Abstract

OBJECTIVE: The aim of this study was to assess the efficacy and potential complications of a remote-controlled magnetic navigation system (Niobe II, Stereotaxis) for mapping and ablation of right or left ventricular outflow tract ventricular tachycardia or premature ventricular contractions.
METHODS: We studied 32 consecutive patients, mean age 43±11 years, 24 female. Mapping of the arrhythmia was performed using the CARTO RMT mapping system, remotely guided by the Niobe II. Radiofrequency ablation was performed at the site of earliest ventricular activation with pacemapping of at least 11/12 leads. Acute success was defined as suppression and non-inducibility of the arrhythmia after stimulation with isoprenaline. After a minimum 3-month follow-up, we assessed clinical success (absence of symptoms and suppression of the arrhythmia on Holter recording), defined as less than 50 premature ventricular contractions/24 hours.
RESULTS: The origin of the arrhythmia was in the right ventricular outflow tract in 28 patients (88%), in the left in three, and in the epicardium in one. Acute success was achieved in 26 patients (81%). Two patients underwent a second successful procedure, in one of which an epicardial approach was necessary. The overall clinical success rate, after two repeat procedures, was 88%. No complications occurred. There were two recurrences during a mean follow-up of 307±204 days.
CONCLUSION: The Niobe II remote control system for mapping and ablation of ventricular outflow tract arrhythmias is effective and safe, and provides precise mapping and a high success rate, with no complications.
Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

Entities:  

Keywords:  Ablação por radiofrequência; Estereotaxia; Extrassístoles ventriculares; Navegação magnética; Premature ventricular contractions; Radiofrequency ablation; Remote magnetic navigation; Stereotaxis; Taquicardia ventricular; Ventricular tachycardia

Mesh:

Year:  2013        PMID: 23790283     DOI: 10.1016/j.repc.2012.12.012

Source DB:  PubMed          Journal:  Rev Port Cardiol        ISSN: 0870-2551            Impact factor:   1.374


  7 in total

1.  Robotic navigation shows superior improvement in efficiency for atrial fibrillation ablation.

Authors:  Anna Maria Elisabeth Noten; Zsuzsanna Kis; Ferdi Akca; Rohit Bhagwandien; Sip Wijchers; Sing-Chien Yap; Tamas Szili-Torok
Journal:  J Atr Fibrillation       Date:  2019-02-28

2.  Feasibility of a novel mapping system combined with remote magnetic navigation for catheter ablation of premature ventricular contractions.

Authors:  Shipeng Dang; Christian Jons; Peter Karl Jacobsen; Steen Pehrson; Xu Chen
Journal:  J Arrhythm       Date:  2019-01-31

3.  Isolated diastolic potentials as predictors of success in ablation of right ventricular outflow tract idiopathic premature ventricular contractions.

Authors:  Leonor Parreira; Rita Marinheiro; Pedro Carmo; Pedro Amador; Dinis Mesquita; José Farinha; Diogo Cavaco; Rafael Jeronimo; Francisco Costa; Pedro Adragão
Journal:  PLoS One       Date:  2019-02-06       Impact factor: 3.240

4.  Prolonged Right Ventricular Outflow Tract Endocardial Activation Duration and Presence of Deceleration Zones in Patients With Idiopathic Premature Ventricular Contractions. Association With Low Voltage Areas.

Authors:  Leonor Parreira; Pedro Carmo; Rita Marinheiro; Dinis Mesquita; José Farinha; Ana Esteves; Pedro Amador; António Ferreira; Marta Fonseca; Rui Caria; Pedro Adragao
Journal:  Front Physiol       Date:  2021-07-02       Impact factor: 4.566

5.  Remote magnetic navigation vs. manual navigation for ablation of ventricular tachycardia: a meta-analysis.

Authors:  Y Wu; K-L Li; J Zheng; C-Y Zhang; X-Y Liu; Z-M Cui; Z-M Yu; R-X Wang; W Wang
Journal:  Neth Heart J       Date:  2015-09       Impact factor: 2.380

6.  Beyond catheter tip and radiofrequency lesion delivery: the role of robotics in ablation of ventricular tachycardia.

Authors:  L J de Vries; F Zijlstra; T Szili-Torok
Journal:  Neth Heart J       Date:  2015-09       Impact factor: 2.380

7.  Novel strategy of remote magnetic navigation-guided ablation for ventricular arrhythmias from right ventricle outflow tract.

Authors:  Yun Xie; Ao Liu; Qi Jin; Ning Zhang; Kangni Jia; Changjian Lin; Tianyou Ling; Kang Chen; Wenqi Pan; Liqun Wu
Journal:  Sci Rep       Date:  2020-10-20       Impact factor: 4.379

  7 in total