Literature DB >> 23760176

Risk factors for failure of locked plate fixation of distal femur fractures: an analysis of 335 cases.

William M Ricci1, Philipp N Streubel, Saam Morshed, Cory A Collinge, Sean E Nork, Michael J Gardner.   

Abstract

OBJECTIVES: Locked plating has become a standard method to treat supracondylar femur fractures. Emerging evidence indicates that this method of treatment is associated with modest failure rates. The goals of this study were to determine risk factors for complications and to provide technical recommendations for locked plating of supracondylar femur fractures.
DESIGN: Retrospective review.
SETTING: Three level I or II trauma centers. PATIENTS/PARTICIPANTS: Three hundred twenty-six patients with 335 distal femur fractures (OTA 33A or C, 33% open) treated with lateral locked plates were studied. The average patient age was 57 years (range 17-97 years), 55% were women, 34% were obese, 19% were diabetic, and 24% were smokers. INTERVENTION: All patients were managed with open reduction internal fixation using a lateral distal femoral locked plate construct that included locked screws in the distal fragment and nonlocked, locked, or a combination of locked and nonlocked screws in the proximal fragment. MAIN OUTCOME MEASUREMENTS: Risk factors for reoperation to promote union, deep infection, and implant failure.
RESULTS: After the index procedure, 64 fractures (19%) required reoperation to promote union, including 30 that had a planned staged bone grafting because of the metaphyseal defect after debridement of an open fracture. Independent risk factors for reoperation to promote union and deep infection included diabetes and open fracture. Risk factors for proximal implant failure included open fracture, smoking, increased body mass index, and shorter plate length.
CONCLUSIONS: The identified risk factors for reoperation to promote union and complications included open fracture, diabetes, smoking, increased body mass index, and shorter plate length. Most factors are out of surgeon control but are useful when considering prognosis. Use of relatively long plates is a technical factor that can reduce risk for fixation failure. LEVEL OF EVIDENCE: Prognostic level II. See instructions for authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2014        PMID: 23760176     DOI: 10.1097/BOT.0b013e31829e6dd0

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  63 in total

1.  Dynamic locked plating for fixation of distal femur fractures using near- cortical over-drilling: Preliminary results of a prospective observational study.

Authors:  Sherif Galal
Journal:  J Clin Orthop Trauma       Date:  2017-07-15

2.  Outcomes of distal femur fractures treated with the Synthes 4.5 mm VA-LCP Curved Condylar Plate.

Authors:  Khang H Dang; Connor A Armstrong; Ravi A Karia; Boris A Zelle
Journal:  Int Orthop       Date:  2018-09-29       Impact factor: 3.075

3.  CORR Insights(®): Addition of a Medial Locking Plate to an In Situ Lateral Locking Plate Results in Healing of Distal Femoral Nonunions.

Authors:  Paul J Dougherty
Journal:  Clin Orthop Relat Res       Date:  2016-03-28       Impact factor: 4.176

4.  Distal Femur Locking Plate: The Answer to All Distal Femoral Fractures.

Authors:  Jagandeep Singh Virk; Sudhir Kumar Garg; Parmanand Gupta; Vivek Jangira; Jagdeep Singh; Sudhir Rana
Journal:  J Clin Diagn Res       Date:  2016-10-01

5.  Functional outcome of open distal femoral fractures managed with lateral locking plates.

Authors:  Deepak Jain; Raghav Arora; Rajnish Garg; Pankaj Mahindra; Harpal S Selhi
Journal:  Int Orthop       Date:  2019-05-24       Impact factor: 3.075

6.  The antegrade angle-stable locking intramedullary nail for type-C distal femoral fractures: a thirty four case experience.

Authors:  Zhihui Zhao; Yi Li; Kifayat Ullah; Basanta Sapkota; Hongbin Bi; Yongqing Wang
Journal:  Int Orthop       Date:  2018-02-03       Impact factor: 3.075

7.  The Use of Fibular Allograft in Complex Periarticular Fractures Around the Knee.

Authors:  Ashley E Levack; Naomi Gadinsky; Elizabeth B Gausden; Craig Klinger; David L Helfet; Dean G Lorich
Journal:  Oper Tech Orthop       Date:  2018-07-29

8.  Treatment of Distal Femur Nonunion Following Initial Fixation with a Lateral Locking Plate.

Authors:  Nabil A Ebraheim; Grant S Buchanan; Xiaochen Liu; Maxwell E Cooper; Nicholas Peters; Jacob A Hessey; Jiayong Liu
Journal:  Orthop Surg       Date:  2016-08       Impact factor: 2.071

Review 9.  [Operative therapy of fractures of the distal femur. Predictive factors for a complicated course].

Authors:  S Märdian; D Rau; P Schwabe; S Tsitsilonis; P Simon
Journal:  Orthopade       Date:  2016-01       Impact factor: 1.087

Review 10.  Locking plate fixation of distal femoral fractures is a challenging technique: a retrospective review.

Authors:  Giuseppe Toro; Giampiero Calabrò; Antonio Toro; Alessandro de Sire; Giovanni Iolascon
Journal:  Clin Cases Miner Bone Metab       Date:  2016-04-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.