impact factor: 2.209

4.  Mesopic Functional Visual Acuity in Normal Subjects.

Authors:  Takahiro Hiraoka; Sujin Hoshi; Yoshifumi Okamoto; Fumiki Okamoto; Tetsuro Oshika
Journal:  PLoS One       Date:  2015-07-28       Impact factor: 3.240

5.  Shortened Measurement Time of Functional Visual Acuity for Screening Visual Function.

Authors:  Yuki Hidaka; Sachiko Masui; Yasuyo Nishi; Masahiko Ayaki; Minako Kaido; Masaru Mimura; Kazuo Tsubota; Kazuno Negishi
Journal:  J Ophthalmol       Date:  2019-09-10       Impact factor: 1.909

6.  Is it necessary to use tobramycin-dexamethasone eye ointment prophylactically in eyes at the end of intraocular surgery?

Authors:  Wei Zhang; Han Han; Kang Feng; Xiaohong Wang; Mei Du; Xiangda Meng; Yuanyuan Liu; Bo Huang; Rodrigo Brant; Hua Yan
Journal:  BMC Ophthalmol       Date:  2020-05-27       Impact factor: 2.209

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.