Literature DB >> 23803599

An assessment of lead eyewear in interventional radiology.

S McVey1, A Sandison, D G Sutton.   

Abstract

The International Commission on Radiological Protection (ICRP) has recently issued a proposal to reduce the occupational eye dose limit from 150 to 20 mSv. A series of experiments has been performed to determine the level of protection from scattered radiation afforded to the interventional radiology operator by protective lead glasses, taking into account variation in operator position and angle of head rotation. The lenses of the glasses have a lead equivalence of 0.75 mm lead with 0.5 mm lead present in the side shields. Our results have led us to propose the use of a general dose reduction factor of 5 when using eyewear with this lead equivalence and construction. We have also concluded that the forehead of the wearer provides the most robust position to site a dosemeter that will be used to estimate the dose to both eyes as part of a personal monitoring regime. We have confirmed that backscatter from the head itself is the limiting factor for the dose reduction potential of lead eyewear.

Entities:  

Mesh:

Year:  2013        PMID: 23803599     DOI: 10.1088/0952-4746/33/3/647

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  5 in total

1.  The importance of protection glasses during neuroangiographies: A study on radiation exposure at the lens of the primary operator.

Authors:  J B Tavares; E Sacadura-Leite; T Matoso; L L Neto; L Biscoito; J Campos; A Sousa-Uva
Journal:  Interv Neuroradiol       Date:  2016-02-02       Impact factor: 1.610

2.  Occupational radiation dose to eyes from interventional radiology procedures in light of the new eye lens dose limit from the International Commission on Radiological Protection.

Authors:  U O'Connor; C Walsh; A Gallagher; A Dowling; M Guiney; J M Ryan; N McEniff; G O'Reilly
Journal:  Br J Radiol       Date:  2015-03-11       Impact factor: 3.039

3.  Angular dependence of shielding effect of radiation protective eyewear for radiation protection of crystalline lens.

Authors:  Yuma Hirata; Toshioh Fujibuchi; Katsuya Fujita; Takayuki Igarashi; Eiji Nishimaru; Shogo Horita; Reiko Sakurai; Koji Ono
Journal:  Radiol Phys Technol       Date:  2019-10-15

4.  Personal Protective Equipment Availability and Utilization Among Interventionalists.

Authors:  André Rose; William Ian Duncombe Rae
Journal:  Saf Health Work       Date:  2018-10-10

Review 5.  Radiation protection of the eye lens in medical workers--basis and impact of the ICRP recommendations.

Authors:  Stephen Gr Barnard; Elizabeth A Ainsbury; Roy A Quinlan; Simon D Bouffler
Journal:  Br J Radiol       Date:  2016-02-01       Impact factor: 3.039

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.