Literature DB >> 23771605

CT perfusion in acute stroke: know the mimics, potential pitfalls, artifacts, and technical errors.

Rajiv Mangla1, Sven Ekhom, Babak S Jahromi, Jeevak Almast, Manisha Mangla, Per-Lennart Westesson.   

Abstract

The CT perfusion (CTP) imaging of brain has been established as a clinically useful tool in multimodality imaging of acute stroke. All abnormalities seen on perfusion CT are not specifically related to acute infarct. There are many neurologic diseases causing symptoms simulating cerebrovascular disease produce an alteration of brain perfusion and thus can result in perfusion CT abnormalities. There are many pitfalls and artifacts in acquiring the data, calculation of maps and choosing arterial input function. We analyze and classify all these aspects, to allow the technician and the radiologist to know exactly what to avoid and what to choose, and we indicate the way to improve the quality of examination. The knowledge of mimics and pitfalls in acute stroke imaging can be helpful in accurate interpretation of these examinations.

Entities:  

Mesh:

Year:  2013        PMID: 23771605     DOI: 10.1007/s10140-013-1125-9

Source DB:  PubMed          Journal:  Emerg Radiol        ISSN: 1070-3004


  31 in total

1.  Quantitative cerebral blood flow measurement with dynamic perfusion CT using the vascular-pixel elimination method: comparison with H2(15)O positron emission tomography.

Authors:  Kohsuke Kudo; Satoshi Terae; Chietsugu Katoh; Masaki Oka; Tohru Shiga; Nagara Tamaki; Kazuo Miyasaka
Journal:  AJNR Am J Neuroradiol       Date:  2003-03       Impact factor: 3.825

2.  Perfusion CT in acute ischemic stroke: a qualitative and quantitative comparison of deconvolution and maximum slope approach.

Authors:  B Abels; E Klotz; B F Tomandl; S P Kloska; M M Lell
Journal:  AJNR Am J Neuroradiol       Date:  2010-06-25       Impact factor: 3.825

3.  Influence of partial volume on venous output and arterial input function.

Authors:  I van der Schaaf; E-J Vonken; A Waaijer; B Velthuis; M Quist; T van Osch
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

4.  CT perfusion imaging of acute stroke: the need for arrival time, delay insensitive, and standardized postprocessing algorithms?

Authors:  Angelos A Konstas; Michael H Lev
Journal:  Radiology       Date:  2010-01       Impact factor: 11.105

Review 5.  Early postischemic hyperperfusion: pathophysiologic insights from positron emission tomography.

Authors:  G Marchal; A R Young; J C Baron
Journal:  J Cereb Blood Flow Metab       Date:  1999-05       Impact factor: 6.200

6.  Acute stroke imaging research roadmap.

Authors:  Max Wintermark; Gregory W Albers; Andrei V Alexandrov; Jeffry R Alger; Roland Bammer; Jean-Claude Baron; Stephen Davis; Bart M Demaerschalk; Colin P Derdeyn; Geoffrey A Donnan; James D Eastwood; Jochen B Fiebach; Marc Fisher; Karen L Furie; Gregory V Goldmakher; Werner Hacke; Chelsea S Kidwell; Stephan P Kloska; Martin Köhrmann; Walter Koroshetz; Ting-Yim Lee; Kennedy R Lees; Michael H Lev; David S Liebeskind; Leif Ostergaard; William J Powers; James Provenzale; Peter Schellinger; Robert Silbergleit; Alma Gregory Sorensen; Joanna Wardlaw; Ona Wu; Steven Warach
Journal:  Stroke       Date:  2008-04-10       Impact factor: 7.914

7.  Estimation of cerebral blood flow through color duplex sonography of the carotid and vertebral arteries in healthy adults.

Authors:  M Schöning; J Walter; P Scheel
Journal:  Stroke       Date:  1994-01       Impact factor: 7.914

8.  The anterior cerebral artery is an appropriate arterial input function for perfusion-CT processing in patients with acute stroke.

