Literature DB >> 23756744

A multicenter study of stent-assisted coiling of cerebral aneurysms with a Y configuration.

Kyle M Fargen1, J Mocco, Dan Neal, Michael C Dewan, John Reavey-Cantwell, Henry H Woo, David J Fiorella, Maxim Mokin, Adnan H Siddiqui, Aquilla S Turk, Raymond D Turner, Imran Chaudry, M Yashar S Kalani, Felipe Albuquerque, Brian L Hoh.   

Abstract

BACKGROUND: Stent-assisted coiling with 2 stents in a Y configuration is a technique for coiling complex wide-neck bifurcation aneurysms.
OBJECTIVE: We sought to provide long-term clinical and angiographic outcomes with Y-stent coiling, which are not currently established.
METHODS: Seven centers provided deidentified, retrospective data on all consecutive patients who underwent stent-assisted coiling for an intracranial aneurysm with a Y-stent configuration.
RESULTS: Forty-five patients underwent treatment by Y-stent coiling. Their mean age was 57.9 years. Most aneurysms were basilar apex (87%), and 89% of aneurysms were unruptured. Mean size was 9.9 mm. Most aneurysms were treated with 1 open-cell and 1 closed-cell stent (51%), with 29% treated with open-open stents and 16% treated with 2 closed-cell stents. Initial aneurysm occlusion was excellent (84% in Raymond grade I or II). Procedural complications occurred in 11% of patients. Mean clinical follow-up was 7.8 months, and 93% of patients had a modified Rankin Scale score of 0 to 2 at last follow-up. Mean angiographic follow-up was 9.8 months, and 92% of patients had Raymond grade I or II occlusion on follow-up imaging. Of those patients with initial Raymond grade III occlusion and follow-up imaging, all but 1 patient progressed to a better occlusion grade (83%; P < .05). Three aneurysms required retreatment because of recanalization (10%). There was no difference in initial or follow-up angiographic occlusion, clinical outcomes, incidence of aneurysm retreatment, or in-stent stenosis among open-open, open-closed, or closed-closed stent groups.
CONCLUSION: In a large multicenter series of Y-stent coiling for bifurcation aneurysms, there were low complication rates and excellent clinical and angiographic outcomes.

Entities:  

Mesh:

Year:  2013        PMID: 23756744     DOI: 10.1227/NEU.0000000000000015

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  28 in total

1.  LEO Baby Stent Use following Balloon-Assisted Coiling: Single- and Dual-Stent Technique--Immediate and Midterm Results of 29 Consecutive Patients.

Authors:  P Machi; V Costalat; K Lobotesis; C Ruiz; Y B Cheikh; O Eker; G Gascou; F Danière; C Riquelme; A Bonafé
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-13       Impact factor: 3.825

2.  Hybrid y stenting with the waffle-cone. A technical note.

Authors:  Nicola Limbucci; Sergio Nappini; Leonardo Renieri; Arturo Consoli; Andrea Rosi; Giovanni Grillea; Marcello Bartolo; Salvatore Mangiafico
Journal:  Interv Neuroradiol       Date:  2014-12-05       Impact factor: 1.610

Review 3.  The Past, Present and Future of Endovascular Aneurysm Treatment.

Authors:  H Henkes; W Weber
Journal:  Clin Neuroradiol       Date:  2015-06-02       Impact factor: 3.649

Review 4.  Neurosurgical management of aneurysms of the vertebrobasilar system: increasing indications for endovascular therapy with a continued role for open microneurosurgery.

Authors:  Anthony S Larson; Tapan Mehta; Andrew W Grande
Journal:  Neurosurg Rev       Date:  2021-01-06       Impact factor: 3.042

5.  Cerebral aneurysms treated with low-profile visualized intraluminal support device (LVIS Jr) Y-stent constructs: Technical experience with a single microcatheter technique.

Authors:  Colin Son; Paul Page; David Niemann
Journal:  Interv Neuroradiol       Date:  2019-12-18       Impact factor: 1.610

6.  The impact of stent design on the structural mechanics of the crossing Y-stent: an in vitro study.

Authors:  Chang-Young Lee; Seong-Ho Park; Chang-Hyun Kim; Goetz Benndorf
Journal:  Neuroradiology       Date:  2014-05-28       Impact factor: 2.804

7.  Usefulness of Non-Contrast-Enhanced MR Angiography Using a Silent Scan for Follow-Up after Y-Configuration Stent-Assisted Coil Embolization for Basilar Tip Aneurysms.

Authors:  N Takano; M Suzuki; R Irie; M Yamamoto; N Hamasaki; K Kamagata; K K Kumamaru; M Hori; H Oishi; S Aoki
Journal:  AJNR Am J Neuroradiol       Date:  2016-12-22       Impact factor: 3.825

8.  A New Window for the Treatment of Posterior Cerebral Artery, Superior Cerebellar Artery, and Basilar Apex Aneurysm: The Expanded Endoscopic Endonasal Approach.

Authors:  Ana M Lemos-Rodríguez; Satyan Sreenath; Ajay Unnithan; Vivian Doan; Pablo F Recinos; Adam Zanation; Deanna Sasaki-Adams
Journal:  J Neurol Surg B Skull Base       Date:  2015-12-02

9.  "Y" and "X" stent-assisted coiling of complex and wide-neck intracranial bifurcation aneurysms.

Authors:  B Bartolini; R Blanc; S Pistocchi; H Redjem; M Piotin
Journal:  AJNR Am J Neuroradiol       Date:  2014-07-24       Impact factor: 3.825

10.  Flow-Diverter Stents for the Treatment of Saccular Middle Cerebral Artery Bifurcation Aneurysms.

Authors:  J Caroff; H Neki; C Mihalea; F D'Argento; H Abdel Khalek; L Ikka; J Moret; L Spelle
Journal:  AJNR Am J Neuroradiol       Date:  2015-09-24       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.