Literature DB >> 23760744

How to measure wear following total hip arthroplasty.

Laura Grillini1, Saverio Affatato.   

Abstract

Total hip arthroplasty has yielded excellent results in decreasing pain and enhancing function in patients with hip degenerative disease. However, the problems associated with prosthetic failure and the consequent need for revision surgery still represent a major clinical issue. The most common reasons for revision surgery include implant loosening, periprosthetic osteolysis, infection, malalignment, stiffness, implant failure or fracture, and wear. The need for eliminating or reducing wear plays a crucial role in refining prosthesis composition and design. In this regard, it is important to develop new techniques for more accurate and reproducible measurement of wear. This should allow earlier detection of increased wear and thus permit earlier identification of patients who are at risk, and also help to identify faulty implant designs.
This work is aimed at discussing the most common in vivo and in vitro methods used for evaluating the wear of hip prosthesis components.

Entities:  

Mesh:

Year:  2013        PMID: 23760744     DOI: 10.5301/hipint.5000003

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  7 in total

1.  Micro X-Ray Computed Tomography Mass Loss Assessment of Different UHMWPE: A Hip Joint Simulator Study on Standard vs. Cross-Linked Polyethylene.

Authors:  Saverio Affatato; Filippo Zanini; Simone Carmignato
Journal:  PLoS One       Date:  2017-01-20       Impact factor: 3.240

2.  Quantification of Wear and Deformation in Different Configurations of Polyethylene Acetabular Cups Using Micro X-ray Computed Tomography.

Authors:  Saverio Affatato; Filippo Zanini; Simone Carmignato
Journal:  Materials (Basel)       Date:  2017-03-03       Impact factor: 3.623

3.  Wear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners.

Authors:  Saverio Affatato; Maria Cristina Valigi; Silvia Logozzo
Journal:  Materials (Basel)       Date:  2017-03-30       Impact factor: 3.623

4.  New Challenges in Tribology: Wear Assessment Using 3D Optical Scanners.

Authors:  Maria Cristina Valigi; Silvia Logozzo; Saverio Affatato
Journal:  Materials (Basel)       Date:  2017-05-18       Impact factor: 3.623

5.  Wear Behavior Characterization of Hydrogels Constructs for Cartilage Tissue Replacement.

Authors:  Saverio Affatato; Diego Trucco; Paola Taddei; Lorenzo Vannozzi; Leonardo Ricotti; Gilbert Daniel Nessim; Gina Lisignoli
Journal:  Materials (Basel)       Date:  2021-01-16       Impact factor: 3.623

6.  Finite Element Simulations of Hard-On-Soft Hip Joint Prosthesis Accounting for Dynamic Loads Calculated from a Musculoskeletal Model during Walking.

Authors:  Alessandro Ruggiero; Massimiliano Merola; Saverio Affatato
Journal:  Materials (Basel)       Date:  2018-04-09       Impact factor: 3.623

7.  Development of a Novel in Silico Model to Investigate the Influence of Radial Clearance on the Acetabular Cup Contact Pressure in Hip Implants.

Authors:  Saverio Affatato; Massimiliano Merola; Alessandro Ruggiero
Journal:  Materials (Basel)       Date:  2018-07-25       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.