Authors:  Max Wintermark; Benison C Lau; Jeffrey Chien; Sandeep Arora
Journal:  Neuroradiology       Date:  2007-12-05       Impact factor: 2.804

9.  FDA investigates the safety of brain perfusion CT.

Authors:  M Wintermark; M H Lev
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-05       Impact factor: 4.966

10.  Accuracy of CT cerebral perfusion in predicting infarct in the emergency department: lesion characterization on CT perfusion based on commercially available software.

Authors:  Chang Y Ho; Sajjad Hussain; Tariq Alam; Iftikhar Ahmad; Isaac C Wu; Darren P O'Neill
Journal:  Emerg Radiol       Date:  2013-01-16
View more
  10 in total

1.  Optimal Computed Tomographic Perfusion Scan Duration for Assessment of Acute Stroke Lesion Volumes.

Authors:  Aimen S Kasasbeh; Søren Christensen; Matus Straka; Nishant Mishra; Michael Mlynash; Roland Bammer; Gregory W Albers; Maarten G Lansberg
Journal:  Stroke       Date:  2016-11-15       Impact factor: 7.914

2.  Malignant cerebral edema after large anterior circulation infarction: a review.

Authors:  Allison E Arch; Kevin N Sheth
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-01

3.  A novel computed tomography perfusion-based quantitative tool for evaluation of perfusional abnormalities in migrainous aura stroke mimic.

Authors:  Antonio Granato; Laura D'Acunto; Miloš Ajčević; Giovanni Furlanis; Maja Ukmar; Roberta Antea Pozzi Mucelli; Paolo Manganotti
Journal:  Neurol Sci       Date:  2020-05-26       Impact factor: 3.307

4.  Perfusion CT in acute stroke: effectiveness of automatically-generated colour maps.

Authors:  Maja Ukmar; Ferruccio Degrassi; Roberta Antea Pozzi Mucelli; Francesca Neri; Fabio Pozzi Mucelli; Maria Assunta Cova
Journal:  Br J Radiol       Date:  2017-04       Impact factor: 3.039

5.  Reversible changes in diffusion- and perfusion-based imaging in cerebral venous sinus thrombosis.

Authors:  Ning Lin; Andrew K Wong; Lindsay J Lipinski; Maxim Mokin; Adnan H Siddiqui
Journal:  BMJ Case Rep       Date:  2015-02-12

6.  Use of CTA Test Dose to Trigger a Low Cardiac Output Protocol Improves Acute Stroke CTP Data Analyzed with RAPID Software.

Authors:  J B Hartman; S Moran; C Zhu; J Sharp; D S Hippe; D A Zamora; M Mossa-Basha
Journal:  AJNR Am J Neuroradiol       Date:  2022-02-17       Impact factor: 3.825

7.  CTP: Time for Patient-Tailored Acquisition Protocols.

Authors:  J Molad
Journal:  AJNR Am J Neuroradiol       Date:  2022-02-24       Impact factor: 3.825

8.  CT Perfusion: More Than What You Thought.

Authors:  J Molad
Journal:  AJNR Am J Neuroradiol       Date:  2021-01       Impact factor: 3.825

9.  Effect of extended CT perfusion acquisition time on ischemic core and penumbra volume estimation in patients with acute ischemic stroke due to a large vessel occlusion.

Authors:  Jordi Borst; Henk A Marquering; Ludo F M Beenen; Olvert A Berkhemer; Jan Willem Dankbaar; Alan J Riordan; Charles B L M Majoie
Journal:  PLoS One       Date:  2015-03-19       Impact factor: 3.240

10.  Characteristics of Misclassified CT Perfusion Ischemic Core in Patients with Acute Ischemic Stroke.

Authors:  Ralph R E G Geuskens; Jordi Borst; Marit Lucas; A M Merel Boers; Olvert A Berkhemer; Yvo B W E M Roos; Marianne A A van Walderveen; Sjoerd F M Jenniskens; Wim H van Zwam; Diederik W J Dippel; Charles B L M Majoie; Henk A Marquering
Journal:  PLoS One       Date:  2015-11-04       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.