Literature DB >> 23798333

Feasibility of T2 -weighted turbo spin echo imaging of the human prostate at 7 tesla.

Marnix C Maas1, Eline K Vos, Miriam W Lagemaat, Andreas K Bitz, Stephan Orzada, Thiele Kobus, Oliver Kraff, Stefan Maderwald, Mark E Ladd, Tom W J Scheenen.   

Abstract

PURPOSE: To demonstrate that high quality T2 -weighted (T2w) turbo spin-echo (TSE) imaging of the complete prostate can be achieved routinely and within safety limits at 7 T, using an external transceive body array coil only.
METHODS: Nine healthy volunteers and 12 prostate cancer patients were scanned on a 7 T whole-body system. Preparation consisted of B0 and radiofrequency shimming and localized flip angle calibration. T1 and T2 relaxation times were measured and used to define the T2w-TSE protocol. T2w imaging was performed using a TSE sequence (pulse repetition time/echo time 3000-3640/71 ms) with prolonged excitation and refocusing pulses to reduce specific absorption rate.
RESULTS: High quality T2w TSE imaging was performed in less than 2 min in all subjects. Tumors of patients with gold-standard tumor localization (MR-guided biopsy or prostatectomy) were well visualized on 7 T imaging (n = 3). The number of consecutive slices achievable within a 10-g averaged specific absorption rate limit of 10 W/kg was ≥28 in all subjects, sufficient for full prostate coverage with 3-mm slices in at least one direction.
CONCLUSION: High quality T2w TSE prostate imaging can be performed routinely and within specific absorption rate limits at 7 T with an external transceive body array.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  7 Tesla; T2-weighted imaging; prostate; ultra-high field

Mesh:

Substances:

Year:  2013        PMID: 23798333     DOI: 10.1002/mrm.24818

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

Review 1.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

2.  First in-vivo human imaging at 10.5T: Imaging the body at 447 MHz.

Authors:  Xiaoxuan He; M Arcan Ertürk; Andrea Grant; Xiaoping Wu; Russell L Lagore; Lance DelaBarre; Yiğitcan Eryaman; Gregor Adriany; Eddie J Auerbach; Pierre-François Van de Moortele; Kâmil Uğurbil; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2019-12-17       Impact factor: 4.668

3.  Image quality and cancer visibility of T2-weighted magnetic resonance imaging of the prostate at 7 Tesla.

Authors:  E K Vos; M W Lagemaat; J O Barentsz; J J Fütterer; P Zámecnik; H Roozen; S Orzada; A K Bitz; M C Maas; T W J Scheenen
Journal:  Eur Radiol       Date:  2014-05-28       Impact factor: 5.315

Review 4.  Progress in Imaging the Human Torso at the Ultrahigh Fields of 7 and 10.5 T.

Authors:  Kamil Uğurbil; Pierre-Francois Van de Moortele; Andrea Grant; Edward J Auerbach; Arcan Ertürk; Russell Lagore; Jutta M Ellermann; Xiaoxuan He; Gregor Adriany; Gregory J Metzger
Journal:  Magn Reson Imaging Clin N Am       Date:  2021-02       Impact factor: 2.266

Review 5.  Novel methods for mapping the cavernous nerves during radical prostatectomy.

Authors:  Nathaniel M Fried; Arthur L Burnett
Journal:  Nat Rev Urol       Date:  2015-08       Impact factor: 14.432

6.  Hip imaging of avascular necrosis at 7 Tesla compared with 3 Tesla.

Authors:  J M Theysohn; O Kraff; N Theysohn; S Orzada; S Landgraeber; M E Ladd; T C Lauenstein
Journal:  Skeletal Radiol       Date:  2014-02-05       Impact factor: 2.199

Review 7.  Parallel transmission for ultrahigh-field imaging.

Authors:  Francesco Padormo; Arian Beqiri; Joseph V Hajnal; Shaihan J Malik
Journal:  NMR Biomed       Date:  2015-05-19       Impact factor: 4.044

8.  Design of a forward view antenna for prostate imaging at 7 T.

Authors:  Bart R Steensma; Ingmar Voogt; Abe J van der Werf; Cornelis A T van den Berg; Peter R Luijten; Dennis W J Klomp; Alexander J E Raaijmakers
Journal:  NMR Biomed       Date:  2018-07-18       Impact factor: 4.044

Review 9.  Evolution of UHF Body Imaging in the Human Torso at 7T: Technology, Applications, and Future Directions.

Authors:  M Arcan Erturk; Xiufeng Li; Pierre-Fancois Van de Moortele; Kamil Ugurbil; Gregory J Metzger
Journal:  Top Magn Reson Imaging       Date:  2019-06

10.  Comparing signal-to-noise ratio for prostate imaging at 7T and 3T.

Authors:  Bart R Steensma; Mariska Luttje; Ingmar J Voogt; Dennis W J Klomp; Peter R Luijten; Cornelis A T van den Berg; Alexander J E Raaijmakers
Journal:  J Magn Reson Imaging       Date:  2018-10-22       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.