Literature DB >> 23799977

Non-radiological method for three-dimensional implant position evaluation using an intraoral scan method.

Constantin von See1, Maximilian E H Wagner, Paul Schumann, Daniel Lindhorst, Nils-Claudius Gellrich, Marcus Stoetzer.   

Abstract

INTRODUCTION: This technical innovation presents a method that reproduces the position of a dental implant after insertion without the reuse of X-ray radiation.
MATERIAL AND METHODS: An implant was inserted into the natural gap between the canines and premolars of three domestic pigs. A Straumann Scanbody was then screwed to the implant, and a digital impression of the jaw segment was made. The scanbody was scanned using a hand-held scanner. This was followed by the radiological detection of implant position on a CBCT. On the computer, the position of the implant was calculated and compared with the radiologically detected position.
RESULTS: The calculated and determined position of the dental implant by the scanner is in good agreement with the radiologically controlled position. DISCUSSION: Evaluating the position of implants using intraoral scans is an easy and radiation-free method of three-dimensional site assessment after superimposition over a three-dimensional data set.
© 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  implant position; non-radiological determination; three-dimensional

Mesh:

Substances:

Year:  2013        PMID: 23799977     DOI: 10.1111/clr.12214

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  4 in total

Review 1.  Intraoral scanners in dentistry: a review of the current literature.

Authors:  Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo
Journal:  BMC Oral Health       Date:  2017-12-12       Impact factor: 2.757

2.  Standardization of three-dimensional pose of cylindrical implants from intraoral radiographs: a preliminary study.

Authors:  Saverio Cosola; Paolo Toti; Miguel Peñarrocha-Diago; Ugo Covani; Bruno Carlo Brevi; David Peñarrocha-Oltra
Journal:  BMC Oral Health       Date:  2021-03-06       Impact factor: 2.757

3.  Intraoral Digital Impressions for Virtual Occlusal Records: Section Quantity and Dimensions.

Authors:  Eneko Solaberrieta; Asier Garmendia; Aritza Brizuela; Jose Ramon Otegi; Guillermo Pradies; Andras Szentpétery
Journal:  Biomed Res Int       Date:  2016-01-10       Impact factor: 3.411

4.  Influence of bone condition on implant placement accuracy with computer-guided surgery.

Authors:  Ramadhan Hardani Putra; Nobuhiro Yoda; Masahiro Iikubo; Yoshihiro Kataoka; Kensuke Yamauchi; Shigeto Koyama; Upul Cooray; Eha Renwi Astuti; Tetsu Takahashi; Keiichi Sasaki
Journal:  Int J Implant Dent       Date:  2020-09-20