BACKGROUND: Still today, measurements used as a reference in the cardiac magnetic resonance imaging have been obtained mainly from studies carried out in North-American and European populations. OBJECTIVE: To obtain measurements of the diastolic diameter, systolic diameter, end diastolic volume, end systolic volume, ejection fraction, and myocardial mass of the left and right ventricles in Brazilians. METHODS: 54 men and 53 women, with mean age of 43.4 ± 13.1 years, asymptomatic, with no cardiomyopathies, have been subjected to the cardiac magnetic resonance imaging, using a balanced steady state free precession technique. RESULTS: The averages and the standard deviations of the parameters for the left ventricle have been: diastolic diameter = 4.8 ± 0.5 cm; systolic diameter = 3.0 ± 0.6 cm; end diastolic volume = 128.4 ± 29.6 mL; end systolic volume = 45.2 ± 16.6 mL; ejection fraction = 65.5 ± 6.3%; mass = 95.2 ± 30.8 g. For the right ventricle, they have been: diastolic diameter = 3.9 ± 1.3 cm; systolic diameter = 2.5 ± 0.5 cm; end diastolic volume = 126.5 ± 30.7 mL; end systolic volume = 53.6 ± 18.4 mL; ejection fraction = 58.3 ± 8.0%, and mass = 26.1 ± 6.1 g. The masses and the volumes were significantly greater in the men, except for the end systolic volume of the left ventricle. The ejection fraction of the right ventricle has been significantly greater in the women. There has been a significant and inverted correlation of the systolic volume of the right volume with the progression of the age. CONCLUSION: This study has described, for the first time, cardiac measurements obtained through the cardiac magnetic resonance imaging in Brazilians, asymptomatic, with no cardiomyopathies, showing differences in accordance with gender and age.
BACKGROUND: Still today, measurements used as a reference in the cardiac magnetic resonance imaging have been obtained mainly from studies carried out in North-American and European populations. OBJECTIVE: To obtain measurements of the diastolic diameter, systolic diameter, end diastolic volume, end systolic volume, ejection fraction, and myocardial mass of the left and right ventricles in Brazilians. METHODS: 54 men and 53 women, with mean age of 43.4 ± 13.1 years, asymptomatic, with no cardiomyopathies, have been subjected to the cardiac magnetic resonance imaging, using a balanced steady state free precession technique. RESULTS: The averages and the standard deviations of the parameters for the left ventricle have been: diastolic diameter = 4.8 ± 0.5 cm; systolic diameter = 3.0 ± 0.6 cm; end diastolic volume = 128.4 ± 29.6 mL; end systolic volume = 45.2 ± 16.6 mL; ejection fraction = 65.5 ± 6.3%; mass = 95.2 ± 30.8 g. For the right ventricle, they have been: diastolic diameter = 3.9 ± 1.3 cm; systolic diameter = 2.5 ± 0.5 cm; end diastolic volume = 126.5 ± 30.7 mL; end systolic volume = 53.6 ± 18.4 mL; ejection fraction = 58.3 ± 8.0%, and mass = 26.1 ± 6.1 g. The masses and the volumes were significantly greater in the men, except for the end systolic volume of the left ventricle. The ejection fraction of the right ventricle has been significantly greater in the women. There has been a significant and inverted correlation of the systolic volume of the right volume with the progression of the age. CONCLUSION: This study has described, for the first time, cardiac measurements obtained through the cardiac magnetic resonance imaging in Brazilians, asymptomatic, with no cardiomyopathies, showing differences in accordance with gender and age.
Authors: Sandra Pujadas; Gautham P Reddy; Oliver Weber; Jennifer J Lee; Charles B Higgins Journal: J Magn Reson Imaging Date: 2004-06 Impact factor: 4.813
Authors: Carol J Salton; Michael L Chuang; Christopher J O'Donnell; Michelle J Kupka; Martin G Larson; Kraig V Kissinger; Robert R Edelman; Daniel Levy; Warren J Manning Journal: J Am Coll Cardiol Date: 2002-03-20 Impact factor: 24.094
Authors: Nikolay P Nikitin; Poay Huan Loh; Ramesh de Silva; Klaus K A Witte; Elena I Lukaschuk; Anita Parker; T Alan Farnsworth; Farqad M Alamgir; Andrew L Clark; John G F Cleland Journal: Int J Cardiol Date: 2006-03-22 Impact factor: 4.164
Authors: Diane E Bild; David A Bluemke; Gregory L Burke; Robert Detrano; Ana V Diez Roux; Aaron R Folsom; Philip Greenland; David R Jacob; Richard Kronmal; Kiang Liu; Jennifer Clark Nelson; Daniel O'Leary; Mohammed F Saad; Steven Shea; Moyses Szklo; Russell P Tracy Journal: Am J Epidemiol Date: 2002-11-01 Impact factor: 4.897
Authors: Nadine Kawel-Boehm; Scott J Hetzel; Bharath Ambale-Venkatesh; Gabriella Captur; Christopher J Francois; Michael Jerosch-Herold; Michael Salerno; Shawn D Teague; Emanuela Valsangiacomo-Buechel; Rob J van der Geest; David A Bluemke Journal: J Cardiovasc Magn Reson Date: 2020-12-14 Impact factor: 5.364
Authors: Zahra Raisi-Estabragh; Asmaa A M Kenawy; Nay Aung; Jackie Cooper; Patricia B Munroe; Nicholas C Harvey; Steffen E Petersen; Mohammed Y Khanji Journal: Eur Heart J Cardiovasc Imaging Date: 2021-04-28 Impact factor: 6.875