Literature DB >> 23796804

Non-cryogenic ultra-low field MRI of wrist-forearm area.

I Savukov1, T Karaulanov, C J V Wurden, L Schultz.   

Abstract

Ultra-low field (ULF) MRI as an alternative to high field MRI can find some niche applications where high field is a liability. Previously we demonstrated hand images with a non-cryogenic ULF MRI system, but such a system was restrictive to the size of the imaging objects. We have modified the previous setup to increase the imaging volume and demonstrate the image of human hand near the wrist area. One goal for the demonstration is the evaluation of quality of larger bone structure to project image quality to other parts of extremities, such as elbows, shoulders, and knees. We found that after 12 min of acquisition, the image quality was quite satisfactory. To achieve this image quality, several problems were solved that appeared in the new system. The increase in the imaging volume size led to an increase in transient time and various measures were taken to reduce this time. We also explored a method of overcoming the artifacts and image quality reduction arising from field drifts present in the system due to heating of the coils. We believe that our results can be useful for evaluation of diagnostic capability of non-cryogenic ULF MRI of extremities and other parts of the body. The system can be also applied to image animals and tissues.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Alternative MRI; Anatomical; Imaging; Low-cost; Portable; Ultra-low field

Mesh:

Year:  2013        PMID: 23796804      PMCID: PMC3753084          DOI: 10.1016/j.jmr.2013.05.012

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  21 in total

1.  Magnetic resonance imaging with an optical atomic magnetometer.

Authors:  Shoujun Xu; Valeriy V Yashchuk; Marcus H Donaldson; Simon M Rochester; Dmitry Budker; Alexander Pines
Journal:  Proc Natl Acad Sci U S A       Date:  2006-08-02       Impact factor: 11.205

2.  Detection of NMR signals with a radio-frequency atomic magnetometer.

Authors:  I M Savukov; S J Seltzer; M V Romalis
Journal:  J Magn Reson       Date:  2006-12-23       Impact factor: 2.229

3.  MRI with an atomic magnetometer suitable for practical imaging applications.

Authors:  I M Savukov; V S Zotev; P L Volegov; M A Espy; A N Matlashov; J J Gomez; R H Kraus
Journal:  J Magn Reson       Date:  2009-05-03       Impact factor: 2.229

4.  The magnetic field dependence of proton spin relaxation in tissues.

Authors:  R G Bryant; D A Mendelson; C C Lester
Journal:  Magn Reson Med       Date:  1991-09       Impact factor: 4.668

5.  Microtesla MRI of the human brain combined with MEG.

Authors:  Vadim S Zotev; Andrei N Matlashov; Petr L Volegov; Igor M Savukov; Michelle A Espy; John C Mosher; John J Gomez; Robert H Kraus
Journal:  J Magn Reson       Date:  2008-06-21       Impact factor: 2.229

6.  Comparison of CT, low-field-strength MR imaging, and high-field-strength MR imaging. Work in progress.

Authors:  W W Orrison; G K Stimac; E A Stevens; D L LaMasters; M C Espinosa; L Cobb; F A Mettler
Journal:  Radiology       Date:  1991-10       Impact factor: 11.105

Review 7.  MRI: a charmed past and an exciting future.

Authors:  Albert Macovski
Journal:  J Magn Reson Imaging       Date:  2009-11       Impact factor: 4.813

Review 8.  MR equipment acquisition strategies: low-field or high-field scanners.

Authors:  L Martí-Bonmatí; M Kormano
Journal:  Eur Radiol       Date:  1997       Impact factor: 5.315

9.  Results of a prospective multicenter study for evaluation of the diagnostic quality of an open whole-body low-field MRI unit. A comparison with high-field MRI measured by the applicable gold standard.

Authors:  T Merl; M Scholz; P Gerhardt; M Langer; J Laubenberger; H D Weiss; H B Gehl; K J Wolf; I Ohnesorge
Journal:  Eur J Radiol       Date:  1999-04       Impact factor: 3.528

10.  Magnetic resonance diagnosis of the anterior labrum and capsule. Effect of field strength on efficacy.

Authors:  K H Allmann; O Walter; J Laubenberger; M Uhl; C H Buitrago-Tellez; N Biebow; M Langer
Journal:  Invest Radiol       Date:  1998-07       Impact factor: 6.016

View more
  4 in total

1.  Design of a mobile, homogeneous, and efficient electromagnet with a large field of view for neonatal low-field MRI.

Authors:  Steffen Lother; Steven J Schiff; Thomas Neuberger; Peter M Jakob; Florian Fidler
Journal:  MAGMA       Date:  2016-02-09       Impact factor: 2.310

2.  Multi-flux-transformer MRI detection with an atomic magnetometer.

Authors:  Igor Savukov; Todor Karaulanov
Journal:  J Magn Reson       Date:  2014-10-18       Impact factor: 2.229

3.  Low-Cost High-Performance MRI.

Authors:  Mathieu Sarracanie; Cristen D LaPierre; Najat Salameh; David E J Waddington; Thomas Witzel; Matthew S Rosen
Journal:  Sci Rep       Date:  2015-10-15       Impact factor: 4.379

4.  Fast Room Temperature Very Low Field-Magnetic Resonance Imaging System Compatible with MagnetoEncephaloGraphy Environment.

Authors:  Angelo Galante; Raffaele Sinibaldi; Allegra Conti; Cinzia De Luca; Nadia Catallo; Piero Sebastiani; Vittorio Pizzella; Gian Luca Romani; Antonello Sotgiu; Stefania Della Penna
Journal:  PLoS One       Date:  2015-12-02       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.